Armored Control Cable
Galvanized SWA Control Cable has the characteristics of moisture resistance, corrosion resistance, and damage resistance, and its excellent ability enables him to work normally in harsh conditions.
It can be laid in tunnels or cable trenches.
Ang steel wire armor layer of galvanized steel wire armored cable has high magnetic permeability and a good magnetic shielding effect.
It can be used to resist low-frequency interference and improve the anti-interference performance of the cable.
So this armored cable is suitable for industrial process automation applications, including instrument Cable, or signal transmission, measurement, control, and regulation.
Armored Control Cable Types
Galvanized Steel Braided Armored Control Cable
This product is manufactured according to the GB9330-88 standard. Ang low smoke low halogen flame retardant or low smoke zero halogen flame retardant control cable is manufactured according to the enterprise standard. The flame retardant property meets the requirements of GB / T17651 and GB / T17650. Flame-retardant control cables manufactured by corporate standards, flame retardant properties in line with GB / T18380.3 requirements.
This product is suitable for metallurgy, power, petrochemical, and other industrial and mining enterprises in the exchange rated voltage 450 / 750V and below electrical instrumentation, power distribution equipment, signal transmission, control, and measurement systems.
ype | Name | Applying bound |
KVV | Copper conductor PVC insulated and sheathed control cable | For laying indoors, in trenches, and in ducts for the fixed installation |
KVVP | Copper conductor PVC insulated & sheathed copper wire braiding screened control cable |
|
KVVP2 | Copper conductor PVC insulated and sheathed control cable with steel tape shied | For laying indoors, in trenches, and in ducts for the fixed installation |
KVV22 | Copper conductor PVC insulated and sheathed control cable with steel tape armored | For laying indoors, in trenches, in ducts, and in-ground, able to withstand heavier mechanical force, and for fixed installation |
KVVR | Copper conductor PVC insulated flexible control cable | For lying indoors, movable and flexible |
ZR-KVVP | Copper conductor PVC insulated & sheathed copper wire braiding screened flexible control cable | Fixed laying indoors with the capability of moving and screening |
ZR-KVV | Copper conductor PVC insulated and sheathed flame retardant control cable | For laying indoors, in trenches, in ducts, and for fixed installation. The cable should be flame retardant |
ZR-KVVP2 | Copper conductor PVC insulated and sheathed flame retardant control cable with steel tape shield | For laying indoors, in trenches, in ducts, and for fixed installation. The cable should be flame retardants |
ZR-KVV22 | Copper conductor PVC insulated and sheathed flame retardant control cable with steel tape armored | For laying indoors, in trenches, in ducts, and for fixed installation, the cable should be flame retardant and able to bear heavier external mechanical force and for fixed installation |
ZR-KVVR | Copper conductor PVC insulated and sheathed flame retardant flexible control cable | For laying indoors, the cable should be flame-retardant flexible, and movable |
USE REQUIREMENTS:
The max, long-term permitted operating temperature:70°C is for PVC insulated cable;80°C is for XLPE insulated cables. The laying temperature of cables should be not less than 0°C.
The allowable bending radius for cables: it should be not less than 6 times of outer diameter for non, armored or screened flexible cables, and it should be not less than 12 times of outer diameter for armored or copper tape screened cables.
Standard 600v Control Armored MC Power Cable
The product is suitable for connection in control, signal, protection circuit, and measuring system with rated power-frequency voltage 450/750V or 0.6/1KV.
CHARACTERISTICS:
1. The maximum permissible continuous operating temperature is 70℃
2. The lowest installation temperature of the cable is 0℃.
3. Permissible Min. Bending radius: not less than 6 times the completed cable diameter for unarmored cable; not less than 12 times the completed cable diameter for armored or copper tape screened cable; not less than 6 times the completed cable diameter for screened flexible cable.
FEATURES:
oil resistance、water resistance、abrasion resistance、acid and alkali resistance、various corrosive mass、aging resistance、non-combustion
The technical data of the standard teck90 600v control cable armored power cable MC cable is below for reference, any customized is available.
Type | Description | Main Application |
KYJV | Copper conductor XLPE insulated and PVC sheathed control cable | Laying indoors,in trenches, in ducts and directly in ground |
KYJVR | Copper conductor XLPE insulated and PVC sheathed | |
flexible control cable | ||
KYJVP | Copper conductor XLPE insulated and PVC sheathed control cable | Laying indoors,in trenches, in ducts directly in ground and other places that interference-resistance is requested. |
with copper tape lapping screen | ||
KYJVP2 | Copper conductor XLPE insulated and PVC sheathed flexible control | |
cable with braiding screen | ||
KYJVRP | Copper conductor XLPE insulated and PVC sheathed control cable | |
with copper tape longitudinal screen | ||
KYJVRP2 | Copper conductor XLPE insulated and PVC sheathed flexible control | |
cable with copper tape lapping screen |
KYJV22 | Copper conductor XLPE insulated and PVC sheathed control cable with steel tape armour | For flxed installation,laying indoors, in trenches and ducts,direkta in ground where heavier mechanical force withstood |
KYJV32 | Copper conductor XLPE insulated and PVC sheathed control cable | For laying indoor, in tunnels, ducts, conduit and direct burial etc. Permanent place, able to bear greater mechanical force |
with steel wire armour | ||
KYJVP2-22 | Copper conductor XLPE insulated and PVC sheathed steel tape armored control cable with copper tape lapping screen | For fixed installation,laying indoors,in trenches and ducts,directly in ground where heavier mechanical force and interference resistance withstood. |
About VERI Cable After-Sales Service
Una, Pagpasalig sa Kalidad sa Produkto:
- Adunay mga rekord sa kalidad ug datos sa pagsulay alang sa paghimo ug pagsulay sa tanan mga produkto sa cable.
- Alang sa inspeksyon sa performance sa produkto, kinasingkasing kaming nagdapit sa mga tiggamit sa pagsusi sa tibuok proseso ug performance sa produkto sa personal. Human mapamatud-an nga kuwalipikado ang produkto, kini iputos ug ipadala.
Ikaduha, ang pasalig sa presyo sa produkto:
- Aron masiguro ang taas nga pagkakasaligan sa produkto, ang materyal nga pagpili sa sistema gihimo sa mga domestic o taas nga kalidad nga mga produkto.
- Ubos sa parehas nga kondisyon sa kompetisyon, among kompanya will sincerely provide you at an affordable price without reducing the technical performance of the product or changing the product components.
- Delivery time commitment:
Ikatulo, Product delivery time:
As far as possible according to user requirements, if there are special requirements that need to be completed in advance, our company can specially organize production and installation, and strive to meet user needs.
Fourth, after-sales service commitment:
- Service tenet: fast, decisive, accurate, thoughtful and thorough.
- Service objectives: kalidad sa serbisyo aron makuha ang katagbawan sa kustomer.
- Episyente sa serbisyo: Kung ang kagamitan mapakyas sulod sa panahon sa warranty o sa gawas sa panahon sa warranty, human mapahibalo ang supplier, ang mga kawani sa pagmentinar makaabot sa site ug magsugod sa pagmentinar sa sulod 24 oras.
- Prinsipyo sa serbisyo: Ang panahon sa warranty sa mga produkto sa cable dose ka bulan. Sa panahon sa warranty, ang supplier mag-ayo ug mag-ilis sa mga bahin nga nadaot tungod sa kalidad nga mga hinungdan nga libre. Kung ang mga bahin nadaot sa gawas sa panahon sa warranty, the provided accessories will only charge the cost the cost of equipment damage caused by human factors of the buyer, and the accessories repaired or provided by the supplier are calculated at cost.