Tradução


+86-371-67829333


Notícias

Qual é a diferença entre cabo blindado e cabo não blindado?

Cabos blindados e não blindados são ambos tipos de cabos de alimentação, e são os dois tipos de cabos de alimentação mais comumente usados. Cabos de energia all consist of conductor, isolamento do condutor, e camada protetora externa.

O difference between armored cables and unarmored cables lies in the presence or absence of an armor layer. Comparado com cabos não blindados, armored cables have an additional metal protective structure, offering stronger resistance to pressure, impacto, rodents, and tensile strength. They can be used in direct burial, ar livre, e ambientes industriais agressivos.

Based on years of overseas project experience, ZMS Cables has found that most project failures are not due to product quality issues, but rather to incorrect application scenarios and incompatible armor configurations, leading to rework. This article will provide an in-depth analysis of these two types of cables to help customers mitigate risks.

Cabo blindado VS cabo não blindado

What is armored cable?

What is unarmored cable?

Cabo blindado is a reinforced power cable with an additional metal armor layer between the cable insulation layer and the outer sheath. Common armor materials are steel tape and steel wire; aluminum tape armor can also be used depending on requirements.

The overall structure of armored cable, from the inside out, includes:

conductor → insulation layer → inner lining layer → metal armor layer → outer sheath.

The metal armor layer does not change the cable’s conductivity but can resist external forces such as compression, impacto, tensão, and animal bites, while also providing a certain degree of electromagnetic shielding.

Armored cables are mainly used in scenarios such as direct underground burial, outdoor cable trays, industrial plants, road crossings, and deep-buried pipelines.

What is unarmored cable?

Unarmored cable is basic power cable without any metallic armor protection layer.

The standard structure of unarmored cable only includes:

conductor → insulation layer → outer sheath.

Unarmored cable features: Estrutura simples, cabo flexível, pequeno raio de flexão, instalação fácil, and lower cost.

Unarmored cables lack mechanical protection and cannot withstand compression, impacto, or strong tension. Unarmored cables are only suitable for low-risk environments such as fully protected indoor conduits, enclosed cable trays, and internal equipment wiring.

armored cable VS unarmored cable

Diferença entre cabo blindado e cabo não blindado

Tipo Cabo blindado Cabo não blindado
Estrutura Metallic armor layer No armor layer
Mechanical Protection Pressure/impact/tensile resistant, anti-rodent/termite No protection, easily damaged
Instalação Subterrâneo, Enterro direto, trincheiras, locais industriais Interior, cable trays, conduítes, protected areas
Características Hard, heavy Soft, flexível, light
Lifespan Highly durable, long-lasting Ages outdoors easily
Custo Mais alto More economical

Common types of armored cables

Armor Type Abbr. Estrutura Key Applications
Fita de aço blindada Sta Double steel tape, high crush resistance Flat direct burial, municipal grids, standard ducts
Fine Steel Wire Armored SWA Stranded fine wires, alta resistência à tração River/mountain crossing, aerial suspension, deep wells
Coarse Steel Wire Armored CWA Coarse wire reinforced, ultra-high tensile strength Long-span suspension, mineração, heavy duty
Aluminum Tape Armored Ata Leve, resistente à corrosão, non-magnetic High-corrosion environments, AC magnetic fields

Armored Cables vs. Unarmored Cables: How to Choose?

Based on overseas engineering standards and practical field experience, ZMS Cables summarizes a simple selection logic:

Scenarios for Choosing Armored Cables:

  • Cables need to be directly buried underground;
  • Outdoor open-air, field, or factory grounds;
  • Sites with risks of mechanical crushing, digging, or impact;
  • Forest areas and rural areas with wildlife bites;
  • Crossing rivers, torres, or high-altitude suspension requiring tensile strength.

Scenarios for Choosing Unarmored Cables:

  • Entirely indoor installation, using enclosed conduits and sealed cable trays;
  • Internal wiring within equipment;
  • Construction environment free from external damage;
  • Limited project budget with comprehensive protective measures throughout.
Comparison of cable laying scenarios

Accurate Cable Quotes: Information You Need to Provide as a Customer

Many overseas inquiries suffer from repeated communication and low efficiency, primarily due to incomplete parameters.

We have compiled essential parameters for quick quotes, which engineers can directly refer to when submitting:

  1. Execution Standard: CEI / Bobagem / GB and other project-specified standards
  2. Classificação de tensão: 0.6/1kV, 10kV, 35kV, etc..
  3. Number of Cores and Cross-section: Por exemplo, 3×95+1×50mm²…
  4. Armoring Requirements: Steel tape armor / Armadura de arame de aço / Sem armadura
  5. Material da bainha: PVC / Educação Física / LSZH flame retardant and fire resistant…
  6. Usage Environment: Interior / Enterro Direto / Ar livre / Corrosive / Extremely Cold
  7. Purchase Quantity, Delivery Location, and Delivery Time Requirements

Frequently Asked Questions (Perguntas frequentes)

Q1: Can armored cables be used as shielded cables?

  • Armored cables can provide basic electromagnetic shielding, but they cannot replace dedicated shielded cables.
  • For high-frequency, precision equipment, and high-voltage metering applications, professionally shielded cables are still required.

Q2: Can unarmored cables be temporarily laid outdoors?

  • It is not recommended. Short term exposure will accelerate sheath aging, rachaduras, and water ingress, and will likely lead to insulation failure.

Q3: Must armored cables be grounded?

  • Sim. Engineering specifications require reliable grounding at both ends of the armor layer to avoid induced voltage and leakage safety hazards.

Q4: Is there a difference in current carrying capacity between the two types of cables?

  • Under the same cross-section and material, the current carrying capacity is basically the same. The armor structure does not affect conductivity, only improves mechanical protection.

Why Choose ZMS Armored/Unarmored Cables?

As a cable manufacturer that has long served overseas contractors and EPC contractors, we understand that overseas projects have higher requirements for stability and compliance.

Cabo ZMS manufactures its full range of armored and unarmored power cables in strict accordance with international standards such as IEC, Bobagem, e GB. The materials used in conductors, isolamento, armadura, and sheaths are fully controlled, eliminating potential engineering risks such as recycled materials and falsely labeled cross-sections.

Além disso, we can provide a complete set of factory test reports, qualification documents, and third-party certifications. We also support customized designs for flame-retardant, resistente ao fogo, resistente ao frio, and corrosion-resistant cables for special environments, matching the needs of various power distribution projects.

Conclusão

There is no absolute superiority or inferiority between armored and unarmored cables; it’s all about suitability for the specific application scenario. Unarmored cables are preferred for controlled indoor environments, while armored cables are essential for outdoor direct burial and harsh conditions to ensure long-term stable operation.

If you are unsure whether you require armored construction or how to choose models and standards, please send your project parameters and construction environment. ZMS Cable technical team will provide free professional selection solution and accurate quotation.

Cabo zms f

Recent Posts

O que é cabo isolado aéreo? Estrutura e aplicações do cabo ABC

À medida que os países impõem requisitos cada vez mais rigorosos à segurança da rede eléctrica, the problems of traditional bare

1 day ago

Qual é a diferença entre o cabo de alimentação offshore e o cabo de alimentação normal?

Os cabos de energia usados ​​em ambientes offshore enfrentam desafios que os cabos terrestres comuns raramente encontram. Exposure

3 days ago

O que você deve entender sobre cabos aéreos antes de seu projeto de energia?

Se você olhar para cima nas cidades, cidades e paisagens rurais remotas, overhead cables stretch out

5 days ago

Qual é a diferença entre XLPE e cabo de PVC, e qual você deve escolher?

Ao escolher um cabo elétrico, the insulation material matters just as much as the conductor.

1 week ago

Como escolher o cabo submarino certo: Um guia de compras

Escolher o cabo submarino certo é uma decisão importante para parques eólicos offshore, projetos de energia na ilha,…

2 weeks ago

Que tipo de cabo é usado para data centers? Soluções completas de cabos IDC

Os data centers são a espinha dorsal da economia digital. But behind every server rack and

2 weeks ago