Câble moyenne tension
VERI Cable Manufacturers is a specialized supplier of medium voltage underground power cables. VERI Cable’s standard medium voltage underground transmission lines include single and three-core copper or aluminum conductor cables. It also includes polyvinyl chloride (PVC), polyéthylène réticulé (XLPE), polyéthylène (PE), ethylene propylene rubber (REP), et low-smoke, no-halogen (LSZH) jacketing. As well as steel wire armoring or aluminum wire armoring for added mechanical strength and to provide mechanical protection. VERI medium voltage power cables are available in voltages ranging from 3.6 kV to 35 kV. As one of the leading voltage cable suppliers in the country, VERI Cable has an extensive inventory of voltage power cables. Tel que high voltage cables, medium voltage cables, et câbles basse tension. They are all available for quick shipment.
Types of VERI Medium Voltage Cable
15/25/35kv MV AL Conductor XLPE Insulation NA2XY Cable
The medium voltage power cable can be used for laying indoors and outdoors. It can bear certain traction during installation. But not external mechanical forces. Laying single-core cables in magnetic ducts is not allowed. VERI medium voltage cable design based on the major national or international standards includes VDE, CEI, and ICEA. Or according to customers’ conception et normes, we can support the customized cable product.
Conducteur: Cu / Al / Al Alloy
Matériau isolant: PVC / XLPE
Nombre de cœurs: 1–5 Cores
Veste: PVC / PE / LSZH
Armour Type: STA / SWA
Attestation: ISO9001 / ISO14001 / OHSAS18001 / CCC
Model Number: VV, VV22, VV32, YJV, YJV22, YJV32
Taille: 2.5~630mm2
Taper | Nom | Usage |
VV | PVC insulated PVC sheathed power cable | Can be laid at indoor, tunnel, and tube. The cable cannot undertake mechanisms outside of force |
VLV | ||
VY | PVC insulated and PE sheathed power cable | Can be laid indoors, in tunnel tubes, and seriously polluted places. Cable cannot undertake mechanisms outside of force |
VLY | ||
VV22 | PVC insulated steel belt armored and PVC sheathed power cable | Can be laid indoors, in tunnel tubes, and mining wells. The cable cannot undertake mechanisms outside of force |
VLV22 | ||
VV23 | PVC insulated steel belt armored and PE sheathed power cable | Can be laid at indoor, tunnel tube mining wells, and seriously polluted places. The cable cannot undertake mechanisms outside of force |
VLV23 | ||
VV32 | PVC insulated fine steel wire armored PVC sheathed power cable | Can be laid at indoor, underground, and mining wells. Cable can undertake mechanism outside of force |
VLV32 | ||
VV33 | The PVC-insulated fine steel wire armored PE sheathed power cable | Can be laid indoors, or underground. The cable can undertake mechanisms outside of force |
VLV33 | ||
VV42 | PVC insulated thick steel wire armored PVC sheathed power cable | Can be laid indoors, underground, or mining well. The cable can undertake mechanisms outside the force |
VLV42 | ||
VV43 | The PVC-insulated fine steel wire armored PE sheathed power cable | Can be laid indoors, underground, in mining wells, and in places to are polluted. Cable can undertake mechanism outside force |
NORMES&LES RÉFÉRENCES: IEC60502-2, BS7870-4, BS7870-7, BS7870-8
APPLICATION: It is suitable for power distribution lines or fixed installations indoors/outdoors. It is enclosed in a conduit in the underground duct. Aussi, it is not subject to mechanical damage.
1.8/3kV 35kV MV CU/XLPE/PVC/SWA/PVC XLPE Cable
Medium voltage power cables are also the main transmission cables. And they carry electricity below the surface of the water. They are suitable for power transmission, distribution, and other essential electrical transfer lines. Now you can get a medium voltage cable price list from us.
DEMANDE
The type of MV power cable fully uses the characteristics of non-interference between optical signals and electric signals. For intricate lines, it can provide a strong foundation of protection and save resources—and medium voltage cables for distribution networks. VERI medium voltage cables are convenient to use. And they can be laid with no restriction of different elevations.
Part Number | Cross Section | Échouage | Approx Weight | Approx Overall Diameter | Gland Size | Single Cleat | Nom. Max.. DC-resist conductor 20° C | Current rating laid direct |
(mm²) | (mm) | KG/KM | (mm) | (mm) | (Ohm/km) | (Amp) | ||
11KVPVC3X16 | 3 x 16 | 7/1.70 | 3440 | 44.3 | 40 | 1.8 | 1.15 | 119 |
11KVPVC3X25 | 3 x 25 | 7/2.14 | 4060 | 48.5 | 50 | 2 | 0.727 | 152 |
11KVPVC3X35 | 3 x 35 | 7/2.52 | 4495 | 50.5 | 50 | R9 | 0.524 | 181 |
11KVPVC3X50 | 3 x 50 | 19/1.78 | 5115 | 53 | 63s | R9 | 0.387 | 213 |
11KVPVC3X70 | 3 x 70 | 19/2.14 | 6035 | 56.8 | 63s | R10 | 0.268 | 260 |
11KVPVC3X95 | 3 x 95 | 19/2.52 | 7180 | 61.3 | 63 | R10 | 0.193 | 309 |
11KVPVC3X120 | 3 x 120 | 37/2.03 | 8280 | 65.1 | 75s | R11 | 0.153 | 349 |
11KVPVC3X150 | 3 x 150 | 37/2.25 | 9325 | 66.8 | 75s | R11 | 0.124 | 390 |
11KVPVC3X185 | 3 x 185 | 37/2.52 | 10740 | 72.3 | 75 | R12 | 0.0991 | 436 |
11KVPVC3X240 | 3 x 240 | 61/2.52 | 13820 | 79.3 | 90 | R14 | 0.0754 | 499 |
11KVPVC3X300 | 3 x 300 | 61/2.85 | 16120 | 84.2 | 90 | R15 | 0.0754 | 553 |
11KVPVC3X400 | 3 x 400 | 61/3.20 | 19350 | 92.4 | R15 | 0.047 | 619 |
- Minimum installation temperature: 0°C ;
- Maximum installation temperature: +60°C;
- Installation type: Outdoor – Direct burial;
- Minimum operating temperature:-15°C Maximum operating temperature:90°C;
- Short-circuit max. conductor temperature: 250°C;
- Ignifuge: BS EN 60332
XLPE Insulated Single Core MV N2XSY Cable
N2XSY is a single-core copper conductor XLPE-insulated cable with PVC over sheath, which forms an essential part of Eland Cables’ international medium voltage cable portfolio. It is a cable suitable for indoor and outdoor static installation, directly in the ground or in cable ducts, as part of power distribution networks, transformer stations, switching blocks, et centrales électriques, including in the renewable energy sector. The N2XSY is self-extinguishing and flame retardant to VDE 0482-332-1-2 et CEI 60332-1.
N2XSY VOLTAGE RATING:
This range of medium voltage power cables manufactured in accordance to VDE 0276-620, HD 620 et VOTRE UN 60228 class 2 is available with the following voltage rating:
6/10 (12)kV – Test Voltage 21kV
12/20 (24)kV – Test Voltage 42kV
18/30 (36)kV – Test Voltage 63kV
Some of this cable’s properties, such as the flexibility of its conductor, facilitate the N2XSY’s installation, even on challenging routes and in difficult conditions. It can be manipulated and installed in ambient temperatures ranging between -5℃ and +70℃.
N2XSY XLPE PVC – 6/10 (12)KV CABLE | N2XSY XLPE PVC – 12/20 (24)KV CABLE | N2XSY XLPE PVC – 18/30 (36)KV CABLE | |
VOLTAGE | 6/10 (12)kV | 12/20 (24)kV | |
CONDUCTOR | Classe 2 Stranded Copper | ||
INNER SEMI-CONDUCTIVE LAYER | Semi-Conductive Material | ||
INSULATION | XLPE (Cross-Linked Polyethylene) | ||
OUTER SEMI-CONDUCTIVE LAYER | Semi-Conductive Material | ||
SCREEN | Copper Wires | ||
OUTER SHEATH | PVC (Chlorure de polyvinyle) |
Avantages:
Cross-linked polyethylene insulated power cable not only has excellent electrical properties, mechanical properties, heat aging properties, environmental stress resistance, and chemical corrosion resistance but also has the advantages of simple structure, facile à utiliser, not limited by laying drop, long-term working temperature (90 degrés), large transmission capacity, etc..
A Perfect Partnership with VERI
JKLYYJY 24KV 1*185 Outside Diameter (mm): 29.8
Total: 100km
240mm x 3 core Cu XLPE PVC SWA PVC (FR) 6.35/11kV to SABS 1339 Câble
Total: 16500m
Câbles VÉRI’ medium voltage power products and accessories have been well received by our friends around the world, and we continue to work hard on this path. You can rest assured that VERI products are of high quality and certified, never short of quality, and delivered on time.
Transportation with ZMS Professional Service
VERI Cable propose plusieurs façons de protéger vos câbles, avec un emballage d'expédition robuste et professionnel et une assurance tous risques. Avant l'expédition, notre câbles sont conditionnés en bobines de bois et en bobines de carton ondulé. Pendant le transport, pour protéger les extrémités des câbles de l'humidité, nous les scellons avec du ruban adhésif BOPP et non hygroscopique.
S'il y a des problèmes de qualité tels qu'un emballage endommagé et des dommages à la surface du produit sur place lors de la réception des marchandises, si les marchandises sont confirmées comme étant vraies, les marchandises ne correspondent pas à la commande, et les problèmes de qualité rencontrés par le client lors de l'installation, le processus de pose et d'utilisation est confirmé comme étant les problèmes de qualité du produit lui-même, Si la livraison n'est pas conforme aux exigences du contrat, s'il te plaît contactez notre entreprise directement.