Instrumentation Cable
Instrumentation cables manufactured by VERI Cable are certified to GB, IEC, BS, ASTM, ISO900, ISO14000, ISO14001, ISO18000, BS, CE, IEC, NFC, ASTM and DIN.
To date, VERI Cable has produced instrumentation cables for use in a variety of applications and types, including fully automated production, power equipment, tunnel lighting, or laying into cable trenches. The length of the cables sold reaches mer enn 50,000 meter, and their resistance to moisture and corrosion is widely appreciated.
Types of Instrumentation Cables
CU/XLPE Insulated Instrumentation Cable---0.6/1KV
Konstruksjon
Dirigent: Annealed or tinned copper
Pairing: Two or three insulated conductors uniformly twisted together with a lay not exceeding 100 mm
Binder Tape: PETP transparent tape
Standard
IEC 60502, BS 5308, GB 9330
450/750v 0.5mm2 0.75mm2 1mm2 CU/XLPE insulated instrumentation cable
Shielding | Braid |
Jacket/Insulation | PVC/XLPE/PE |
Nominell spenning | 600V |
Størrelse | 0.5mm2-1000mm2 customizable |
Type | Low Voltage/Medium Voltage/High Voltage |
Certificate | ISO, CCC, CE, VDE |
Ledertype | flexible |
Slire | PVC Sheath |
Skjerpefarge | Black or blue |
Advantages:
Fire prevention, anti-impact, anti-rat, anti-mosquito, anti-radiation
Low working temperature
Strong overload resistance
Long service life, high safety, eksplosjonssikker, korrosjonsbestandighet
High mechanical strength
Typically used in industrial process manufacturing plants for communications, data, and voice transmission of signals and services, and also for the interconnection of electrical equipment and instruments, usually in the oil industry.
Copper Tape Screened Twisted Pair Instrument Cable
2. Spenningsklassifisering: Rated Voltage Max. 300V a.c; Nominal Voltage A.C/D. C 110/150V, Test Voltage In process spark test – 4500V and AC withstand
voltage test – 1500V, TECHNICAL DATA 0.5mm 1.5mm
3. Driftstemperatur: Minimum continuous operating temperature -25°C,75°C, 90°C, Minimum short circuit temperature 160°C (for 5 sec)
Ledermateriale | Copper/copper aluminum tinned copper wire aluminum alloy |
Isolasjonsmateriale | PVC/XLPE |
Shielding | Foil |
Jakke | PVC |
Farge | all kinds of color is available |
Standard | IEC BS ASTM DIN GB9330-1998 |
Sectional area | 0.75 mm2 – 10 mm2 |
armored | steel tape steel wire |
Inner Sheath | LSZH (Lite røyk null halogen) Slire |
Outer Sheath | LSZH (Lite røyk null halogen) Sheath is flame retardant, conforms to IEC60332-3-22, halogen-free, conforms to IEC60754-1, low smoke emissions, conforms to IEC61034-1-2 |
Conductor sizes | 0.5 mm² solid, 1.0 mm² solid, 0.5 mm² flexible, 0.75 mm² flexible or 1.5mm²stranded |
Collective screen | 24 µm aluminum / PETP tape over tinned copper drain wire, 0.5 mm² |
Underwater Instrumentation Flat Shaft Electrical Cable
This product can be used as an underwater communication cable. It can be either a single network cable structure a coaxial cable structure, a network cable plus multicore power cable, or a coaxial cable plus multicore control cable structure. The network cable is more than Category 5 or Category 6, and the video cable is commonly used as 75-3/75-5, osv. This product can also be used as an underwater telephone line. When using it, you can choose 2 pairs to use as video recording lines, and you can choose any pair to use as a telephone line or as a communication cable. It is simple to use and convenient to maintain.
Dirigent | multi strand super fine stranded oxygen free copper wire |
Isolasjonsmateriale | high-densitywaterproof material |
Shielding | tinned copper wire fabric |
Jakke | seawater resistant polyurethane |
Farge | core wires are distinguished by different colors |
Network cable type | CAT5E/CAT6/CA6A |
strekkfasthet | 100/300/500KGcustomized |
Nominell spenning | 300/300V |
Collective screen | 24 µm aluminium / PETP tape over tinned copper drain wire, 0.5 mm² |
Water depth | 100M/200m/500m, osv |
Bending radius of zero buoyancy steel wire mesh:
Fast installasjon: 5 × Cable outer diameter (D)
Mobil installasjon: When the strokeis<10m, the bending radius is 7.5 × D When the stroke is ≥ 10m, the bending radius is 10 × D
Selection Tip: Selection of Instrumentation Cables in the Petrochemical Industry
The petrochemical industry, as one of the large industrial fields, has a harsh working environment involving temperature, pressure, corrosiveness and other extreme conditions, which puts higher requirements on the selection and design of instrumentation cables.
Select from VERI Instrumentation Cables:
— Cable Material:
In the petrochemical industry, cables made of corrosion-resistant, high-temperature-resistant, fire-retardant and flame-retardant materials are the first choice. PVC is suitable for general processes, and polyethylene PE is the first choice for oil-, acid- and alkali-resistant. VERI cables can be customized to be made of high-temperature materials, slik som FEP, PFA, eller silicone rubber.
— Cable Specifications and Performance:
Konduktørstruktur | Logarithms | Maximum Nominal Outside Diameter (mm) | Nominal Weight (kg/km) |
1/0.8mm (0.5mm 2) | 2 5 10 20 30 | 9.7 12.9 17.7 22.9 27.3 | 100 190 320 570 820 |
16/0.2mm (0.5mm2) | 2 5 10 20 30 | 11.4 14.6 20.5 26.7 31.7 | 160 250 480 780 1100 |
24/0.2mm (0.75mm2) | 2 5 10 20 30 | 12.2 15.7 21.8 28.5 33.7 | 190 270 550 960 1320 |
1/1.13mm (1.0mm2) | 2 5 10 20 30 | 12.2 15.6 22.0 29.2 34.8 | 190 270 480 910 1320 |
7/0.53mm (1.5mm2) | 2 5 10 20 30 | 13.7 17.8 25.2 33.8 40.4 | 250 400 800 1400 2040 |
Note: Due to the different structure of instrument cables, this page only lists departmental specifications, you can always kontakt oss about customized instrument cables.
Instrumentation Cable Installation and Wiring Tips
- —Under the eaves. Standard cables can be used only if the cable is not exposed to direct sunlight or extreme heat, and conduit is recommended. Do not use cables without UV protection in direct sunlight.
- —On the outer wall. Avoid direct sunlight on the wall and man-made damage. Heating cables are exposed to high temperatures in metal conduit or trunking, and many polymeric materials experience reduced service life at these temperatures.
- —In pipes (plastic or metal). If in pipes, pay attention to the damage to plastic pipes and the heat conduction of metal pipes. Once mechanical damage occurs, fiber optic cables are expensive to repair, requiring at least two terminations at each discontinuity point.
- —Suspended applications/luftkabler. Consider cable sag and stress. The cable is exposed to direct sunlight or not.
- —Directly laying in the underground cable trench, this environment is the smallest control range. The installation of the cable trench should be checked regularly for dryness or dampness. If the shield of the control cable needs to be grounded, the appropriate standards must be followed.
VERI Transportation with Professional Service
VERI Cable har flere måter å beskytte kablene dine på, med solid og profesjonell fraktemballasje og omfattende forsikring. Før frakt, our cables are packaged in wooden reels and corrugated box coils. Under transport, for å beskytte kabelendene mot fuktighet, vi forsegler dem med BOPP selvklebende tape og ikke-hygroskopisk.
Hvis det er kvalitetsproblemer som skadet emballasje og produktoverflateskader på stedet når varene mottas, hvis varene er bekreftet å være sanne, varene stemmer ikke overens med bestillingen, og kvalitetsproblemene kunden oppdager under installasjonen, legging og bruksprosessen er bekreftet å være kvalitetsproblemene til selve produktet, Dersom leveransen ikke er i samsvar med kontraktskravene, vennligst kontakt vårt firma direkte.