High Voltage Cables

Cavo ad alta tensione XLPE

High Voltage Cables can be divided into aluminum-core high-voltage cables and copper-core cables according to different materials. Voltage Level Range: 6/64 kV, 48/66 kV, 66/120 kV, 127/220 kV and other ultra-high voltage. Due to the complex environmental conditions and special requirements in certain areas, l'uso di cavi con anima in rame è più affidabile in termini di qualità e sicurezza. According to our production experience, the selection of technical specifications and cross-sectional area of high-voltage cables should be made with reference to the surrounding environment, the corresponding laying method and the performance of electrical equipment. Benvenuto a get a free quotation.

Richiedi informazioni adesso

Tipi di cavi VERI ad alta tensione

Richiedi informazioni adesso

Cavo in rame ad alto coltage YJV22 10kv 35kv

YJV22 high voltage cables are used for power transmission and distribution high tension cable systems with rated voltages of 0.6/1kv, 1.8/3kv, 3.6/6kv, 6/10kv, 8.7/10kv, 8.7/15kv, 12/20kv, 21/35kv, 26/35kv.

1. Isolamento in XLPE, Cavi di alimentazione con guaina in PVC (YJV, YJLV) sono adatti per interni, tunnel, tubi, e sepolto nel terreno (non soggetto a forze meccaniche)
2. Isolamento in XLPE, cavi di alimentazione con guaina in PVC armato con nastro di acciaio (YJV22, YJLV22) sono adatti per interni, tunnel, penetrazione del tubo, e sepolto nel terreno
3. Isolamento in XLPE, cavi elettrici sotto guaina in PVC armato con filo di acciaio (YJV32, 42, YJLV32, 42) sono adatti per alberi, acqua, luoghi con discesa, e può resistere alle forze esterne.

The Minimum Bend Radius of the Cable

Articolo
Tre core
Senza armatura
Corazzato
Raggio minimo di curvatura del cavo in fase di installazione.
15D
12D
Il raggio di curvatura minimo del cavo vicino alla scatola di giunzione e al terminale
12D
10D
Nota: D è il diametro esterno del cavo

HV Cable Size Specification

Area della sezione trasversale(mm²)
Spessore isolante(mm)
Spessore dello scudo metallico(mm)
Spessore della giacca(mm)
DA(mm)
Peso(kg/km)
3×25
4.5
30×0.10
2.4
44.8
2251.6
3×35
4.5
40×0.10
2.5
47.2
2655.9
3×50
4.5
40×0.10
2.6
50.4
3217.3
3×70
4.5
40×0.10
2.7
54.0
3957.2
3×95
4.5
40×0.10
2.8
57.7
4884.7
3×120
4.5
40×0.10
2.9
60.9
5754.2
3×150
4.5
40×0.10
3.0
64.5
6788.0
3×185
4.5
40×0.10
3.1
68.2
7961.6
3×240
4.5
40×0.10
3.3
73.5
9801.3
3×300
4.5
40×0.10
3.4
78.3
11725.3
3×400
4.5
40×0.10
3.7
85.8
14799.2

Caratteristiche della struttura del prodotto:

1. Has Good High-Temperature Resistance: L'isolamento XLPE utilizza metodi chimici o fisici per modificare la struttura delle molecole di polietilene in una struttura di rete tridimensionale. La struttura della rete tridimensionale ha una buona resistenza al calore e può essere utilizzata in lavori a lungo termine ad alta temperatura 90 gradi Celsius, la durata della vita può essere lunga quanto 40 anni.
2. Good Insulation Performance: il polietilene non solo mantiene le prestazioni di isolamento del polietilene reticolato ma presenta anche un ulteriore miglioramento nella resistenza di isolamento.
3. High Mechanical Properties: durezza, rigidità, resistenza all'usura, e la resistenza agli urti sono state migliorate
4. Chemical Resistance: Lo stesso XLPE ha una forte resistenza agli acidi e agli alcali e agli oli
5. Environmental Protection: Poiché i prodotti della combustione del polietilene reticolato sono acqua e anidride carbonica, l'inquinamento ambientale è basso, e soddisfa i requisiti di sicurezza antincendio.
6. La temperatura nominale massima del conduttore del cavo è 90°C, e la temperatura massima durante il cortocircuito (la durata più lunga non supera i 5 secondi) non supera i 250°C.

Richiedi informazioni adesso

High Voltage Aluminum Overhead Lines

Conduttore in alluminio, cavo aereo rinforzato in acciaio, viene utilizzato principalmente nelle linee di trasmissione di potenza ad alta tensione. I suoi vantaggi includono un'elevata resistenza meccanica, buona conduttività elettrica, resistenza alla corrosione, volume dell'unità luminosa, facile erezione, resistenza alle alte temperature, struttura semplice, installazione conveniente, buona manutenzione, e grande capacità di trasmissione. Il cavo d'acciaio ad alta tensione di ACSR è costituito da un'anima in acciaio solida o intrecciata circondata da trefoli di alluminio.

  • Conduttore: Alluminio
  • Conduttore dell'illuminazione stradale: Conduttore in alluminio tondo o compatto
  • Isolamento: LDPE/HDPE/XLPE/PVC

NORME: GB/T12527/IEC60502/NFC 33-209/BS 7870/ANSI/ICEA S-76-474 AS/NZS 35601

Conduttore HV ACSR secondo GOST 839-80

SezioneParte in alluminioParte in acciaiominimo. Forza di rottura
Numero di filiNominativo. diametro del filoNumero di filiNominativo. diametro del filo
116/2.761.85 mm.11.85 mm.6,220 N.
225/4.262.30 mm.12.30 mm.9,296 N.
335/6.262.80 mm.12.80 mm.13,524 N.
450/8.063.20 mm.13.20 mm.17,112 N.
570/1163.80 mm.13.80 mm.24,130 N.
670/72182,20 mm.192.20 mm.96,862 N.
795/1664.50 mm.14.50 mm.33,369 N.
8120/19262.40 mm.71.85 mm.41,521 N.
9120/27302.20 mm.72.20 mm.49,465 N.
10150/19242.80 mm.71.85 mm.46,307 N.
11150/24262.70 mm.72.10 mm.52,279 N.
12150/34302.50 mm.72.50 mm.62,643 N.
13185/24243.15 mm.72.10 mm.58,075 N.
14185/29262.98 mm.72.30 mm.62,055 N.
15185/43302.80 mm.72.80 mm.77,767 N.
16205/27.0243.30 mm.72.20 mm.63,740 N.
17240/32243.60 mm.72.40 mm.75,050 N.
18240/39263.40 mm.72.65 mm.80,895 N.
19240/56303.20 mm.73.20 mm.98,253 N.
20300/39244.00 mm.72.65 mm.90,574 N.
21300/48263.80 mm.72.95 mm.100,623 N.
22300/204542.65 mm.372.65 mm.284,579 N.
23330/43.0542.80 mm.72.80 mm.103,784 N.
24400/18423.40 mm.71.85 mm.85,600 N.
25400/51543.05 mm.73.05 mm.120,481 N.
26400/64264.34 mm.73.40 mm.129,183 N.
27400/93304.15 mm.192.50 mm.173,715 N.
28500/27762.84 mm.72.20 mm.112,188 N.
29500/64543.40 mm.73.40 mm.148,257 N.
30600/72543.70 mm.192.20 mm.183,835 N.

APPLICAZIONE

Il tipo di questi cavi viene utilizzato nelle linee di distribuzione elettrica che attraversano fiumi e valli dove esistono creature geografiche speciali. Il conduttore dell'ACSR rappresenta il componente più importante di un linea elettrica aerea perché devono garantire una trasmissione economica e affidabile e contribuiscono notevolmente ai costi totali della linea.

Richiedi informazioni adesso

HDPE HV Cable 35KV to 110KV

HDPE high voltage cables are typically used in high voltage power transmission and distribution systems and are suitable for installation in ducts, trenches or direct burial underground or in buildings. These cables are also well suited for connecting wind farms and other renewable energy sources to existing grid systems.

Conduttore: Multi-strand round or segmented compacted copper or aluminum
Insulation shield: Non-metallicsemiconductor layer
Nastro: Semi-conductive resistive water tape
Guaina: Lead
Guaina: HDPE sheath (custom LSZH available)

NORME: CEI 60840

HDPE HV Technical Specification

Misurare

Conductor Diameter

Conductor Screen Thickness

Isolamento

Thickness

Nominal Core Diameter

Copper Wire Shield Area

HDPE Sheath Thickness

Approximate Overall Diameter

mm²

mm

mm

mm

mm

mm²

mm

mm

150

14.4

1.2

18

56.2

95

4

70.6

185

15.6

1.2

18

57.4

95

4

71.8

240

18.3

1.2

18

60.1

95

4

74.5

300

20.6

1.2

18

62.4

95

4

76.8

400

22.9

1.2

18

64.7

95

4

79.1

500

26.4

1.2

18

68.2

95

4.5

83.6

630

29.8

1.2

18

71.6

95

4.5

87

800

36

1.2

18

77.8

95

4.5

93.2

1000

38.2

1.5

18

81.2

95

4.5

97.6

1200

42.8

1.5

18

85.8

95

4.5

102.2

1400

46.4

1.5

18

89.4

95

4.5

105.8

1600

48.9

1.5

18

91.9

95

4.5

108.3

Product Advantages:

VERI Cables can ensure that the HDPE high voltage cables we produce meet national or international technical specifications. We can also provide accurate cable laying solutions for high voltage power projects based on the experience of our technical team, and all products can be supplied with formal test certificates.

Domande frequenti

What is the maximum voltage cable that can be supplied?

VERI cables can be supplied in different voltage ranges for high voltage lines, generally between 35kv and 220kv, for ultra high voltage cables we can supply cables ranging from 220kv to 500kv. As the voltage values increase, we opt for XLPE or oil-paper insulation technology to ensure the safe operation of UHV lines.

Qual è la quantità minima dell'ordine?

Tipicamente, la quantità minima d'ordine per tutti i cavi supportati da VERI Cables è 500 metri, a causa del peso di alcuni cavi, anche in piccole quantità, può essere molto elevato e può comportare disturbi nei costi di trasporto. Ti consigliamo quindi di scegliere di acquistare localmente per ordini di cavi inferiori a 500 metri. Puoi comunque inviarci la tua richiesta di cavi ad alta tensione.

Come comunico con te?

On VERI Cable's website, puoi contattarci tramite la casella di richiesta, e-mail (sales@vericable.com), Whatsapp (+86 17303836349). Supportiamo anche le videoconferenze con i nostri clienti e li invitiamo a farci visita.

Posa cavi VERI Alta Tensione

XLPE high voltage cable laying

Ispezione prima della posa dei cavi: se il modello e le specifiche soddisfano i requisiti, l'isolamento dovrebbe essere buono, l'aspetto dovrebbe essere completo, e non dovrebbero esserci tracce di trauma.

È necessario riservare una lunghezza di riserva vicino al terminale del cavo, e una lunghezza di riserva dovrebbe essere riservata al cavo direttamente interrato nella posa a forma di onda. La distanza tra ciascun fulcro del cavo dovrà essere quella specificata nel progetto. Quando non esistono norme di progettazione, non dovrebbe essere maggiore di gomma cavi. Questi cavi di plastica sono orizzontali 1M, verticale 2M, e cavi sospesi su cavi d'acciaio che sono orizzontali 0,75 M. Il raggio di curvatura del cavo non deve essere inferiore a 10 volte il diametro esterno del cavo (cavo di alimentazione multipolare armato o non armato con isolamento plastico).

Durante la posa dei cavi, i cavi devono uscire dall'estremità superiore della bobina, ed evitare attriti e trascinamenti dei fili sulla staffa e sul terreno. I cavi non devono incrociarsi durante la posa, dovrebbero essere disposti in modo ordinato, e fisso, e la segnaletica dovrebbe essere installata. Dovrebbero esserci dei picchetti fissi agli angoli dei cavi direttamente interrati. Quando i cavi entrano nelle fosse, tunnel, edifici, e tubi, gli ingressi e le uscite dovrebbero essere chiusi. Morsetti e fissaggi per Cavi AC unipolari non dovrebbe avere un circuito magnetico chiuso composto da ferro.

Trasporto con servizio professionale

Spedizione dell'ordine del cavo ZMS

VERI Cable ha diversi modi per proteggere i tuoi cavi, con imballaggio di spedizione robusto e professionale e assicurazione completa. Prima della spedizione, Nostro cavi sono confezionati in bobine di legno e bobine di scatole di cartone ondulato. Durante il trasporto, per proteggere le estremità del cavo dall'umidità, li sigilliamo con nastro autoadesivo BOPP e non igroscopico.

Ordini di cavi ZMS confezionati in fusti personalizzabili

Se ci sono problemi di qualità come imballaggio danneggiato e danni alla superficie del prodotto sul posto al ricevimento della merce, se la merce è confermata come vera, la merce non corrisponde all'ordine, e i problemi di qualità riscontrati dal cliente durante l'installazione, si confermano i problemi di qualità del prodotto stesso il processo di posa e di utilizzo, Se la consegna non è conforme ai requisiti contrattuali, Per favore contatta la nostra azienda direttamente.

    Non esitate a fornire la vostra richiesta nel modulo sottostante.

    E-mail*:

    Nome*:

    Paese*:

    TELEFONO*:

    Preventivo gratuito*: