Instrumentation Cable
To date, VERI Cable has produced instrumentation cables for use in a variety of applications, including fully automated production, power equipment, tunnel lighting, or laying into cable trenches. The length of the cables sold reaches più chè 50,000 metri, and their resistance to moisture and corrosion is widely appreciated.
Instrumentation cables manufactured by VERI Cable are certified to GB, IEC, BS, ASTM, ISO900, ISO14000, ISO14001, ISO18000, BS, CE, IEC, NFC, ASTM and DIN.
CU/XLPE Insulated Instrument Cable---0.6/1KV
450/750v 0.5mm2 0.75mm2 1mm2 CU/XLPE insulated instrumentation cable
Custruzzione
Conduttore: Rame ricotto o stagnato
Accoppiamentu: Dui o trè cunduttori insulati uniformi torciati inseme cù una strata chì ùn supera micca 100 mm
Binder Tape: Nastro trasparente PETP
Standard
IEC 60502, BS 5308, GB 9330
Shielding | Braid |
Jacket/Insulation | PVC/XLPE/PE |
Tensione nominale | 600V |
Taglia | 0.5mm2-1000mm2 customizable |
Type | Low Voltage/Medium Voltage/High Voltage |
Certificate | ISO, CCC, CE, VDE |
Conductor Type | flexible |
Guaina | PVC Sheath |
Sheath Color | Black or blue |
Advantages:
Fire prevention, anti-impact, anti-rat, anti-mosquito, anti-radiation
Low working temperature
Strong overload resistance
Long service life, high safety, explosion-proof, corrosion resistance
High mechanical strength
Typically used in industrial process manufacturing plants for communications, data, and voice transmission of signals and services, and also for the interconnection of electrical equipment and instruments, usually in the oil industry.
Copper Tape Screened Twisted Pair Instrument Cable
1. Design: LSZH (Low Smoke Zero Halogen) Instrumentation cable consisting of bare copper conductors, neru & white, twisted pairs or black, white & red twisted triples with a continuous number sequence.
voltage test – 1500V, TECHNICAL DATA 0.5mm 1.5mm
Materiale cunduttore | Copper/copper aluminum tinned copper wire aluminum alloy |
Insulation Material | PVC/XLPE |
Shielding | Foil |
Jacket | PVC |
Color | all kinds of color is available |
Standard | IEC BS ASTM DIN GB9330-1998 |
Sectional area | 0.75 mm2 – 10 mm2 |
armored | steel tape steel wire |
Inner Sheath | LSZH (Low Smoke Zero Halogen) Guaina |
Outer Sheath | LSZH (Low Smoke Zero Halogen) Sheath is flame retardant, conforms to IEC60332-3-22, halogen-free, conforms to IEC60754-1, low smoke emissions, conforms to IEC61034-1-2 |
Conductor sizes | 0.5 mm² solid, 1.0 mm² solid, 0.5 mm² flexible, 0.75 mm² flexible or 1.5mm²stranded |
Collective screen | 24 µm aluminum / PETP tape over tinned copper drain wire, 0.5 mm² |
Underwater Instruments Flat Shaft Electrical Cable
This product can be used as an underwater communication cable. It can be either a single network cable structure a coaxial cable structure, a network cable plus multicore power cable, or a coaxial cable plus multicore control cable structure. The network cable is more than Category 5 or Category 6, and the video cable is commonly used as 75-3/75-5, ecc. This product can also be used as an underwater telephone line. When using it, you can choose 2 pairs to use as video recording lines, and you can choose any pair to use as a telephone line or as a communication cable. It is simple to use and convenient to maintain.
Conduttore | multi strand super fine stranded oxygen free copper wire |
Insulation Material | high-densitywaterproof material |
Shielding | tinned copper wire fabric |
Jacket | seawater resistant polyurethane |
Color | core wires are distinguished by different colors |
Network cable type | CAT5E/CAT6/CA6A |
tensile strength | 100/300/500KGcustomized |
Rated voltage | 300/300V |
Collective screen | 24 µm aluminium / PETP tape over tinned copper drain wire, 0.5 mm² |
Water depth | 100M/200m/500m, ecc |
Bending radius of zero buoyancy steel wire mesh:
Fixed installation: 5 × Cable outer diameter (D)
Mobile installation: When the strokeis<10m, the bending radius is 7.5 × D When the stroke is ≥ 10m, the bending radius is 10 × D
Instrument Cable Installation and Wiring Tips
- —Under the eaves. Standard cables can be used only if the cable is not exposed to direct sunlight or extreme heat, and conduit is recommended. Do not use cables without UV protection in direct sunlight.
- —On the outer wall. Avoid direct sunlight on the wall and man-made damage. Heating cables are exposed to high temperatures in metal conduit or trunking, and many polymeric materials experience reduced service life at these temperatures.
- —In pipes (plastic or metal). If in pipes, pay attention to the damage to plastic pipes and the heat conduction of metal pipes. Once mechanical damage occurs, fiber optic cables are expensive to repair, requiring at least two terminations at each discontinuity point.
- —Suspended applications/overhead cables. Consider cable sag and stress. The cable is exposed to direct sunlight or not.
- —Directly laying in the underground cable trench, this environment is the smallest control range. The installation of the cable trench should be checked regularly for dryness or dampness. If the shield of the control cable needs to be grounded, the appropriate standards must be followed.
VERI Transportation with Professional Service
VERI Cable hà parechje manere di prutezzione di i vostri cavi, cun imballaggio di spedizione robusta è prufessiunale è assicurazione cumpleta. Prima di spedizione, our cables are packaged in wooden reels and corrugated box coils. Durante u trasportu, per prutege l'estremità di u cable da l'umidità, li sigillamu cù cinta autoadesiva BOPP è non-hygroscopic.
Se ci sò prublemi di qualità, cum'è l'imballaggio dannighjatu è i danni di a superficia di u produttu in u locu quandu i merchenzie sò ricevuti, se i beni sò cunfirmati per esse veru, i beni ùn currispondenu à l'ordine, è i prublemi di qualità truvati da u cliente durante a stallazione, u prucessu di posa è usu sò cunfirmati per esse i prublemi di qualità di u pruduttu stessu, Se a consegna ùn hè micca in cunfurmità cù i requisiti di u cuntrattu, per piacè cuntattate a nostra cumpagnia direttamente.