Airport Lighting Cable

Airport lighting cable, also known as a Type C airport cable, is a specific type of industrial cable used in airports to sustain runways.

Кабель VERI is a professional exporter of airfield lighting cables and special cables in China. Suppliers and airport cable manufacturers for a wide range of high-quality airport lighting cables to suit all kinds of applications. It is commonly the case that airfield lighting cables are required quickly and in small quantities. We use the latest technology available in our industry for the manufacturing of all airport lighting cables, which are now lighter, more durable, and more flexible. Our airfield lighting cables are manufactured to international standards with FAA, AC 150/5345-7E, and ICEA standards. The conductors of airport lighting cables are copper and aluminum.

Types of VERI Airport Lighting Cable

Запыт зараз

Faa-L-824 5kv 1X6mm2 8AWGAirport Ground Lighting Cable

VERI Airport Lighting Cable 5 кВ is used for power transmission from the power generator to the lighting and guiding light. In lighting system of the airport, is buried directly in the ground or installed in a duct buried in the ground, rated voltage of 5 кВ.

Дырыжор: Stranded bare or tinned copper.
Inner Semi-Conductor: Extruded semi-conducting compound.
Ізаляцыя: XLPE.
Outer Semi-Conductor: Semi-conducting tape or extruded.
Shield: Copper or brass tape(с). Tinned copper wire braid can be offered upon request.
Ножны: ПВХ. PE/XLPE can be offered upon request.

Dimensions and Weight

Будаўніцтва

няма. of Strand

Nominal Insulation Thickness

Nominal Overall Diameter

Nominal Weight

няма. x mm^2/ AWG

мм

мм

kg/km

1×6mm^2

7/19

2.3

11.0

180

1×8

7/19

2.3

14.3

298

1×6

7/19

2.3

15.4

366

1×4

7/19

2.3

17.0

513

TECHNICAL CHARACTERISTICS

Rated voltage: 5 кВ
Test voltage: 18 kV AC (5 minutes)
The maximum conductor temperature for normal operation is 90ºC
The maximum conductor temperature for short-circuit (5s maximum duration) is 250ºC
Continuous working current up to 20 A
Мінімальны радыус выгібу: 9 x D (Д: cable diameter)

APPLIED STANDARDS

FAA L-824 Type CANSI/NEMA WC 74/ICEA S-93-639-2012

Airfield lighting cable with shielded
Запыт зараз

Airport Ground Lighting Cables with shielded

ДАДЗЕНЫЯ airport lighting cables can be found in terminals and in airports all over the world. These cables are suitable for operation at 600v or 5kv in wet or dry locations. Conductors shall be annealed copper. The insulation layer of cables with different voltages is different.

Напрыклад, the insulation layer of 600v cable should be a black cross-linked polyethylene insulation layer that is wear-resistant, moisture-proof and heat-resistant. The 5kv cable shall have a 20 mil extruded XLPE conductor shield. The voltage of 5kv cables should have cross-linked polyethylene that is abrasion, moisture, heat and track resistant.

СТАНДАРТЫ&ЛІТАРАТУРА:МЭК 60502, МЭК 332-3, МЭК 60228, FAA AC 1 50/5345-7Э

  • Матэрыял правадніка: Bare or tinned copper
  • Conductor Type: Stranded
  • Insulation Material: Этыленпрапіленавы каўчук(EPR)
  • Shield: Tinned copper tape
  • Color: Green/Blue/Red/Grey/Black or as your requirements
  • Voltage: 5kv

APPLICATION​

Specifically designed for airport security and airport systems, airport ground lighting cables illuminate runways during take-off and landing approaches. These cables are suitable for stationary applications such as taxiways, runways, navigation aids, and obstacle lighting. It can be installed in a conduit and directly buried.

Unshielded airport lighting cable
Запыт зараз

5KV Airport Lighting Cable

Single conductor 5000-volt nonshielded power cables suitable for L-824 underground installation for lighting at airports per FAA L-824 Type C and AC 150/5345-53. Veri Cable offers a range of airports lighting cables from shield through to shielded, suitable for a range of primary and secondary circuits, available with PVC, Polyolefin, or HDPE sheathing. They are all XLPE insulated, providing a maximum operating temperature of 90 degrees. They are supplied with a voltage of 5kv.

СТАНДАРТЫ&ЛІТАРАТУРА:CEA S-96-659, NEMA WC71

  • Матэрыял правадніка: Bare or tinned copper
  • Conductor Type: Stranded
  • Insulation Material: Этыленпрапіленавы каўчук(EPR)
  • Color: Green/Blue/Red/Grey/Black or as your requirement
  • Voltage: 5kv

УЖЫВАННЕ

The type of unshielded airport lighting cable is primarily used for series lighting circuits for runways, control systems, and other multi-purpose installations. It can be used for direct burial, conduit, or raceway.

The above airfield ground lighting cables consist of standard supply cables covering a wide range of specific applications and environments. Our кабельная прадукцыя have been widely used in many airport buildings and airport runways. For more information about airport lighting cables, please contact us freely.

The Feature of Airport Lighting Cable

Airport lightning cable is flexible, lightweight, and fire-resistant in nature. The conductor can be of different materials of Aluminum/Copper. The airport lighting cables are semiconductive screened, which allows the cable to be safely operated continuously to the ground. In the cable industry, an insulator is a part that covers the conductor so that current cannot flow and cause any electrical failure. The insulator can be wire or any insulating material. PVC/XLPE insulation is responsible for a fire-resistant feature.

Airport lighting cables are built for usage in between the constant current source and the isolating transformers in the series lighting circuits. Particularly lighting sources such as runways, taxiways, navigational aids, and obstruction lighting. It is fitted for use in direct burial connections, pulled into metallic or non-metallic conduit.

Аб пасляпродажным абслугоўванні VERI Cable

ZMS Cable Order Shipment
Shipboard transportation of cables

Першы, Абавязацельства па якасці прадукцыі:

  1. Ёсць запісы якасці і дадзеныя выпрабаванняў для вытворчасці і выпрабаванняў усяго кабельная прадукцыя.
  2. Для праверкі прадукцыйнасці прадукту, мы шчыра запрашаем карыстальнікаў асабіста праверыць увесь працэс і прадукцыйнасць прадукту. Пасля пацверджання кваліфікацыі прадукту, ён будзе запакаваны і адпраўлены.

Па-другое, абавязацельствы па кошце прадукту:

  1. Для таго, каб забяспечыць высокую надзейнасць прадукту, выбар матэрыялу сістэмы вырабляецца з айчыннай або якаснай прадукцыі.
  2. На такіх жа конкурсных умовах, нашай кампаніі шчыра прадаставіць вам па даступнай цане без зніжэння тэхнічных характарыстык прадукту і змены кампанентаў прадукту.
  3. Абавязацельства па тэрміне дастаўкі:

Трэці, Час дастаўкі тавару:

Наколькі гэта магчыма ў адпаведнасці з патрабаваннямі карыстальніка, калі ёсць асаблівыя патрабаванні, якія неабходна выканаць загадзя, наша кампанія можа спецыяльна арганізаваць вытворчасць і мантаж, і імкнуцца задаволіць патрэбы карыстальнікаў.

Па-чацвёртае, абавязацельствы па пасляпродажным абслугоўванні:

  1. Прынцып службы: хутка, вырашальны, дакладны, прадуманы і грунтоўны.
  2. Мэты службы: якасць абслугоўвання, каб выйграць задавальненне кліента.
  3. Аператыўнасць абслугоўвання: Калі абсталяванне выходзіць з ладу ў межах гарантыйнага тэрміну або па-за яго, пасля паведамлення пастаўшчыка, абслугоўваючы персанал можа дабрацца да месца і пачаць тэхнічнае абслугоўванне 24 гадзіны.
  4. Прынцып абслугоўвання: Гарантыйны тэрмін эксплуатацыі кабельнай прадукцыі - дванаццаць месяцаў. На працягу гарантыйнага тэрміну, пастаўшчык бясплатна адрамантуе і заменіць дэталі, пашкоджаныя па меркаваннях якасці. Калі дэталі пашкоджаны па-за гарантыйным тэрмінам, прадастаўленыя аксэсуары спаганяюць толькі кошт пашкоджанняў абсталявання, выкліканых чалавечым фактарам пакупніка, і аксэсуары, адрамантаваныя або прадастаўленыя пастаўшчыком, разлічваюцца па сабекошце.

    Калі ласка, не саромейцеся адпраўляць свой запыт у форме ніжэй.