CÂBLE DE COMMANDE BLINDÉ
Galvanized SWA Control Cable has the characteristics of moisture resistance, résistance à la corrosion, and damage resistance, and its excellent ability enables him to work normally in harsh conditions.
It can be laid in tunnels or cable trenches.
Le steel wire armor layer of galvanized steel wire armored cable has high magnetic permeability and a good magnetic shielding effect.
It can be used to resist low-frequency interference and improve the anti-interference performance of the cable.
So this armored cable is suitable for industrial process automation applications, including instrument Cable, or signal transmission, measurement, control, and regulation.
Armored Control Cable Types
Galvanized Steel Braided Armored Control Cable
This product is manufactured according to the GB9330-88 standard. The low smoke low halogen flame retardant or low smoke zero halogen flame retardant control cable is manufactured according to the enterprise standard. The flame retardant property meets the requirements of GB / T17651 and GB / T17650. Flame-retardant control cables manufactured by corporate standards, flame retardant properties in line with GB / T18380.3 requirements.
This product is suitable for metallurgy, power, petrochemical, and other industrial and mining enterprises in the exchange rated voltage 450 / 750V and below electrical instrumentation, power distribution equipment, transmission de signaux, control, and measurement systems.
ype | Name | Applying bound |
KVV | Copper conductor PVC insulated and sheathed control cable | For laying indoors, in trenches, and in ducts for the fixed installation |
KVVP | Copper conductor PVC insulated & sheathed copper wire braiding screened control cable |
|
KVVP2 | Copper conductor PVC insulated and sheathed control cable with steel tape shied | For laying indoors, in trenches, and in ducts for the fixed installation |
KVV22 | Copper conductor PVC insulated and sheathed control cable with steel tape armored | For laying indoors, in trenches, in ducts, and in-ground, able to withstand heavier mechanical force, and for fixed installation |
KVVR | Copper conductor PVC insulated flexible control cable | For lying indoors, movable and flexible |
ZR-KVVP | Copper conductor PVC insulated & sheathed copper wire braiding screened flexible control cable | Fixed laying indoors with the capability of moving and screening |
ZR-KVV | Copper conductor PVC insulated and sheathed flame retardant control cable | For laying indoors, in trenches, in ducts, and for fixed installation. The cable should be flame retardant |
ZR-KVVP2 | Copper conductor PVC insulated and sheathed flame retardant control cable with steel tape shield | For laying indoors, in trenches, in ducts, and for fixed installation. The cable should be flame retardants |
ZR-KVV22 | Copper conductor PVC insulated and sheathed flame retardant control cable with steel tape armored | For laying indoors, in trenches, in ducts, and for fixed installation, the cable should be flame retardant and able to bear heavier external mechanical force and for fixed installation |
ZR-KVVR | Copper conductor PVC insulated and sheathed flame retardant flexible control cable | For laying indoors, the cable should be flame-retardant flexible, and movable |
USE REQUIREMENTS:
The max, long-term permitted operating temperature:70°C is for PVC insulated cable;80°C is for XLPE insulated cables. The laying temperature of cables should be not less than 0°C.
The allowable bending radius for cables: it should be not less than 6 times of outer diameter for non, armored or screened flexible cables, and it should be not less than 12 times of outer diameter for armored or copper tape screened cables.
Standard 600v Control Armored MC Power Cable
The product is suitable for connection in control, signal, protection circuit, and measuring system with rated power-frequency voltage 450/750V or 0.6/1KV.
CHARACTERISTICS:
1. The maximum permissible continuous operating temperature is 70℃
2. The lowest installation temperature of the cable is 0℃.
3. Permissible Min. Rayon de courbure: not less than 6 times the completed cable diameter for unarmored cable; not less than 12 times the completed cable diameter for armored or copper tape screened cable; not less than 6 times the completed cable diameter for screened flexible cable.
FEATURES:
oil resistance、résistance à l'eau、abrasion resistance、acid and alkali resistance、various corrosive mass、aging resistance、non-combustion
The technical data of the standard teck90 600v control cable armored power cable MC cable is below for reference, any customized is available.
Taper | Description | Main Application |
KYJV | Copper conductor XLPE insulated and PVC sheathed control cable | Laying indoors,in trenches, in ducts and directly in ground |
KYJVR | Copper conductor XLPE insulated and PVC sheathed | |
flexible control cable | ||
KYJVP | Copper conductor XLPE insulated and PVC sheathed control cable | Laying indoors,in trenches, in ducts directly in ground and other places that interference-resistance is requested. |
with copper tape lapping screen | ||
KYJVP2 | Copper conductor XLPE insulated and PVC sheathed flexible control | |
cable with braiding screen | ||
KYJVRP | Copper conductor XLPE insulated and PVC sheathed control cable | |
with copper tape longitudinal screen | ||
KYJVRP2 | Copper conductor XLPE insulated and PVC sheathed flexible control | |
cable with copper tape lapping screen |
KYJV22 | Copper conductor XLPE insulated and PVC sheathed control cable with steel tape armour | For flxed installation,laying indoors, in trenches and ducts,directement in ground where heavier mechanical force withstood |
KYJV32 | Copper conductor XLPE insulated and PVC sheathed control cable | For laying indoor, dans les tunnels, conduits, conduit and direct burial etc. Permanent place, able to bear greater mechanical force |
with steel wire armour | ||
KYJVP2-22 | Copper conductor XLPE insulated and PVC sheathed steel tape armored control cable with copper tape lapping screen | For fixed installation,laying indoors,in trenches and ducts,directly in ground where heavier mechanical force and interference resistance withstood. |
À propos du service après-vente de VERI Cable
D'abord, Engagement qualité du produit:
- Il existe des enregistrements de qualité et des données de test pour la fabrication et les tests de tous produits de câble.
- Pour le contrôle des performances des produits, nous invitons sincèrement les utilisateurs à inspecter l'ensemble du processus et les performances du produit en personne. Une fois que le produit est confirmé comme étant qualifié, il sera emballé et expédié.
Deuxième, l'engagement sur le prix du produit:
- Afin de garantir la haute fiabilité du produit, la sélection des matériaux du système est faite de produits nationaux ou de haute qualité.
- Dans les mêmes conditions de concurrence, notre entreprise vous fournira sincèrement à un prix abordable sans réduire les performances techniques du produit ni modifier les composants du produit.
- Engagement de délai de livraison:
Troisième, Délai de livraison du produit:
Dans la mesure du possible selon les besoins des utilisateurs, s'il y a des exigences particulières qui doivent être remplies à l'avance, notre société peut spécialement organiser la production et l'installation, et nous efforçons de répondre aux besoins des utilisateurs.
Quatrième, engagement service après-vente:
- Principe du service: rapide, décisif, précis, réfléchi et minutieux.
- Objectifs du service: la qualité du service pour gagner la satisfaction du client.
- Efficacité des services: Si l'équipement tombe en panne pendant la période de garantie ou en dehors de la période de garantie, après que le fournisseur ait été informé, le personnel de maintenance peut atteindre le site et commencer la maintenance dans les délais 24 heures.
- Principe de service: La période de garantie des produits de câble est de douze mois. Pendant la période de garantie, le fournisseur réparera et remplacera gratuitement les pièces endommagées pour des raisons de qualité. Si les pièces sont endommagées en dehors de la période de garantie, les accessoires fournis ne factureront que le coût des dommages à l'équipement causés par des facteurs humains de l'acheteur, et les accessoires réparés ou fournis par le fournisseur sont calculés au prix coûtant.