Application and Function of Overhead Cable

Overhead transmission lines are generally composed of foundations, towers, hardware, insulators, 전선, ground wires (포함 OPGW 광케이블), and grounding facilities. Above the conductors of overhead transmission lines, the power lines erected to avoid direct lightning strikes on the conductors of the transmission lines are both overhead ground wires (referred to as ground wires), also known as lightning protection wires. In addition to lightning protection, overhead ground wires also play an important role in short-circuit current shunting.

The Difference of Overhead Line and Power Cable

Overhead line: bare metal conductor, erected in the air, fixed on the tower with insulator strings, and insulated by air. Main advantage: 저렴한 비용. The disadvantage is that it occupies a lot of land resources (line corridors), which affects the appearance of the city.

Power cable: Insulating medium is used to isolate the metal conductor from the outside world, and it is laid on the ground or underground. The main advantage is that it is more convenient to lay, occupies less land resources, and does not affect the appearance of the city. The disadvantage is that the cost is too high. In terms of safety, the industry currently believes that due to materials and manufacturing processes, the safety of overhead lines is better than that of power cables, and its failure rate is far lower than that of power cables.

The Function of the Overhead Ground Wire

It reduces the chance of lightning strikes the wire directly, and reduces the lightning overvoltage amplitude that the line insulation withstands. When the lightning strikes the top of the tower or the ground wire, the potential of the tower body is very high, and the voltage applied to the insulator string is equal to the difference between the potential of the tower body and the conductor potential. This voltage is generally much higher than the voltage on the insulator string when the lightning strikes the conductor directly. 낮은, will not cause flashover discharge. 하지만, if the grounding resistance is large, the potential of the tower body will be very high, and a reverse flashover will occur at this time, which is commonly referred to as “counterattack”.

It has a coupling effect on the wire. When lightning strikes the top of the tower or the ground wire, the potential of the wire will rise due to coupling, so the coupling can reduce the voltage on the insulator string. 그러므로, in order to reduce the “counterattack”, when it is difficult to reduce the grounding resistance, you can use the shunting and coupling properties of the overhead ground wire to add a coupled ground wire under the wire.

Since the lightning protection wire is grounded, it can shield the effect of the induction lightning on the wire and reduce the overvoltage of the induction lightning.

Here at Veri Cabke, you can get more information about cables. 에 오신 것을 환영합니다 저희에게 연락주세요.

ZMS Cable F

Recent Posts

What is the Difference Between H05RR-F & H05RN-F & H07RN-F in the Rubber Cable?

When choosing the right rubber cable for an electrical engineering project, it is critical to

6 days ago

행복한 중국 신년! —— ZMS 케이블

친애하는 파트너와 고객: 1 월 29 일, 2025 중국 달은 새해입니다 – Spring

2 months ago

벌거벗은 구리선과 에나멜 구리선의 차이점은 무엇입니까?

구리선은 전기 공학 및 전자 분야의 기본 구성 요소입니다., valued

2 months ago

엄숙한 성명 & 발표 —— ZMS 케이블

공지사항 고객 및 파트너 여러분께, 최근에, there has been sufficient evidence that other

3 months ago

2025 새해 복 많이 받으세요!

새해를 맞아 2025, ZMS Cable wishes every customer and partner a

3 months ago

유럽의 의료용 광섬유 시장에 대한 강력한 수요 추세

유럽의 의료 산업은 최근 몇 년 동안 상당한 발전을 이루었습니다., driven by the integration

4 months ago