CÁBLA IONSTRAIM

Instrumentation Cable

To date, VERI Cable has produced instrumentation cables for use in a variety of applications, including fully automated production, power equipment, tunnel lighting, or laying into cable trenches. The length of the cables sold reaches níos mó ná 50,000 méadar, and their resistance to moisture and corrosion is widely appreciated.

Instrumentation cables manufactured by VERI Cable are certified to GB, IEC, BS, ASTM, ISO900, ISO14000, ISO14001, ISO18000, BS, CE, IEC, NFC, ASTM and DIN.

Fiosrúchán Anois

Fiosrúchán Anois

CU/XLPE Insulated Instrument Cable---0.6/1KV

450/750v 0.5mm2 0.75mm2 1mm2 CU/XLPE insulated instrumentation cable

Construction
Seoltóir: Annealed or tinned copper
Pairing: Two or three insulated conductors uniformly twisted together with a lay not exceeding 100 mm
Binder Tape: PETP transparent tape
Caighdeán
IEC 60502, BS 5308, GB 9330

Shielding

Braid

Jacket/Insulation

PVC/XLPE/PE

Voltas Rátáilte

600V

Méid

0.5mm2-1000mm2 customizable

Cineál

Low Voltage/Medium Voltage/High Voltage

Certificate

ISO, CCC, CE, VDE

Cineál Seoltóra

flexible

Sheath

PVC Sheath

Dath Sheath

Black or blue

Buntáistí:
Fire prevention, anti-impact, anti-rat, anti-mosquito, anti-radiation
Low working temperature
Strong overload resistance
Long service life, high safety, explosion-proof, corrosion resistance
High mechanical strength

Typically used in industrial process manufacturing plants for communications, sonraí, and voice transmission of signals and services, and also for the interconnection of electrical equipment and instruments, usually in the oil industry.

Copper Tape Screened Twisted Pair Instrument Cable

Individual Screen Armored Instrument Cable application:
Instrumentation cable Individual and overall Screened Steel Wire Armored/ SWA Pairs are used in data processing and process control. Suitable for fixed installations in damp locations and open spaces. The electrostatic screen protects against outer interference fields.

1. Design: LSZH (Hailigine Íseal Deatach nialasach) Instrumentation cable consisting of bare copper conductors, black & white, twisted pairs or black, white & red twisted triples with a continuous number sequence.

2. Rátáil Voltais: Rated Voltage Max. 300V a.c; Nominal Voltage A.C/D. C 110/150V, Test Voltage In process spark test – 4500V and AC withstand

voltage test – 1500V, TECHNICAL DATA 0.5mm 1.5mm

3. Operating Temperature: Minimum continuous operating temperature -25°C,75°C, 90°C, Minimum short circuit temperature 160°C (for 5 sec)

Ábhar Seoltóra

Copper/copper aluminum tinned copper wire aluminum alloy

Ábhar Inslithe

PVC/XLPE

Shielding

Foil

Seaicéad

PVC

Dath

all kinds of color is available

Caighdeán

IEC BS ASTM DIN GB9330-1998

Sectional area

0.75 mm2 – 10 mm2

armored

steel tape steel wire

Sheath Istigh

LSZH (Hailigine Íseal Deatach nialasach) Sheath

Outer Sheath

LSZH (Hailigine Íseal Deatach nialasach) Sheath is flame retardant, conforms to IEC60332-3-22, halogen-free, conforms to IEC60754-1, low smoke emissions, conforms to IEC61034-1-2

Conductor sizes

0.5 mm² solid, 1.0 mm² solid, 0.5 mm² flexible, 0.75 mm² flexible or 1.5mm²stranded

Collective screen

24 µm aluminum / PETP tape over tinned copper drain wire, 0.5 mm²

Maximum Capacitance:
Conductor to Conductor 145pF/m 200pF/m, Conductor to Screen 240pF/m 300pF/m, Maximum Conductor Resistance @ 20 C 38.4Ω/km 13.8Ω/km,
Insulation Resistance @ 20 C 40MΩ/km 140MΩ/km, Cross Talk Attentuation Between Pairs @ 1kHz 300Ω 150Ω
Inductance @ 1kHz 1.00mH/km 0.95mH/km, L/R Ratio @ 1kHz 13.7µH/Ω 36.5µH/Ω
Bending Radius:
The following minimum bending radius should be observed to ensure operating reliability
unarmoured: 9 x cable outer diameter (during installation) 6 x cable outer diameter (after installation)
Armoured: 18 x cable outer diameter (during installation) 12 x cable outer diameter (after installation)

Underwater Instruments Flat Shaft Electrical Cable

This product can be used as an underwater communication cable. It can be either a single network cable structure a coaxial cable structure, a network cable plus multicore power cable, or a coaxial cable plus multicore control cable structure. The network cable is more than Category 5 or Category 6, and the video cable is commonly used as 75-3/75-5, srl. This product can also be used as an underwater telephone line. When using it, you can choose 2 pairs to use as video recording lines, and you can choose any pair to use as a telephone line or as a communication cable. It is simple to use and convenient to maintain.

Characteristics of Underwater Network Cable:
It is resistant to underwater pressure, seawater corrosion, underwater low temperature, ola, cold, creimeadh, UV, scríobadh, lasair-retardant, and bending. It applies to the rapid movement and installation of instruments and equipment in the underwater field.

Seoltóir

multi strand super fine stranded oxygen free copper wire

Ábhar Inslithe

high-densitywaterproof material

Shielding

tinned copper wire fabric

Seaicéad

seawater resistant polyurethane

Dath

core wires are distinguished by different colors

Network cable type

CAT5E/CAT6/CA6A

tensile strength

100/300/500KGcustomized

Rated voltage

300/300V

Collective screen

24 µm aluminium / PETP tape over tinned copper drain wire, 0.5 mm²

Water depth

100M/200m/500m, srl

Temperature range of underwater network cable:
Fixed installation – 40 ℃ to+85 ℃
Mobile installation: – 30 ℃ to+85 ℃

Bending radius of zero buoyancy steel wire mesh:
Fixed installation: 5 × Cable outer diameter (D)
Mobile installation: When the strokeis<10m, the bending radius is 7.5 × D When the stroke is ≥ 10m, the bending radius is 10 × D

Instrument Cable Installation and Wiring Tips

  1. —Under the eaves. Standard cables can be used only if the cable is not exposed to direct sunlight or extreme heat, and conduit is recommended. Do not use cables without UV protection in direct sunlight.
  2. —On the outer wall. Avoid direct sunlight on the wall and man-made damage. Heating cables are exposed to high temperatures in metal conduit or trunking, and many polymeric materials experience reduced service life at these temperatures.
  3. —In pipes (plastic or metal). If in pipes, pay attention to the damage to plastic pipes and the heat conduction of metal pipes. Once mechanical damage occurs, fiber optic cables are expensive to repair, requiring at least two terminations at each discontinuity point.
  4. —Suspended applications/overhead cables. Consider cable sag and stress. The cable is exposed to direct sunlight or not.
  5. —Directly laying in the underground cable trench, this environment is the smallest control range. The installation of the cable trench should be checked regularly for dryness or dampness. If the shield of the control cable needs to be grounded, the appropriate standards must be followed.

VERI Transportation with Professional Service

VERI Cable has multiple ways to protect your cables, le pacáistiú loingseoireachta láidir agus gairmiúil agus árachas cuimsitheach. Roimh loingsiú, tá ár gcáblaí pacáistithe i ríleanna adhmaid agus cornaí bosca roctha. Le linn iompair, chun foircinn an chábla a chosaint ó thaise, déanaimid iad a shéaladh le téip féinghreamaitheach BOPP agus neamh-hygroscópach.

Má tá fadhbanna cáilíochta cosúil le pacáistiú damáiste agus damáiste dromchla táirge ar an láthair nuair a fhaightear na hearraí, má dheimhnítear go bhfuil na hearraí fíor, ní hionann na hearraí agus an t-ordú, agus na fadhbanna cáilíochta a d'aimsigh an custaiméir le linn na suiteála, Deimhnítear gurb iad na fadhbanna cáilíochta a bhaineann leis an táirge féin an próiseas leagan agus úsáide, Mura bhfuil an seachadadh de réir riachtanais an chonartha, le do thoil déan teagmháil lenár gcuideachta go díreach.

    Ná bíodh drogall ort d’fhiosrúchán a thabhairt san fhoirm thíos.

    Ríomhphost(ag teastáil)*:

    Do ainm(ag teastáil):

    Do thír:

    TEIL*:

    Eolas*: