전압 정격 동축 접지 케이블

전압 레벨 coaxial grounding cable should be determined according to the induced potential of the cable line. According to the past design experience, the voltage level of the coaxial grounding cable is generally 10kV; the cross-section of the coaxial grounding cable should be strictly selected according to the grounding current of the cable line. 하지만, in actual work, due to the lack of data and the complexity of calculation. The main models are VOV, YJOV, and YOY.

Scope of Use

High-voltage cables are designed according to single-loop, double-loop, or even more loops. If the length of a single cable is longer, the induced potential will be larger. It is best not to exceed 50v, 즉, the voltage of 50 volts without protection devices. But if there are protective devices, such as return lines, 동축 케이블, 등., it should not exceed 300v.

The coaxial grounding cable is generally used for the lead wire of the arrester and the grounding wire of the lightning protection, and the grounding box of the line sheath insulation protection device of the cross-linked cable is connected. 임피던스, coaxial ground cables have low impedance characteristics for transients.

VOV (YOV YJOV) is generally used for cross-connection of 고전압 cables to reduce the induced potential of the metal sheath. The protection box used for the 110KV~220KV cross-linked cable line sheath insulation protection device is connected with the transposition box. It is used for ground connection in transmission and distribution lines, and connection in cross-connect boxes. The inner and outer conductors of the coaxial cable are connected reasonably and conveniently and are reliable in use.

Conditions of Use

1. The maximum allowable working temperature of the conductor: is 90℃.

2. The bending radius is not less than 20 케이블 외경의 곱.

3. The ambient temperature should not be lower than 0℃ when laying the coaxial grounding power cable.

4. The power frequency rated voltage 8.7/10KV transmission and distribution line (110kv ~ 220KV) is grounded.

5. The connection wire between the metal sheath of the cable or the voltage limiter of the shielding layer shall meet the following requirements: 첫 번째, the connecting line should be the shortest, and coaxial cable should be used above 3m. 두번째, the insulation level of the connecting wire shall not be less than the insulation level of the outer sheath of the cable. Thirdly, the cross-section of the connecting line should meet the thermal stability requirements when the single-phase grounding fault current of the system passes through.

ZMS Cable F

Recent Posts

What is the Difference Between H05RR-F & H05RN-F & H07RN-F in the Rubber Cable?

When choosing the right rubber cable for an electrical engineering project, it is critical to

2 weeks ago

행복한 중국 신년! —— ZMS 케이블

친애하는 파트너와 고객: 1 월 29 일, 2025 중국 달은 새해입니다 – Spring

2 months ago

벌거벗은 구리선과 에나멜 구리선의 차이점은 무엇입니까?

구리선은 전기 공학 및 전자 분야의 기본 구성 요소입니다., valued

3 months ago

엄숙한 성명 & 발표 —— ZMS 케이블

공지사항 고객 및 파트너 여러분께, 최근에, there has been sufficient evidence that other

3 months ago

2025 새해 복 많이 받으세요!

새해를 맞아 2025, ZMS Cable wishes every customer and partner a

3 months ago

유럽의 의료용 광섬유 시장에 대한 강력한 수요 추세

유럽의 의료 산업은 최근 몇 년 동안 상당한 발전을 이루었습니다., driven by the integration

4 months ago