The Voltage Rating Coaxial Ground Cable

The voltage level of the coaxial grounding cable should be determined according to the induced potential of the cable line. According to the past design experience, the voltage level of the coaxial grounding cable is generally 10kV; the cross-section of the coaxial grounding cable should be strictly selected according to the grounding current of the cable line. Gayunpaman, in actual work, due to the lack of data and the complexity of calculation. The main models are VOV, YJOV, and YOY.

Scope of Use

High-voltage cables are designed according to single-loop, double-loop, or even more loops. If the length of a single cable is longer, the induced potential will be larger. It is best not to exceed 50v, iyon ay, the voltage of 50 volts without protection devices. But if there are protective devices, such as return lines, coaxial cables, atbp., it should not exceed 300v.

The coaxial grounding cable is generally used for the lead wire of the arrester and the grounding wire of the lightning protection, and the grounding box of the line sheath insulation protection device of the cross-linked cable is connected. Impedance, coaxial ground cables have low impedance characteristics for transients.

VOV (YOV YJOV) is generally used for cross-connection of high-voltage cables to reduce the induced potential of the metal sheath. The protection box used for the 110KV~220KV cross-linked cable line sheath insulation protection device is connected with the transposition box. It is used for ground connection in transmission and distribution lines, and connection in cross-connect boxes. The inner and outer conductors of the coaxial cable are connected reasonably and conveniently and are reliable in use.

Conditions of Use

1. The maximum allowable working temperature of the conductor: is 90℃.

2. The bending radius is not less than 20 times the outer diameter of the cable.

3. The ambient temperature should not be lower than 0℃ when laying the coaxial grounding power cable.

4. The power frequency rated voltage 8.7/10KV transmission and distribution line (110kv ~ 220KV) is grounded.

5. The connection wire between the metal sheath of the cable or the voltage limiter of the shielding layer shall meet the following requirements: Una, the connecting line should be the shortest, and coaxial cable should be used above 3m. Pangalawa, the insulation level of the connecting wire shall not be less than the insulation level of the outer sheath of the cable. Thirdly, the cross-section of the connecting line should meet the thermal stability requirements when the single-phase grounding fault current of the system passes through.

ZMS Cable F

Recent Posts

Ano ang Layunin ng Mineral Insulated Cables? Pagmimina Lamang?

Kapag naririnig ng mga tao ang term na mineral insulated cable, many immediately think of harsh environments like

2 months ago

Madaling Pag-aaral —— ADSS Cable Installation Step-by-Step Guide para sa Mga Nagsisimula

Habang ang mga network ng telekomunikasyon at mga sistema ng paghahatid ng kuryente ay mabilis na lumalaki, the demand for reliable and cost-effective

3 months ago

Harapin! Anong mga pang-industriya na kable ang kailangan sa isang malaking proyekto ng langis at gas?

Sa malalaking proyekto ng langis at gas, Ang mga pang-industriya na kable ay hindi lamang mga aksesorya—they are the "nervous

3 months ago

Ang Pinaka Kumpletong Mga Uri ng Cable Lugs - Halika at Piliin Kung Ano ang Kailangan Mo!

Sa mundo ng mga koneksyon sa kuryente, Mga Cable Lugs—Kilala rin bilang cable ears o cable terminals—are

3 months ago

Ano ang pagkakaiba sa pagitan ng H05RR-F & H05RN-F & H07RN-F sa Rubber Cable?

Pagpili ng Tamang Cable ng Goma para sa isang Proyekto sa Electrical Engineering, it is critical to

3 months ago

Maligayang Bagong Taon ng Tsino! —— ZMS Cable

Dear partners and customers: January 29th, 2025 is the Chinese Lunar New YearSpring

5 months ago