Instrumentation Cable

To date, VERI Cable has produced instrumentation cables for use in a variety of applications, including fully automated production, power equipment, tunnel lighting, or laying into cable trenches. The length of the cables sold reaches ຫຼາຍກວ່າ 50,000 meters, and their resistance to moisture and corrosion is widely appreciated.

Instrumentation cables manufactured by VERI Cable are certified to GB, IEC, BS, ASTM, ISO900, ISO14000, ISO14001, ISO18000, BS, CE, IEC, NFC, ASTM and DIN.

ສອບຖາມດຽວນີ້

ສອບຖາມດຽວນີ້

CU/XLPE Insulated Instrument Cable---0.6/1KV

450/750v 0.5mm2 0.75mm2 1mm2 CU/XLPE insulated instrumentation cable

Construction
Conductor: Annealed or tinned copper
Pairing: Two or three insulated conductors uniformly twisted together with a lay not exceeding 100 ມມ
Binder Tape: PETP transparent tape
ມາດຕະຖານ
IEC 60502, BS 5308, GB 9330

Shielding

Braid

Jacket/Insulation

PVC/XLPE/PE

Rated Voltage

600ວ

ຂະໜາດ

0.5mm2-1000mm2 customizable

ປະເພດ

Low Voltage/Medium Voltage/High Voltage

Certificate

ISO, CCC, CE, VDE

ປະເພດຕົວນໍາ

flexible

ກາບ

PVC Sheath

Sheath Color

Black or blue

Advantages:
Fire prevention, anti-impact, anti-rat, anti-mosquito, anti-radiation
Low working temperature
Strong overload resistance
Long service life, high safety, ການລະເບີດ, corrosion resistance
High mechanical strength

Typically used in industrial process manufacturing plants for communications, data, and voice transmission of signals and services, and also for the interconnection of electrical equipment and instruments, usually in the oil industry.

Copper Tape Screened Twisted Pair Instrument Cable

Individual Screen Armored Instrument Cable application:
Instrumentation cable Individual and overall Screened Steel Wire Armored/ SWA Pairs are used in data processing and process control. Suitable for fixed installations in damp locations and open spaces. The electrostatic screen protects against outer interference fields.

1. Design: LSZH (Low Smoke Zero Halogen) Instrumentation cable consisting of bare copper conductors, black & white, twisted pairs or black, white & red twisted triples with a continuous number sequence.

2. Voltage Rating: Rated Voltage Max. 300V a.c; Nominal Voltage A.C/D. C 110/150V, Test Voltage In process spark test – 4500V and AC withstand

voltage test – 1500V, TECHNICAL DATA 0.5mm 1.5mm

3. Operating Temperature: Minimum continuous operating temperature -25°C,75°C, 90°C, Minimum short circuit temperature 160°C (for 5 sec)

ວັດສະດຸ Conductor

Copper/copper aluminum tinned copper wire aluminum alloy

ວັດສະດຸ insulation

PVC/XLPE

Shielding

Foil

ເສື້ອກັນໜາວ

PVC

ສີ

all kinds of color is available

ມາດຕະຖານ

IEC BS ASTM DIN GB9330-1998

Sectional area

0.75 ມມ2 – 10 ມມ2

armored

steel tape steel wire

Inner Sheath

LSZH (Low Smoke Zero Halogen) ກາບ

Outer Sheath

LSZH (Low Smoke Zero Halogen) Sheath is flame retardant, conforms to IEC60332-3-22, halogen-free, conforms to IEC60754-1, low smoke emissions, conforms to IEC61034-1-2

Conductor sizes

0.5 mm² solid, 1.0 mm² solid, 0.5 mm² flexible, 0.75 mm² flexible or 1.5mm²stranded

Collective screen

24 µm aluminum / PETP tape over tinned copper drain wire, 0.5 mm²

Maximum Capacitance:
Conductor to Conductor 145pF/m 200pF/m, Conductor to Screen 240pF/m 300pF/m, Maximum Conductor Resistance @ 20 C 38.4Ω/km 13.8Ω/km,
Insulation Resistance @ 20 C 40MΩ/km 140MΩ/km, Cross Talk Attentuation Between Pairs @ 1kHz 300Ω 150Ω
Inductance @ 1kHz 1.00mH/km 0.95mH/km, L/R Ratio @ 1kHz 13.7µH/Ω 36.5µH/Ω
Bending Radius:
The following minimum bending radius should be observed to ensure operating reliability
unarmoured: 9 x cable outer diameter (during installation) 6 x cable outer diameter (after installation)
Armoured: 18 x cable outer diameter (during installation) 12 x cable outer diameter (after installation)

Underwater Instruments Flat Shaft Electrical Cable

This product can be used as an underwater communication cable. It can be either a single network cable structure a coaxial cable structure, a network cable plus multicore power cable, or a coaxial cable plus multicore control cable structure. The network cable is more than Category 5 or Category 6, and the video cable is commonly used as 75-3/75-5, ແລະອື່ນໆ. This product can also be used as an underwater telephone line. When using it, you can choose 2 pairs to use as video recording lines, and you can choose any pair to use as a telephone line or as a communication cable. It is simple to use and convenient to maintain.

Characteristics of Underwater Network Cable:
It is resistant to underwater pressure, seawater corrosion, underwater low temperature, oil, cold, corrosion, UV, abrasion, flame retardant, and bending. It applies to the rapid movement and installation of instruments and equipment in the underwater field.

Conductor

multi strand super fine stranded oxygen free copper wire

ວັດສະດຸ insulation

high-densitywaterproof material

Shielding

tinned copper wire fabric

ເສື້ອກັນໜາວ

seawater resistant polyurethane

ສີ

core wires are distinguished by different colors

Network cable type

CAT5E/CAT6/CA6A

ຄວາມແຮງ tensile

100/300/500KGcustomized

ແຮງດັນທີ່ຈັດອັນດັບ

300/300ວ

Collective screen

24 µm aluminium / PETP tape over tinned copper drain wire, 0.5 mm²

Water depth

100M/200m/500m, ແລະອື່ນໆ

Temperature range of underwater network cable:
Fixed installation – 40 ℃ to+85 ℃
Mobile installation: – 30 ℃ to+85 ℃

Bending radius of zero buoyancy steel wire mesh:
Fixed installation: 5 × Cable outer diameter (ງ)
Mobile installation: When the strokeis<10m, the bending radius is 7.5 × D When the stroke is ≥ 10m, the bending radius is 10 × D

Instrument Cable Installation and Wiring Tips

  1. —Under the eaves. Standard cables can be used only if the cable is not exposed to direct sunlight or extreme heat, and conduit is recommended. Do not use cables without UV protection in direct sunlight.
  2. —On the outer wall. Avoid direct sunlight on the wall and man-made damage. Heating cables are exposed to high temperatures in metal conduit or trunking, and many polymeric materials experience reduced service life at these temperatures.
  3. —In pipes (plastic or metal). If in pipes, pay attention to the damage to plastic pipes and the heat conduction of metal pipes. Once mechanical damage occurs, fiber optic cables are expensive to repair, requiring at least two terminations at each discontinuity point.
  4. —Suspended applications/overhead cables. Consider cable sag and stress. The cable is exposed to direct sunlight or not.
  5. —Directly laying in the underground cable trench, this environment is the smallest control range. The installation of the cable trench should be checked regularly for dryness or dampness. If the shield of the control cable needs to be grounded, the appropriate standards must be followed.

VERI Transportation with Professional Service

VERI Cable has multiple ways to protect your cables, ດ້ວຍການຫຸ້ມຫໍ່ການຂົນສົ່ງທີ່ທົນທານແລະເປັນມືອາຊີບແລະການປະກັນໄພທີ່ສົມບູນແບບ. ກ່ອນການຂົນສົ່ງ, our cables are packaged in wooden reels and corrugated box coils. ໃນລະຫວ່າງການຂົນສົ່ງ, ເພື່ອປົກປ້ອງປາຍສາຍຈາກຄວາມຊຸ່ມຊື່ນ, ພວກເຮົາປະທັບຕາພວກມັນດ້ວຍ BOPP tape-adhesive ແລະບໍ່ hygroscopic.

ຖ້າມີບັນຫາດ້ານຄຸນນະພາບເຊັ່ນການຫຸ້ມຫໍ່ທີ່ເສຍຫາຍແລະຫນ້າດິນຂອງຜະລິດຕະພັນເສຍຫາຍໃນຈຸດເວລາທີ່ສິນຄ້າໄດ້ຮັບ, ຖ້າສິນຄ້າຖືກຢືນຢັນວ່າເປັນຄວາມຈິງ, ສິນຄ້າບໍ່ກົງກັບຄໍາສັ່ງ, ແລະບັນຫາຄຸນນະພາບທີ່ລູກຄ້າພົບເຫັນໃນລະຫວ່າງການຕິດຕັ້ງ, ຂັ້ນຕອນການວາງແລະການນໍາໃຊ້ແມ່ນໄດ້ຮັບການຢືນຢັນວ່າເປັນບັນຫາທີ່ມີຄຸນນະພາບຂອງຜະລິດຕະພັນຂອງມັນເອງ, ຖ້າການຈັດສົ່ງບໍ່ສອດຄ່ອງກັບຂໍ້ກໍານົດຂອງສັນຍາ, ກະລຸນາ ຕິດຕໍ່ບໍລິສັດຂອງພວກເຮົາ ໂດຍກົງ.

    ກະລຸນາຮູ້ສຶກວ່າບໍ່ເສຍຄ່າເພື່ອສະຫນອງການສອບຖາມຂອງທ່ານໃນແບບຟອມຂ້າງລຸ່ມນີ້.

    ອີເມວ(ຕ້ອງການ)*:

    ຊື່​ຂອງ​ເຈົ້າ(ຕ້ອງການ):

    ປະ​ເທດ​ຂອງ​ເຈົ້າ:

    ໂທ*:

    ຂໍ້ມູນ*: