번역


+86-371-67829333

소식

What is the solar cable? What are the considerations when selecting one?

Building cost-effective and profitable photovoltaic power plants represents the most important goal and core competence of all solar cable manufacturers.

Profitability depends not only on the efficiency or high performance of the solar modules themselves, but also on a series of components that on the surface do not appear to be directly related to the modules.

예를 들어, if a PV plant fails to use the right cables, the lifetime of the entire system will be affected.

그래서, what is a PV cable?

PV cable is an electron beam cross-link cable rated at 120 ℃. This rating corresponds to 18 years of service at a continuous temperature of 90 ℃. And it lasts longer when the temperature is below 90 ℃.

Solar cells are currently used mainly in silicon solar cells, which dominate the applications.

그만큼 characteristics of solar cables are determined by their special cable insulation and sheathing material, called cross-linked PE. Which is irradiated by an irradiation gas pedal to change the molecular structure of the cable material and thus provide its individual properties. During installation and maintenance, the cable can be routed on the sharp edges of the roof structure. While the cable is subjected to pressure, 굽힘, tension, cross-tension loads, and strong impacts.

If the cable sheath is not strong enough, the cable insulation will be severely damaged. Thus affecting the life of the entire cable, or leading to short circuits, fires and injuries, and other dangerous problems.

In addition to the main equipment in the construction process of solar photovoltaic power plants. Such as photovoltaic modules, inverters, and step-up transformers. In addition to supporting the connection of solar cable materials to the overall profitability of photovoltaic power plants. The safety of operation, whether efficient, also plays a vital role.

The following is a detailed introduction to the common cables and materials used in photovoltaic power plants and their use of the environment.

Cables according to the photovoltaic power plant system can be divided into DC cables and AC cables, according to the use and use of different environments are classified as follows:

DC 기음자제

1 Series cables between components and modules.

2 Parallel cables between strings and between strings and the DC distribution box.

3 Cable between DC distribution box and inverter.

The above cables are DC cables, which are more often laid outdoors and need to be moisture-proof, sunproof, cold-proof, heat-proof, and UV-proof. And in some special environments, they also need to be protected from chemicals such as acids and alkalis.

교류 기음able

1 Inverter to step-up transformer connection cable.

2 The connection cable from the step-up transformer to the distribution unit.

3 The connection cable from the distribution unit to the grid or the customer.

This part of the cable is an AC load cable, the indoor environment laying more, can be selected following the general power cable selection requirements.

Photovoltaic Special 기음able

Solar power photovoltaic power stations in numerous DC cables to be laid outdoors, in harsh environmental conditions. The cable material should be based on resistance to ultraviolet light, ozone, severe temperature changes, 그리고 화학적 침식.

Common material cable in this environment for a long time will lead to the cable sheath being fragile, and even decomposing the cable insulation layer.

These conditions can directly damage the cable system and also increase the risk of short-circuiting the cable.

In the medium to long term, the possibility of fire or injury to personnel is also higher, greatly affecting the service life of the system. 그러므로, it is essential to use PV-specific cables and components in PV power plants.

PV-specific cables and components are not only optimally resistant to weathering, 자외선, and ozone attack, but can also withstand a greater range of temperature variations.

Photovoltaic cable conductor material is generally copper conductor or tinned copper conductor.

Solar 기음able Selection

The cables used in the low-voltage DC transmission part of a solar PV power system have different requirements for the connection of different components. Because of the use environment and technical requirements.

The overall factors to be considered are cable insulation performance, heat and flame resistance, aging performance, and wire diameter specifications.

Specific requirements are as follows:

1 Connecting 기음able between hotovoltaic 기음ell 기음omponents

Generally use the connection cable attached to the module junction box to connect directly, the length is not enough to use a special extension cable.

Depending on the size of the component power, this type of connection cable has a cross-sectional area of 2.5 m㎡, 4.0 m㎡, 6.0 m㎡, and other three specifications.

This type of connection cable uses a double layer of insulation sheath. Which has superior resistance to ultraviolet light, 물, ozone, 산, and salt erosion, superior all-weather capability, and wear resistance.

2 Connection 기음able between attery and nverter

It is required to use UL-tested multi-strand flexible cable and connect as close as possible.

Choosing short and thick cables can reduce the loss of the system, improve efficiency and enhance reliability.

3 Connecting 기음ables between attery 에이rray and 기음ontroller, 등.

It is also required to use UL-tested multi-stranded flexible cable, and the cross-sectional area is based on the maximum output current of the array.

The DC cable cross-sectional area of each part is determined according to the following principles:

For the connection cable between solar modules and components, the connection cable between battery and battery. And the connection cable for AC load, the cable current rating is generally selected as 1.25 times the maximum continuous operating current in each cable.

The connection cables between solar cell arrays and arrays, the connection cables between battery banks and inverters. 일반적으로, the selected cable-rated current is 1.5 times the maximum continuous operating current in each cable.

The above is a general introduction to solar cables, as well as some considerations when shopping for cables. ZMS cable manufacturer promises to have solar cables manufactured to international standards, as well as a variety of components and complete services. If you have any questions about the purchase of solar cables, please feel free to consult us. And we will have a professional cable sales representative to help you.

ZMS Cable F

Recent Posts

What is the Difference Between H05RR-F & H05RN-F & H07RN-F in the Rubber Cable?

When choosing the right rubber cable for an electrical engineering project, it is critical to

1 week ago

행복한 중국 신년! —— ZMS 케이블

친애하는 파트너와 고객: 1 월 29 일, 2025 중국 달은 새해입니다 – Spring

2 months ago

벌거벗은 구리선과 에나멜 구리선의 차이점은 무엇입니까?

구리선은 전기 공학 및 전자 분야의 기본 구성 요소입니다., valued

2 months ago

엄숙한 성명 & 발표 —— ZMS 케이블

공지사항 고객 및 파트너 여러분께, 최근에, there has been sufficient evidence that other

3 months ago

2025 새해 복 많이 받으세요!

새해를 맞아 2025, ZMS Cable wishes every customer and partner a

3 months ago

유럽의 의료용 광섬유 시장에 대한 강력한 수요 추세

유럽의 의료 산업은 최근 몇 년 동안 상당한 발전을 이루었습니다., driven by the integration

4 months ago