Undersea Power Cable
Kabel VERI, specializing in submarine power cables, is suitable for telecommunications or transmission between countries or regions. We manufacture high-quality submarine cables with different voltages. In addition to our standard marine cable range, we support designing some special cables for specific project applications. VERI submarine power cables are manufactured as VDE, IEC, and ICEA or according to customers’ desain dan standar. For more information about our solutions for cable products, jangan ragu untuk menghubungi kami.
Submarine Cable Type and Application
XLPE Insulated AC Medium Voltage Submarine Power Cable
These submarine power cables are used for power transmission to offshore islands, platform minyak, or cross-rivers and lakes. The laying of submarine cables does not require digging tunnels or supporting them with brackets, and low investment or fast construction.
- Konduktor: Konduktor tembaga, melingkar terdampar dipadatkan, air tersumbat
- Pemutaran Konduktor: Senyawa semi konduktif yang diekstrusi
- Isolasi: XLPE
- Pemeriksaan Isolasi: Senyawa semi konduktif yang diekstrusi
- Waterproof layer: semi-conductive waterproof tape
- Layar: Copper tapes
- Pemisah: Plastic foil
- Core Sheath: PE
- Pengisi: Pengisi polipropilena
- Pemisah: Pita pengikat
- Lapisan Tempat Tidur: Senar polipropilen
- Armor: Kabel baja galvanis
- Porsi: Hessian tapes, senyawa bitumen, string polipropilen
Specification Size and Technical Data:
Core number | Nominal Section(mm²) | D.C.Resistance in 20 HaiC(Ω/km) | O.D.(mm) | Reference Weight(Kg/km) | ||
CU | AL | Cu | Al | |||
1 inti | 1.5 | 24 | – | 6.1 | 49.2 | 46.6 |
2.5 | 34 | 25 | 6.5 | 61.6 | 61.5 | |
4 | 44 | 33 | 7.4 | 85.4 | 74.3 | |
6 | 57 | 44 | 8.0 | 109 | 90.1 | |
10 | 76 | 58 | 9.6 | 151 | 116 | |
16 | 103 | 78 | 10.2 | 223 | 173 | |
25 | 129 | 108 | 12.0 | 331 | 212 | |
35 | 172 | 131 | 13.1 | 432 | 272 | |
70 | 268 | 207 | 16.0 | 780 | 472 | |
150 | 435 | 335 | 22.1 | 1609 | 821 | |
185 | 493 | 380 | 24.2 | 1966 | 1028 | |
240 | 585 | 451 | 26.9 | 2513 | 1265 | |
2 inti | 1.5 | 802 | 624 | 33.5 | 4108 |
|
2.5 | 20 |
| 10.2 | 116 | 117 | |
4 | 27 | 21 | 11.0 | 148 | 159 | |
6 | 36 | 27 | 12.8 | 207 | 194 | |
10 | 46 | 35 | 13.8 | 262 | 228 | |
16 | 62 | 48 | 15.4 | 351 | 301 | |
25 | 83 | 63 | 18.5 | 532 | 456 | |
50 | 131 | 101 | 24.3 | 1017 | 573 | |
70 | 164 | 127 | 22.4 | 1201 | 735 | |
95 | 208 | 160 | 25.2 | 1615 | 956 |
STANDAR&REFERENSI: IEC 60228, IEC 60502, IEC 60840, IEC 62067
Using Feature:
1. The long-time working temperature of the cable should not be higher than 70℃.
2. When the core is in short-circuit (max 5s) the temperature should not exceed 160℃.
A. For a single no-armored cable, it is not less than 20 times of outer diameter
b. For single-core armored cable, it is not less than 15 times of outer diameter
c. For multicore no-armored cable, it is not less than 15 times of outer diameter
D. For multicore armored cable, it is not less than 12 times of outer diameter
APPLICATION
The core of the submarine power cable is covered with a PE outer sheath. After the single steel armor, the cable is finally completed with an outer sheath. So it is mainly for all marine environmental conditions, such as muddy, dry, wet, or oily conditions meeting the requirements. The range of voltage is 6/10(12)persegi panjang,12/20(24)persegi panjang, 18/30(36)persegi panjang, dan sebagainya.
XLPE Insulated DC High-Voltage Submarine Cable
A high-voltage submarine cable is used for high-voltage power transmission. Most of the submarine power cables are on the seabed at a certain depth, and they are not damaging the natural environment, such as wind and waves. Human production activities have interfered with them. Karena itu, the cables are safe and stable, with strong anti-interference ability and good confidentiality.
- Konduktor: Konduktor tembaga, air tersumbat
- Pemutaran Konduktor: Senyawa semi konduktif yang diekstrusi
- Isolasi: XLPE
- Pemeriksaan Isolasi: Senyawa semi konduktif yang diekstrusi.
- Pemisah: Swelling tape
- Core Sheath1: Lead Sheath
- Core Sheath2: Selubung PE
- Bedding: Bedding layer
- Baju zirah: Galvanized steel wires filled with bitumen compound
- Porsi: Polypropylene yarn
STANDAR&REFERENSI:IEC 60228, IEC 60502, IEC 60840, IEC 62067
APPLICATION
As a high-voltage power transmission cable, it is major for carrying electric power below the surface of the water. The range of voltage is 127/220(245)persegi panjang, 160/275(300)persegi panjang, 200/345(362)persegi panjang, 230/400(420)persegi panjang, dan sebagainya.
Standar dan Penerapan
STANDAR: IEC 60502, IEC 62067
APLIKASI: This applies to a solidly earthed system with a power frequency of 50-60Hz and rated voltage from 1kV to 500kV. Mainly used for high-power electric power transmission between mainland and island, island and island, or mainland and platform; control signal transmission of smart grid and communication signal transmission.
Layanan Profesional Kami
Sertifikasi Mutu
Produk yang diproduksi oleh VERI Cables memenuhi standar internasional seperti GB, IEC, BS, NFC, ASTM, DARI, dll.. Lebih-lebih lagi, tim teknis kami dapat menyediakan layanan kustomisasi kabel untuk kebutuhan Anda.
Pelacakan Pelanggan
VERI menyediakan layanan konsultasi kabel profesional gratis, layanan solusi proyek terpadu, dan solusi pengiriman produk yang cepat.
Transportasi Profesional
Kabel VERI’ Tujuan awalnya adalah untuk memastikan pengiriman produk yang cepat dan aman sekaligus memberikan solusi pengemasan dan transportasi terbaik untuk mengurangi pelanggan’ biaya transportasi sangat besar.
Kemasan Kabel
Kemasan kabel VERI disediakan dalam gulungan kayu, kotak bergelombang, dan kumparan. Ujung-ujungnya disegel dengan pita perekat BOPP dan tutup penyegel non-higroskopis untuk melindungi ujung kabel dari kelembapan. Kami dapat mencetak logo yang dibutuhkan di bagian luar drum dengan bahan tahan air sesuai kebutuhan pelanggan.