כבל צרור אווירי

Aerial Bundled Conductor

VERI ABC Cable is extensively used for combining single-core or multiple single-core cables. And their specifications are 0.6/1kv or 6.5/35kv. Then ABC cables are widely used to temporarily distribute street lighting and secondary pole service.

As a professional יצרן כבלים, our cable products are all of the best quality. Such as low voltage, סיבים אופטיים, airport lighting, ו solar cables. And they have been exported to many countries every year—for example, Australia, סְפָרַד, Kenya, Rwanda, and Bangladesh. So we will deliver each order strictly according to the delivery time. And we ensure the smooth progress of the customer’s projects.

VERI Aerial Bundle Cable Types

XLPE Insulation ABC Cable

Aluminum XLPE Aerial Bundled Cable 4x35mm

1. Voltage: 0.6/1KV.
2. מְנַצֵחַ: Pure annealed copper or aluminum.
3. בִּדוּד: XLPE/PE/PVC.
4. Cores: 1 ג, 2ג, 3ג, 4ג.
5. Nominal Cross-section: 10mm2 to 400mm2.
6. תֶקֶן: GB/T 14049-2008, חברת החשמל 60502.
7. מקסימום. טמפרטורת הפעלה: XLPE/PE: 90 מעלות צלזיוס, PVC: 70 מעלות צלזיוס.
8. סוּג: ABC Cable, JKTRYJ, JKLYJ,JKTRY, JKLY, JKLGYJ, JKLGY, JKLYJ/Q, JKLY/Q, JKLGYJ/Q, JKLGY/Q.
9. אֲרִיזָה: Wooden Drum or according to the customer requirement.
The cable can be of flame retardant, fire resistance, and other properties.

ABC – Aerial Bundled Cables, acc. BS (British Standard) 7870-5

number of cores x nominal cross-sectionmax. conductor-resistancemin. breaking load of conductor strandcurrent rating in the airouter diameterAL numbertotal weight
מ"מOhm/kmkNאca. מ"מק"ג/ק"מca. ק"ג/ק"מ
1x 16 RM1,9102,5728,05574
1x 25 RM1,2004,01079,072106
1x 35 RM0,8685,513210,5102138
1x 50 RM0,6418,016511,8145182
1x 70 RM0,44310,720513,0203252
1x 95 RM0,32013,724015,4276333
1x 120 RM0,25318,629017,0348408
1x 150 RM0,20623,233419,0435502
1x 185 RM0,16428,738921,0537611
1x 240 RM0,12537,246724,0696801
2x 16 RM1,9102,57215,693147
2x 25 RM1,2004,010718,0145208
2x 35 RM0,8685,513220,0203277
2x 50 RM0,6418,016523,5290361
2x 70 RM0,44310,720525,4408505
2x 95 RM0,32013,724030,3551666
2x 150 RM0,20623,233438,08701004
4x 16 RM1,9102,57218,8186286
4x 25 RM1,2004,010721,2290430
4x 35 RM0,8685,513224,1406553
4x 50 RM0,6418,016527,8580746
4x 70 RM0,44310,720531,88121.009
4x 95 RM0,32013,724037,81.1021.332
4x 120 RM0,25318,629054,41.3921.632
4x 50 + 1x 25 RM0,641/1,2008,0/4,0165/10731,9653814
4x 50 + 1x 35 RM0,641/0,8688,5/5,5165/13231,9682845
4x 70 + 1x 25 RM0,443/1,20010,7/4,0205/10736,08851.105
4x 70 + 2x 25 RM0,443/1,20010,7/4,0205/10740,09561.217
4x 95 + 1x 25 RM0,320/1,20013,7/4,0240/10741,81.1751.438
4x 95 + 2x 25 RM0,320/1,20013,7/4,0240/10742,01.2471.544
4×120 + 1x 25 RM0,253/1,20018,6/4,0290/107591.4642.05

בַּקָשָׁה

Used to supply power, usually from a pole-mounted transformer, to the user’s service head where connection to the service entrance. To be used at 600V or less phase to phase and at conductor temperatures not to exceed 75°C for polyethylene insulated or 90°C for cross-linked. Not suitable for direct burial.

תקנים&הפניות: חברת החשמל 60502 / AS / NZS 3599-1 standards

שאל עכשיו
Insulation-ABC-twist-cable

Low Voltage Insulated Aerial Bundled ABC Cable

Low Voltage 3×95+1×70+1×16 3×120+1×70+1×16 3×150+1×95+1×16 3×185+1×120+1×16 Aerial Bundled Conductor ABC Cables details:

  • תֶקֶן: NFC 33-209.
  • Phase/Lightning conductor: Stranded All Aluminum 1350; AAC.
  • Phase conductor Insulation: XLPE.
  • Neutral conductor: All aluminum alloy.
  • Neutral/Lightning conductor insultation: XLPE.
  • The Rated Voltage: 0.6/1KV,מתח בדיקה : 4 kV AC

Product Specification

Nominal Cross Section
Minimum Breaking Load
Current Rating in Air
קוטר כללי נומינלי
Total Weight
Outer Diameter
מ"מ2
Kn
א
מ"מ
ק"ג/ק"מ
מ"מ
2*16RM
1.190
2.5
72
147
15.6
2*25RM
1.200
4.0
107
208
18
2*35RM
0.868
5.5
132
277
20
2*50RM
0.641
8.0
165
361
23.5
4*16RM
1.190
2.5
72
286
18.8
4*25RM
1.200
4.0
107
430
21.2
4*35RM
0.868
5.5
132
553
24.1
4*50RM
0.641
8.0
165
746
27.8
4*70RM
0.443
10.7
205
1.009
31.8
4*95RM
0.320
13.7
240
1.332
37.8
4*120RM
0.253
18.6
290
1.632
54.4
4*35+1*35RM
0.868/0.868
5.5/5.5
132/132
694
30
4*50+1*25RM
0.641/1.200
8.0/4.0
165/107
814
31.9
4*50+1*35RM
0.641/0.868
8.5/5.5
165/132
845
31.9
4*70+1*25RM
0.443/1.200
10.7/4.0
205/107
1.105
36
4*70+2*35RM
0.443/1.200
10.7/4.0
205/107
1.217
40
4*70+1*25RM
0.443/0.868
10.7/5.5
205/132
1.15
36.2
4*70+2*25RM
0.443/0.868
10.7/5.5
205/132
1.289
40.1
4*95+1*25RM
0.320/1.200
13.7/4.0
240/107
1.438
41.8
4*95+1*35RM
0.320/0.868
13.7/5.5
240/132
1.467
41.8
4*95+2*25RM
0.320/1.200
13.7/4.0
240/107
1.544
42
בַּקָשָׁה
Low Voltage Aerial Bundled Cables(ABC) are intended for use either as a service drop cable between a power pole and the service entrance or as a secondary distribution cable between poles. The use of this service drop or secondary distribution cables is limited to circuits, not exceeding 600 volts phase-to-phase or 480 volts phase-to-ground, to a normal temperature rating of the service conductor temperature of 90 מעלות צלזיוס.
תקנים&הפניות: IEC60502/ NF C33-209/GB 12527-90 ASTM
שאל עכשיו
Duplex-Service-Drop-Wire

Duplex / Triplex Service Drop Wire Aluminum Conductor

Duplex Service Drop Wire, its main composition is 1350-H19 aluminum with phase conductors concentrically twisted and PVC or XLPE for insulation. The neutral core is made of concentrically twisted AAC, ACSR, or 6201 aluminum alloy. Mainly used for 120V overhead service applications. Such as street lighting, outdoor lighting, and building temporary services. The voltage between the phases is 600V and below. The conductor temperature of PVC insulated conductors does not exceed 75 מעלות צלזיוס, and the conductor temperature of XLPE insulated conductors does not exceed 90 מעלות צלזיוס.

DUPLEX SERVICE DROP CABLE phase conductors are concentrically stranded according to ASTM B 231. Covered with weather-resistant black polyethylene compound. Neutral conductors are concentrically stranded ACSR according to ASTM B 232.

Cable Parameter Specifications

Conductors
סוּג

bare neutral messenger

Phase
מְנַצֵחַ

AAC

ACSR

Duplex service drop
ABC

Pekingese,Collie,

Dachshund, Spaniel,

Doberman, Malemute

Setter,Shepherd,Eskimo,
Terrier,Chow,Bull

AAC

Triplex service drop
ABC

Haiotis,Patella,Fusus,

Oyster,Clam,Murex,

Purpura,Nassa,
Melita,Portunus,

Nannynose

Paludina,Voluta,Whelk,

Periwinkle,
Conch,Neritina,

Cenia,Runcina,

Triton,
Cherrystone,Mursia,Razor,

Zuzara,
Limpet,Scallop,Strombus,

Cockle,
Janthina,Ranella,

Aega,Cavolinia,Clio,

Sanddollar,Cuttlefish,

Cerapus, Cowry

Quadruplex service drop
ABC

Cllydesdate,Pinto,

Mustang,
Criollo,Percheron,Hanoverian,
Olderburg,Lippizaner

Morochuca,Chola,Morgan,Hackney,
Palomino,Costena,Grullo,Appaloosa,
Bronco

Code

word

AWG or kcmil

Bare Neutral Messenger

Phase Conductor

Weight

ק"ג/ק"מ

ACSR

Rated Strength

lbs.

AAC

Insul.

Thick.

מ"מ

לֹא.

Dia.

מ"מ

לֹא.

Dia.

מ"מ

לֹא.

Dia.

מ"מ

Shepherd

1*6AWG+1*6AWG

1

1.68

6

1.68

1190

7

1.56

1.14

113

Applications
Primarily used for overhead service applications such as street lighting, outdoor lighting, and temporary construction service. To be used at voltage of 600V phase-to-phase or less and at conductor temperatures not to exceed 75℃ for polyethylene insulated conductors or 90℃ for crosslinked polyethylene(XLPE) insulated conductors.

Service drop cable meets or exceeds the following specifications:

  • ASTM B-230 Aluminum Wire,1350-H19 for Electrical Purposes.
  • ASTM B-231 Aluminum Conductors, Concentric-Lay-Stranded.
  • ASTM B-232 Aluminum Conductor, Concentric-Lay-Stranded, Coated Steel Reinforced(ACSR)
  • ASTM B-399 Concentric-Lay-Stranded 6201-T81 Conductors
  • ASTM B-901 Compressed Round Stranded Aluminum Conductors Using Single Input Wire.
שאל עכשיו

הובלה עם שירות מקצועי

ניסיון לייצא

כיצרן כבלים מקצועי, מוצרי הכבלים שלנו יוצאו למדינות רבות בעבר 30 שנים, כולל ארה"ב, קנדה, סְפָרַד, בְּרִיטַנִיָה, גֶרמָנִיָה, צָרְפַת, רוּסִיָה, יָוָן, ערב הסעודית, וכו. במדינות אלו, מוצרי הכבלים שלנו פופולריים מאוד בקרב לקוחות. וכל שנה, בגלל האיכות והשירות הטובים שלנו, נקבל הרבה משוב טוב מהלקוחות שלנו.

שירות כבלים מותאם אישית

מגוון השירותים המותאמים שלנו כולל עיצוב, גוֹדֶל, וצבע פני השטח. צבעים פופולריים רבים זמינים גם לבחירתך. אנו מתמחים גם בכיסוי יתר, לְדוּגמָה, אנחנו יכולים לעשות פוליאתילן בהתאמה אישית (פ) ופוליאוריתן (PUR) לפי הדרישות שלך. אנו יכולים לספק פתרונות המבוססים על הרעיונות שלך. אנא צור איתנו קשר כדי לתת לנו את הרעיון שלך.

תקני בדיקת איכות מחמירים

VERI Cable offers a wide variety of power cables based on trends and personal preferences. ואנחנו מספקים כל מיני כבלי חשמל, יותר מ 100 סִדרָה. אָז, כדי להבטיח את איכות הכבלים, אנחנו מתעקשים לבדוק את המוצרים שלנו מדי פעם.

    אנא אל תהסס לתת את שאלתך בטופס למטה.

    אֶלֶקטרוֹנִי(דָרוּשׁ)*:

    השם שלך(דָרוּשׁ):

    המדינה שלך:

    טל*:

    מֵידָע*: