Concentric & Split Cable
Concentric Cables are composed of single-core or multicore conductors, and there is an insulation layer between the multiple conductors, which can effectively prevent electromagnetic interference between the two conductors.
VERI produced Concentric Cables are typical of most cable insulation types. Concentric cables are often used as energy supply cables. Most common in power distribution, panel, and street lighting areas.
Concentric Cable Popular Models
LV Concentric Cable
Conduttore: Copper Class 2
Insulazione: XLPE / PVC
Core: Single Core
Cable Inner Sheath: PVC
Concentric Conductor Layer: Copper
Cable Tape: No-absorbent material or OEM
Armored: AWA
Cable Outer Sheath: XLPE / PVC / PE / LSZH
Aluminum MV Concentric Cable
Standard: ASTM-B; ASTM-D; UL
Conduttore: 8000 Series Aluminum Alloy
Insulazione: XLPE / PVC
Core: Single Core
Cable Inner Sheath: PVC
Concentric Conductor Layer: Alluminiu
Cable Tape: No-absorbent material or OEM
Armored: AWA
Cable Outer Sheath: XLPE / PVC / PE / LSZH
LSZH Split Concentric Cable
Conduttore: Alluminiu / Copper Conductor
Insulazione: XLPE
Core: Single / Two / Three / Four core
Cable Inner Sheath: PVC
Concentric Conductor Layer: Copper / Alluminiu
Cable Tape: No-absorbent Material or OEM
Cable Outer Sheath: LSZH
Three/Four Core Concentric Cable
Conduttore: Alluminiu / Copper Conductor
Insulazione: XLPE
Core: Three / Four core
Cable Inner Sheath: PVC
Concentric Conductor Layer: Copper/Aluminum
Cable Tape: No-absorbent Material or OEM
Cable Outer Sheath: XLPE / PVC / PE
Cable Application
This copper/aluminum conductor concentric cable is used in power distribution lines of rated voltage 600/1000V and below as the connecting cable from the power source to the electricity meter. Concentric conductor cables are suitable for use in dry and wet locations, directly underground or outdoors. The maximum working temperature is 70°C (PVC or PE insulation) or 90°C (XLPE insulation).
Armored concentric conductor cables have better mechanical strength. When buried in the ground, this increases their ability to withstand stresses, reduces damage caused by external forces, and ensures that cables and linked equipment work efficiently.
Cable Specifications
Number of cores: 1, 2, 3, 3+1, 3+2, 4, 4+1, 5 eccetera.
Tipu | Taglia | Custruzzione | |||||
AWG | Phase Conductor | XLPE(mm) | Neutral Conductor | UV-PVC(mm) | |||
No. | Dia. | Thick | No. | Dia. | Thick | ||
Bipolar | 12 | 7 | 0.78 | 1.14 | 39 | 0.321 | 1.14 |
10 | 7 | 0.98 | 1.14 | 25 | 0.511 | 1.14 | |
8 | 7 | 1.23 | 1.14 | 25 | 0.643 | 1.14 | |
6 | 7 | 1.55 | 1.14 | 25 | 0.813 | 1.14 | |
4 | 7 | 1.96 | 1.14 | 27 | 1.02 | 1.14 | |
Tripolar | 8 | 7 | 1.23 | 1.14 | 65 | 0.45 | 1.14 |
6 | 7 | 1.55 | 1.14 | 65 | 0.511 | 1.52 | |
4 | 7 | 1.96 | 1.14 | 65 | 0.643 | 1.52 | |
2 | 7 | 2.47 | 1.14 | 65 | 0.823 | 1.52 |
Tipu | Taglia | Custruzzione | |||||
mm2 | Phase Conductor | XLPE(mm) | Neutral Conductor | UV-PVC(mm) | |||
No. | Dia. | Thick | No. | Dia. | Thick | ||
Bipolar | 10 | 7 | 1.35 | 1.2 | 13 | 0.98 | 1.0 |
6 | 7 | 1.1 | 1.2 | 18 | 0.654 | 1.0 |
If you don’t know how to choose the products you need or don’t find the cable type and size you need on this page, don’t worry. Cuntattateci è mandateci i vostri bisogni, and we can help you choose the right cable. Pudete furnisce l'infurmazioni seguenti: tensione di cable, conductor material, materiale d'insulazione è guaina, tipu di scudo, tipu d'armatura, ecc. o ci ponu furnisce un ambiente di stallazione di cable, esigenze di applicazione, ecc. Vi serviremu di tuttu u core. VERI Cable Supplier has a number of quality certifications: ISO 9000, ISO 9001, ISO14000, ISO14001, ISO18000, CE, IEC, BS, NFC, ASTM, DA, ecc.
Excellent service de VERI Cable
VERI Cable hà parechje manere di prutezzione di i vostri cavi, cun imballaggio di spedizione robusta è prufessiunale è assicurazione cumpleta. Prima di spedizione, i nostri cavi sò imballati in bobine di legnu è bobine di scatula ondulata. Durante u trasportu, per prutege l'estremità di u cable da l'umidità, li sigillamu cù cinta autoadesiva BOPP è non-hygroscopic.
Se ci sò prublemi di qualità, cum'è l'imballaggio dannighjatu è i danni di a superficia di u produttu in u locu quandu i merchenzie sò ricevuti, se i beni sò cunfirmati per esse veru, i beni ùn currispondenu à l'ordine, è i prublemi di qualità truvati da u cliente durante a stallazione, u prucessu di posa è usu sò cunfirmati per esse i prublemi di qualità di u pruduttu stessu, Se a consegna ùn hè micca in cunfurmità cù i requisiti di u cuntrattu, per piacè cuntattate a nostra cumpagnia direttamente.