Instrumentation Cable
To date, VERI Cable has produced instrumentation cables for use in a variety of applications, including fully automated production, power equipment, tunnel lighting, or laying into cable trenches. The length of the cables sold reaches lebih dari 50,000 meter, and their resistance to moisture and corrosion is widely appreciated.
Instrumentation cables manufactured by VERI Cable are certified to GB, IEC, BS, ASTM, ISO900, ISO14000, ISO14001, ISO18000, BS, CE, IEC, NFC, ASTM and DIN.
CU/XLPE Insulated Instrument Cable---0.6/1KV
450/750v 0.5mm2 0.75mm2 1mm2 CU/XLPE insulated instrumentation cable
Konstruksi
Konduktor: Annealed or tinned copper
Pairing: Two or three insulated conductors uniformly twisted together with a lay not exceeding 100 mm
Binder Tape: PETP transparent tape
Standar
IEC 60502, BS 5308, GB 9330
Shielding | Braid |
Jacket/Insulation | PVC/XLPE/PE |
Rated Voltage | 600V |
Size | 0.5mm2-1000mm2 customizable |
Jenis | Low Voltage/Medium Voltage/High Voltage |
Certificate | ISO, CCC, CE, VDE |
Conductor Type | flexible |
Sheath | PVC Sheath |
Sheath Color | Black or blue |
Advantages:
Fire prevention, anti-impact, anti-rat, anti-mosquito, anti-radiation
Low working temperature
Strong overload resistance
Long service life, high safety, explosion-proof, corrosion resistance
High mechanical strength
Typically used in industrial process manufacturing plants for communications, data, and voice transmission of signals and services, and also for the interconnection of electrical equipment and instruments, usually in the oil industry.
Copper Tape Screened Twisted Pair Instrument Cable
1. Design: LSZH (Low Smoke Zero Halogen) Instrumentation cable consisting of bare copper conductors, black & white, twisted pairs or black, white & red twisted triples with a continuous number sequence.
voltage test – 1500V, TECHNICAL DATA 0.5mm 1.5mm
Bahan Konduktor | Copper/copper aluminum tinned copper wire aluminum alloy |
Bahan Isolasi | PVC/XLPE |
Shielding | Foil |
Jaket | PVC |
Warna | all kinds of color is available |
Standar | IEC BS ASTM DIN GB9330-1998 |
Sectional area | 0.75 mm2 – 10 mm2 |
armored | steel tape steel wire |
Inner Sheath | LSZH (Low Smoke Zero Halogen) Sheath |
Outer Sheath | LSZH (Low Smoke Zero Halogen) Sheath is flame retardant, conforms to IEC60332-3-22, halogen-free, conforms to IEC60754-1, low smoke emissions, conforms to IEC61034-1-2 |
Conductor sizes | 0.5 mm² solid, 1.0 mm² solid, 0.5 mm² flexible, 0.75 mm² flexible or 1.5mm²stranded |
Collective screen | 24 µm aluminum / PETP tape over tinned copper drain wire, 0.5 mm² |
Underwater Instruments Flat Shaft Electrical Cable
This product can be used as an underwater communication cable. It can be either a single network cable structure a coaxial cable structure, a network cable plus multicore power cable, or a coaxial cable plus multicore control cable structure. The network cable is more than Category 5 or Category 6, and the video cable is commonly used as 75-3/75-5, dll.. This product can also be used as an underwater telephone line. When using it, you can choose 2 pairs to use as video recording lines, and you can choose any pair to use as a telephone line or as a communication cable. It is simple to use and convenient to maintain.
Konduktor | multi strand super fine stranded oxygen free copper wire |
Bahan Isolasi | high-densitywaterproof material |
Shielding | tinned copper wire fabric |
Jaket | seawater resistant polyurethane |
Warna | core wires are distinguished by different colors |
Network cable type | CAT5E/CAT6/CA6A |
kekuatan tarik | 100/300/500KGcustomized |
Tegangan terukur | 300/300V |
Collective screen | 24 µm aluminium / PETP tape over tinned copper drain wire, 0.5 mm² |
Water depth | 100M/200m/500m, dll. |
Bending radius of zero buoyancy steel wire mesh:
Instalasi tetap: 5 × Cable outer diameter (D)
Instalasi seluler: When the strokeis<10m, the bending radius is 7.5 × D When the stroke is ≥ 10m, the bending radius is 10 × D
Instrument Cable Installation and Wiring Tips
- —Under the eaves. Standard cables can be used only if the cable is not exposed to direct sunlight or extreme heat, and conduit is recommended. Do not use cables without UV protection in direct sunlight.
- —On the outer wall. Avoid direct sunlight on the wall and man-made damage. Heating cables are exposed to high temperatures in metal conduit or trunking, and many polymeric materials experience reduced service life at these temperatures.
- —In pipes (plastic or metal). If in pipes, pay attention to the damage to plastic pipes and the heat conduction of metal pipes. Once mechanical damage occurs, fiber optic cables are expensive to repair, requiring at least two terminations at each discontinuity point.
- —Suspended applications/overhead cables. Consider cable sag and stress. The cable is exposed to direct sunlight or not.
- —Directly laying in the underground cable trench, this environment is the smallest control range. The installation of the cable trench should be checked regularly for dryness or dampness. If the shield of the control cable needs to be grounded, the appropriate standards must be followed.
VERI Transportation with Professional Service
Kabel VERI memiliki berbagai cara untuk melindungi kabel Anda, dengan kemasan pengiriman yang kokoh dan profesional serta asuransi yang komprehensif. Sebelum pengiriman, kabel kami dikemas dalam gulungan kayu dan gulungan kotak bergelombang. Selama transportasi, untuk melindungi ujung kabel dari kelembapan, kami menyegelnya dengan pita perekat BOPP dan tidak higroskopis.
Jika terdapat masalah kualitas seperti kerusakan kemasan dan kerusakan permukaan produk di tempat saat barang diterima, jika barang dipastikan kebenarannya, barang tidak sesuai pesanan, dan masalah kualitas yang ditemukan oleh pelanggan selama instalasi, proses peletakan dan penggunaan dipastikan menjadi masalah kualitas produk itu sendiri, Jika pengiriman tidak sesuai dengan persyaratan kontrak, Tolong hubungi perusahaan kami secara langsung.