번역


+86-371-67829333

소식

What are RVV and RVVP Flexible Control Cables?

What is An RVV Control Cable?

RVV control cable is known as copper core PVC insulated PVC sheathed flexible cable. It is also known as light polyvinyl chloride sheathed flexible cable, referred to as soft sheathed cable, is a kind of sheathed cable.

Because it is a soft core, RVV is generally used in narrow areas or places where it needs to be bent frequently. Mainly used in electrical appliances, 미터, electronic equipment, and automation devices with power lines, control lines, and signal transmission lines, specifically for burglar alarm systems, building intercom systems, 등.

Use Characteristics

Rated working voltage: 300/500다섯

The long-term allowable working temperature of the cable is not higher than 70℃.

The maximum temperature of the cable conductor in case of a short circuit (the longest duration does not exceed 5s) does not exceed 160℃.

The ambient temperature when the cable is laid should be no less than 0℃, 그렇지 않으면, it needs to be preheated beforehand.

Installation Bending Radius

ㅏ) The cable without an armor layer should be not less than 6 케이블 외경의 곱.

비) Cable with an armored or copper tape shielding structure should be not less than 12 케이블 외경의 곱.

기음) flexible cable with shielding structure, should be not less than 6 케이블 외경의 곱.

What is RVVP Control Cable?

RVVP is a kind of cable with soft conductor PVC insulation plus a shield and PVC sheath. Copper-core PVC insulated shielded PVC sheathed flexible cable, also known as electrical connection anti-interference flexible cable.

The “P” in RVVP refers to shielding, that is to say, RVVP wire has a shielding layer, and RVVP has a stronger anti-interference ability for external signals.

Rated voltage 300/300V, the number of cores commonly used is 2-19 코어.

Commonly used core wire diameter: 0.3 square, 0.5 square, 1 square, 1.5 square, 2.5 square, 4 square.

RVVP Cable Introduction

  1. RVVP implementation standard JB/T8734.5-2012
  2. Polyvinyl chloride insulation
  3. PVC sheath
  4. The conductor is a copper core stranded
  5. Aluminum alloy braided shielding network
  6. The rated voltage is 300/300V
  7. The normal working temperature is not more than 70℃
  8. The maximum temperature of the cable conductor does not exceed 160℃ during a short circuit (the longest duration does not exceed 5s). The ambient temperature when the cable is laid should be no less than 0℃, 그렇지 않으면, it needs to be preheated beforehand.

RVVP Cable Application

The role of cable shielding is mainly to prevent the interference of external interference sources to the cable itself and the interference caused by the cable to other circuits. The use of a shielded cable and reliable grounding of the shielding layer is an effective measure to suppress its electromagnetic interference.

It is suitable for communication, 오디오, broadcasting, audio systems, burglar alarm systems, intelligent automation systems, automatic meter reading systems, fire-fighting systems, and other needs to prevent interference line connection, efficient and safe transmission data cable.

Talk About The Life Of The Control Cable

The service life of control cables is determined by the air oxidation induced period of the sheath raw materials. 그만큼 general control cable is designed to be used for 20 연령, which is the maximum life span of the control cable. Although it is possible to go longer in specific daily life, the design duration is the maximum life of control cables from a safety point of view.

The Life Of Control Cables

The elements that endanger the life of the control cable and the way to increase the life of the control cable.

  1. The control cable does not have to return to moisture, so as not to encounter heat and is subject to leaching. As the cable sheath on the cable is certain maintenance effectiveness, so the heat, and corrosion of the cable are more dangerous.
  2. Control cables do not have to overload applications. Overload application of the cable will lead to immediate damage to the cable insulation and sheathing, endangering the cable life or immediately destroying the cable.
  3. The old engineering building routes were found to be engulfed by water or wet. In particular, if the route is worn out to produce embrittlement should immediately ask the welders to give repair.
  4. Control cable to prevent common cable connector failure, common cable connector failure will lead to cable short-circuit failure, not only does the cable leads to damage, and even destroy household appliances.
  5. Control cable commodity itself: as far as possible to select the national industry standard cable, the cost-effective non-standard cable is very easy to lead to short-circuit failure, and non-standard cable life itself is short.
  6. Control cable belongs to the natural environment and temperature. Control cable is located in the external natural environment and heat sources can also lead to high-temperature control cables, insulation penetration, and even explosive fires.
ZMS Cable F

Recent Posts

What Industry Cables Are Used in a Rocket Launch from Start to Finish?

The successful launch of a rocket involves one of the most complex engineering feats imaginable,…

8 hours ago

광섬유 케이블을 생산하는 데 어떤 광섬유 재료가 사용됩니까??

광섬유 케이블은 현대 통신의 중추가 되었습니다., offering high-speed data transmission over

2 weeks ago

일반적으로 고전압 구리 케이블의 코어 수는 몇 개입니까?? 응용 프로그램은 무엇입니까?

고전압 구리 케이블은 전력 분배 및 전송에 필수적인 구성 요소입니다.,…

1 month ago

철도 시스템에 사용되는 고전압 선은 무엇입니까?

Railroad high voltage lines play a vital role in powering the railway systems that transport

2 months ago

단일 모드와 다중 모드 광섬유 케이블의 차이점은 무엇입니까?

광섬유 케이블은 현대 통신 네트워크의 중요한 구성 요소입니다., enabling high-speed data transmission over

2 months ago

What are the Common Types of Control Cables Used in Industrial Applications?

Control cables are essential components in industrial applications, facilitating communication, 신호 전송, and control between

2 months ago