Armored Electric Cable

armored electric cable supplier

Armored Electric Cable does not have a specific model number, it refers to a large category in the classification of cables, Kabel VERI can be customized according to the customer to provide a variety of parameters and specifications for the appropriate armored cable products. VERI armored power cables are suitable for transmitting and distributing power in transmission and distribution systems from 0.6kv~35kv or lower voltages. It also prevents rodents from chewing through the armor which can cause power transmission problems. In addition to the above purposes, the addition of an armor layer to the cable enhances the mechanical protection properties such as tensile and compressive strength, I extends the service life.

Zapytanie teraz

Armored Cable Types and Sizes

Flexible Copper Oil Resistant PVC Armored Control Cable
Zapytanie teraz

Flexible Copper Oil Resistant PVC Armored Control Cable

The Armored Control Cable can be produced according to the standard GB9330-1988, IEC, Z, and BS, and the factory can also manufacture the cables by other standards.

Napięcie znamionowe: 450/750V
Dyrygent: Copper wire /tinned-copper wire, Class1, Class2, Class5
Izolacja: PVC /PE /XLPE
Cabling: multicore stranded
Shield(if required): Copper tape or CWS or Al-plastic tape with drain wire
Inner sheath (applicable if there is an armor layer): PVC/PE
Armour layer: Drut stalowy ocynkowany / Steel tape
Outer sheath: PVC/PE/LSHF
Other characteristics: Oil resistant, Flame retardant, Anti-corrosion, UV, itp.

Product Parameter Specification

Typ
Name
Section Area(mm2)
NIE. of Core
Application Site
KVV
Przewodnik miedziany,PVC Insulated and Sheathed Control Cable
0.75 1.0 1.5 2.5
2-16
Permanent installation indoors,in cable ditches or pipes
4 6
2-14
10
2-10
KVVP
Przewodnik miedziany,PVC Insulated and Sheathed,Braiding Shielded Control Cable
0.75 1.0 1.5 2.5
2-61
Permanent installation indoors,in cable ditches or pipes where shielding is required
4 6
2-14
10
2-10
KVVP2
Przewodnik miedziany,PVC Insulated and Sheathed,Copper-tape Screened Control Cable
0.75 1.0 1.5 2.5
4-10
Permanent installation indoors,in cable ditches or pipes where shielding is required
4 6
7-61
10
4-10
KVV22
Przewodnik miedziany, PVC Insulated and Sheathed, Steel tape Armored Control Cable
0.75 1.0 1.5 2.5
7-61
Permanent installation indoors,in cable ditches,Be able to withstand stronger external mechanical force

Aplikacja

Armored Control Cable is suitable for the connection of control equipment and monitor instruments and is also used as power and connecting cables in mechanical engineering for tooling machinery, control units, production lines, transportation equipment, conveyor and assembly lines as well as in plant construction under the circumstance that the rated voltage is up to 450/750V AC.

Stainless Steel Tube Flexible Armored Fiber Optic Cable
Zapytanie teraz

STA Tube Flexible Armored Fiber Optic Cable

Steel armored cable fiber optic can be divided into indoor armored fiber optic cables and outdoor armored fiber optic cables according to the application of fiber optic cables. Ponadto, armored fiber optic cable can also be divided into interlocking armored fiber optic cable and corrugated armored fiber optic cable according to the different types of metal armor. Indoor armored fiber optic cable: indoor armored fiber optic cable includes single-layer armored and double-layer armored fiber optic cable.

Fiber Type: G.652D, G.657A1 or G.657A2 single mode fiber and OM1, OM2, OM3, OM4 mutimode fiber.

Cechy: 1. Mini diameter SUS spring tube reinforced ensures good crush resistance. 2. Kevlar strengthened provides good tensile strength. 3. LSZH Outer jacket complies with UL, RoHS.

Aplikacja:

1. Applied to the patch cord of the optical terminal.

2. Indoor outdoor for FTTH and optical distribution, connection between optical cable and communication equipment room.

MC Armored 12/2 Flexible Metal Clad Cable
Zapytanie teraz

MC Armored 12/2 Flexible Metal Clad Cable

VERI Type MC Armored Cable can be used for feeder and branch circuit lines as specified in NEC. The insulation wire core of type MC cable is XHHW-2, it can be used in dry and wet locations with the highest working temperature not exceeding 90. The rated voltage of type MC cable is 600V. The cable consists of three or four XLPE insulated phase cores plus one bare ground conductor. Interlocked aluminum armor tape is applied over all the cables. A PVC jacket is optional. MC cable with PVC jacket provides extra durability. long-term reliability and installation security.

Dyrygent: AA-8030 aluminum alloy conductors
Izolacja: Polietylen usieciowany(XLPE) izolacja
Zbroja: Interlock aluminum tape armor
Zakres temperatur: Temperature of 90 C in wet and dry locations
Środowiskowy: Free of harmful heavy metals in compliance with RoHS
Napięcie znamionowe:600Volt

Cable Data Sheet:

Conductor Size( AWG,Kcmil)

Nominal insulation Thickness

Nominalna średnica całkowita

Approx.Weight

inch

miles

lbs/1000ft

6-6-6-6

45

819

283

4-4-4-6

45

906

350

2-2-2-6

45

1016

446

Standard: ASTM-B,B-801 and B-836, UL standard 44 for XHHW-2, UL Standard 1569, RoHS environmental conductive requirement

Specifications:

The AA-8000 aluminum alloy conductor is applied in Type MC cable.
Its insulated core complies with the requirement of Type XHHW-2 in UL44.
Insulation material is cross-linked polyethylene(XLPE) with characteristics property, which can meet the FT2 level combustion test requirement.
MC cable, USA, UL & NEC standard, armored cable, metal-clad cable, AC cable, BX cable, TECK cable, interlocked armored cable.

Distinguished by Armor Layer Structure

Steel Tape Armored Cable supply

STA Steel Tape Armored Cable

Dyrygent: Soft Bare / Tinned Copper
Materiał izolacyjny: PVC/PE/XLPE/RUBBER
Rozmiar: 1.25mm² ~325mm²
Numer rdzenia: 1 C~60C
Armoured Layer: Steel Wire
Jacket Metarial: PCV, PE, LSZH, RUBBER
Napięcie znamionowe: 600V/1000V
Standard: IEC, licencjat, ON, OEM, ODM
Aplikacja: Suitable for places that are prone to aging, harsh environments and acidic corrosion such as those containing chemicals.

Get A Free Quotation
Steel wire armored cable supplier

SWA Steel Wire Armored Cable

Dyrygent: Soft Bare / Tinned Copper
Rozmiar: 1.25mm² ~325mm²
Numer rdzenia: 1 C~60C
Materiał izolacyjny: PVC/PE/XLPE/RUBBER
Armoured Layer: Steel Wire
Materiał kurtki: PCV, PE, LSZH, RUBBER
Napięcie znamionowe: 600V/1000V
Standard: IEC/BS/JIS/OEM/ODM
Aplikacja: Suitable for places that are prone to aging, harsh environments and acidic corrosion such as those containing chemicals.

Get A Free Quotation

AWA ATA Aluminum Tape Aluminum Wire Armored Cable

AWA ATA Aluminum Tape Aluminum Wire Armored Cable

Dyrygent: Soft Bare/Tinned Copper
Rozmiar: 1.25mm² ~325mm²
Core Nubmer: 1 C~60C
Izolacja: PVC/PE/XLPE/RUBBER
Armoured Layer: Aluminium Wire/Aluminium Tape
Materiał kurtki: PCV, PE, LSZH, RUBBER
Napięcie znamionowe: 600V/1000V
Standard: IEC, licencjat, ON, OEM, ODM
Aplikacja: Suitable for places that are prone to aging, harsh environments and acidic corrosion such as those containing chemicals.

Get A Free Quotation

Advantages of Armored Electrical Cables

Compared with the characteristics of unarmored and mineral insulated cables, armored cables have the following advantages:

Characteristics

Armored Cables

Nieopancerzony Cables

MICC Cables

Mechanical damage resistance

High

Low

Extremely high

Corrosion resistance

Medium

Low

High

Weights

Medium

Light

Heavy

Obowiązujący scenariuszs

Underground, tereny przemysłowe

Indoor equipment connection

High-temperature, high-pressure places

Notatka: You need to choose the right cable for your needs, not blindly choose for the best.

Często zadawane pytania

How long does armored electrical cable last?

VERI cable production of various types of armored cable life can be up to 20 lata -40 lata, under the premise of ensuring the quality of production, armored cable life is mainly affected by the use of the environment and operating conditions. Na przykład, when laid outdoors, long-term exposure to extreme weather may shorten the life. Or long-term overload or over-temperature operation may lead to cable insulation aging, reducing cable life.

Jaka jest minimalna wielkość zamówienia?

Typowo, Minimalna wielkość zamówienia dla wszystkich kabli obsługiwanych przez VERI Cables wynosi 500 metrów, ze względu na wagę niektórych kabli, nawet w małych ilościach, może być bardzo wysoka i może prowadzić do zakłóceń w kosztach transportu. Dlatego zalecamy zakup lokalny w przypadku zamówień na kable o wartości mniejszej niż 500 metrów. Nadal możesz przesłać nam zapytanie dotyczące kabla wysokiego napięcia.

Jak mam się z tobą komunikować?

On VERI Cable's website, możesz skontaktować się z nami za pośrednictwem pola zapytania, e-mail (sales@vericable.com), WhatsApp (+86 17303836349). Obsługujemy również wideokonferencje z naszymi klientami i zapraszamy ich do odwiedzenia nas.

Informacje o serwisie posprzedażnym firmy VERI Cable

Wysyłka zamówienia kabla ZMS
Shipboard transportation of cables

Pierwszy, Zobowiązanie do jakości produktu:

  1. Istnieją zapisy dotyczące jakości i dane testowe dotyczące produkcji i testowania wszystkich produkty kablowe.
  2. Do kontroli działania produktu, serdecznie zapraszamy użytkowników do osobistego sprawdzenia całego procesu i działania produktu. Po potwierdzeniu, że produkt jest kwalifikowany, zostanie zapakowany i wysłany.

Drugi, zobowiązanie dotyczące ceny produktu:

  1. W celu zapewnienia wysokiej niezawodności produktu, wybór materiału systemu odbywa się z produktów krajowych lub wysokiej jakości.
  2. Na tych samych warunkach konkurencji, nasza firma szczerze zapewni Państwu przystępną cenę bez zmniejszania parametrów technicznych produktu lub zmiany komponentów produktu.
  3. Zobowiązanie dotyczące czasu dostawy:

Trzeci, Czas dostawy produktu:

W miarę możliwości zgodnie z wymaganiami użytkownika, jeśli istnieją specjalne wymagania, które należy spełnić z wyprzedzeniem, nasza firma może specjalnie zorganizować produkcję i montaż, i staramy się spełniać potrzeby użytkowników.

Czwarty, zaangażowanie w obsługę posprzedażną:

  1. Zasada usługi: szybko, decydujący, dokładny, przemyślany i dokładny.
  2. Cele usługi: jakość usług, aby zdobyć satysfakcję klienta.
  3. Wydajność usług: Jeżeli sprzęt ulegnie awarii w okresie gwarancyjnym lub poza nim, po powiadomieniu dostawcy, the maintenance personnel can reach the site and start maintenance within 24 godziny.
  4. Service principle: The warranty period of cable products is twelve months. During the warranty period, the supplier will repair and replace the parts damaged due to quality reasons for free. If the parts are damaged outside the warranty period, the provided accessories will only charge the cost the cost of equipment damage caused by human factors of the buyer, and the accessories repaired or provided by the supplier are calculated at cost.

    Prosimy o przesłanie zapytania w poniższym formularzu.

    E-mail*:

    Nazwa*:

    Kraj*:

    TEL*:

    Darmowa wycena*: