AAC AAAC ACSR
VERI kabel, according to different uses, produces a variety of overhead cables. Including AAC, AAAC, ACSR, ABC cable –aerial bundled cable, og så videre. Our range of overhead lines generally contains aluminum conductors or aluminum alloy conductors to meet all customer needs. We specialize in providing excellent overhead lines for transmission, distribution, and power network industries. And other cable products such as voltage cables, submarine cables, fiber cables, spesielle kabler, og så videre. So please kontakt oss with your requirements. Også, we will reply to you the detailed information that you want.
Types of VERI AAC AAAC ACSR
All Aluminum Conductor—AAC
DATA Aluminum Alloy Dirigent is the main component of the overhead power line. Its function is to transmit current and electric power. These bare conductors are suitable for low, medium, and high-voltage overhead lines. AAC is widely used in urban areas, where the span is usually short. But the conductivity requirements are high.
STANDARDER&REFERANSER:ASTM—B 230, ASTM—B 231, DIN48201, BS215 (Or producing by the standard of the customer’s country)
- Phase conductors: round stood or compacted 1350-H19 aluminum or copper conductor, AAAC, ACSR
- Neutral or messenger conductor: round stood or compacted 6201 aluminum alloy or AAC, ACSR
- Street lighting conductor: round stood or compacted aluminum conductor
- Isolasjon: LDPE, HDPE, XLPE, PVC
Manufacturing Standards
Conductor Size | Code Words | Klasse | Required Construction | Masse | Vurdert styrke | |||||
Cmils or AWG | mm² | Ingen. of Wires | Diameter of Wire | Per 1000ft, lb | Per km, kg | kips | kn | |||
I. | mm | |||||||||
3500000 | 1773 | Bluebonnet | EN | 127 | 0.1660 | 4.22 | 3345 | 4977 | 58.7 | 261 |
3000000 | 1520 | Trillium | EN | 127 | 0.1537 | 3.90 | 2840 | 4226 | 50.3 | 223 |
2750000 | 1393 | Bitterroot | EN | 91 | 0.1738 | 4.42 | 2602 | 3872 | 46.1 | 205 |
2500000 | 1267 | Lupine | EN | 91 | 0.1657 | 4.21 | 2365 | 3519 | 41.9 | 186 |
2250000 | 1140 | Sagebrush | EN | 91 | 0.1572 | 3.99 | 2128 | 3166 | 37.7 | 167 |
2000000 | 1013 | Cowslip | EN | 91 | 0.1482 | 3.77 | 1873 | 2787 | 34.2 | 153 |
1750000 | 886.7 | Jessamine | AA | 61 | 0.1694 | 4.30 | 1641 | 2442 | 29.7 | 132 |
1590000 | 805.7 | Coreopsis | AA | 61 | 0.1614 | 4.10 | 1489 | 2216 | 27.0 | 120 |
1510500 | 765.4 | Gladiolus | AA,EN | 61 | 0.1574 | 4.00 | 1417 | 2108 | 25.6 | 114 |
1431000 | 725.1 | Carnation | AA,EN | 61 | 0.1532 | 3.89 | 1342 | 1997 | 24.3 | 108 |
1351000 | 694.8 | Columbine | AA,EN | 61 | 0.1488 | 3.78 | 1266 | 1884 | 23.4 | 104 |
SØKNAD
All aluminum conductors belong to bare conductors, which mainly play the role of transmitting electrical energy. Based on different voltages, the wire cross-sectional area is also different. AAC cable is commonly used for general distribution lines with a small force and small span. But it is not allowed to contact with trees.
All Aluminum Alloy Conductor—AAAC
Dirigent: Hard-Drawn 1350-H19 Aluminum Wires, Minimum Purity 99.45%.
Reinforcement: Galvanized Steel Wires (Zinc-Coated)
Best Seller: Turkey, Sparrow, Raven, Penguin, Waxwing, Dove, Rail, Pheasant, Martin
Konstruksjon (Aluminum/Steel): 6/1, 7/1, 8/1, 12/7, 16/19, 24/7, 26/7, 30/7, 30/19, 36/1, 45/7, 54/7, 54/19, 72/7, 76/19, 84/19
Cross-Sectional Area: 6~4/0 awg, 80~2312 mcm (80~211.3 mcm for Standard High-Strength Conductor).
Galvanization: Class A, B or C
Grease Corrosion Protection: Available upon Request
Specifications
AAAC bare conductor meets the following ASTM specifications :
B-398 Aluminum Alloy 6201-T81 Wire for Electrical Purposes
B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
The Part of AAAC-ASTM-B399 Technical Data:
Stranding | Diameter of conductor | Linear mass | Rated strength | D.C. resistance at 20℃ |
No./mm | mm | Kg/km | kgf | Ω/km |
6 | 7/1.55 | 4.65 | 36.44 | 422 |
7/1.68 | 5.04 | 42.7 | 502 | |
4 | 7/1.96 | 5.89 | 57.89 | 685 |
48.69(4) | 7/2.12 | 6.35 | 67.56 | 799 |
2 | 7/2.47 | 7.42 | 92.14 | 1091 |
77.47(2) | 7/2.67 | 8.02 | 107.50 | 1275 |
1/0 | 7/3.12 | 9.35 | 146.50 | 1733 |
123.3(1/0) | 7/3. 37 | 10.11 | 171.00 | 2019 |
2/0 | 7/3.50 | 10.52 | 184.70 | 2090 |
155.4(2/0) | 7/3.78 | 11.35 | 215.16 | 2447 |
3/0 | 7/3.93 | 11.79 | 232.70 | 2641 |
195.7 (3/0) | 7/4.25 | 12.75 | 271.50 | 3079 |
4/0 | 7/4.42 | 13.26 | 293.70 | 3334 |
246.9 (4/0) | 7/4.77 | 14.30 | 342.60 | 3885 |
Søknad:
Used as bare overhead conductor for primary and secondary distribution. The AAAC conductor is designed to get a better strength-to-weight ratio and offer improved electrical properties, excellent sag-tension characteristics, and superior corrosion resistance when compared with ACSR. As compared to a conventional ACSR conductor, the lighter weight, comparable strength & current carrying capacity, lower electrical losses, and superior corrosion resistance have given AAAC a wide acceptance in the distribution and medium & high voltage transmission lines.
Aluminum Conductor Steel Reinforced—ACSR
ACSR conductor has the advantages of simple structure, convenient erection and maintenance, low line cost, and large transmission capacity. And they are convenient for laying across special geographical conditions. Such as rivers and valleys, good electrical conductivity, and sufficient mechanical.
Design
1 Aluminum conductor with increased breaking load, round stranded compressed (RM)
2 Core insulation (XPLE black, UV-resistant, not flame retardant); 2 up to 4 cores of the equal cross-section are stranded together in left-hand lay, additionally 1 eller 2 cores of the reduced cross-section can be co-stranded.
STANDARDER&REFERANSER:ASTM—B 230, ASTM—B 231, DIN48201, BS215 (Or producing by the standard of the customer’s country)
ACSR Technical Characteristics / U.S.A Sizes – ASTM B232
Area | Stranding and diameter | Approximate overall diameter | ||||
Aluminum | Steel | Total | Aluminum | Steel | ||
AWG or MCM | mm2 | mm2 | mm2 | mm | mm | mm |
8 | 8.34 | 1.39 | 9.73 | 6/1.33 | 1/1.33 | 3.99 |
6 | 13.29 | 2.19 | 15.48 | 6/1.68 | 1/1.68 | 5.04 |
4 | 21.16 | 3.55 | 24.71 | 6/2.12 | 1/2.12 | 6.36 |
4 | 21.16 | 5.35 | 26.50 | 7/1.96 | 1/2.61 | 6.53 |
3 | 26.69 | 4.45 | 31.14 | 6/2.38 | 1/2.38 | 7.14 |
2 | 33.61 | 5.61 | 39.22 | 6/2.67 | 1/2.67 | 8.01 |
2 | 33.61 | 8.52 | 42.13 | 7/2.47 | 1/3.30 | 8.24 |
1 | 42.39 | 7.10 | 49.49 | 6/3.00 | 1/3.00 | 9.00 |
0 | 53.48 | 8.90 | 62.38 | 6/3.37 | 1/3.37 | 10.11 |
2/0 | 67.42 | 11.23 | 78.65 | 6/3.78 | 1/3.78 | 11.34 |
3/0 | 85.03 | 14.19 | 99.22 | 6/4.25 | 1/4.25 | 12.75 |
4/0 | 107.23 | 17.87 | 125.10 | 6/4.77 | 1/4.77 | 14.31 |
Application of ACSR
1. The higher-strength ACSR conductors are widely used in power transmission lines with various voltage levels.
2. The higher-strength ACSR conductors are commonly used for river crossings, overhead earth wires, and installations involving extra-long spans.
3. The higher-strength ACSR conductors are also suitable for laying across rivers and valleys where special geographical features exist.
Utmerket service av VERI Cable
Eksporter erfaring
Som en profesjonell kabelprodusent, våre kabelprodukter har blitt eksportert til mange land tidligere 30 år, inkludert USA, Canada, Spania, Storbritannia, Tyskland, Frankrike, Russland, Hellas, Saudi-Arabia, osv. I disse landene, våre kabelprodukter er svært populære blant kundene. Og hvert år, på grunn av vår gode kvalitet og service, vi vil få mange gode tilbakemeldinger fra våre kunder.
Tilpasset kabeltjeneste
Vårt utvalg av tilpassede tjenester inkluderer design, størrelse, og overflatefarge. Mange populære farger er også tilgjengelige for deg å velge. Vi er også spesialister på overkapping, for eksempel, vi kan lage tilpasset polyetylen (PE) og polyuretan (PUR) i henhold til dine krav. Vi kan tilby løsninger basert på dine ideer. Ta kontakt med oss for å gi oss ideen din.
Strenge kvalitetskontrollstandarder
Veri Cable offers a wide variety of power cables based on trends and personal preferences. Og vi leverer alle typer strømkabler, mer enn 100 serie. Da, for å sikre kvaliteten på kablene, vi insisterer på å teste produktene våre en gang i blant.