AAC AAAC ACSR CABLE

AAC AAAC ACSR

VERI ڪيبل, according to different uses, produces a variety of مٿي ڪيبل. Including AAC, AAAC, ACSR, ABC cableaerial bundled cable, ۽ ايئن. Our range of overhead lines generally contains aluminum conductors or aluminum alloy conductors to meet all customer needs. We specialize in providing excellent overhead lines for transmission, distribution, and power network industries. And other cable products such as voltage cables, submarine cables, fiber cables, special cables, ۽ ايئن. So please contact us with your requirements. Also, we will reply to you the detailed information that you want.

Types of VERI AAC AAAC ACSR

All Aluminum Conductor—AAC

المونيم Alloy ڪنڊڪٽر is the main component of the overhead power line. Its function is to transmit current and electric power. These bare conductors are suitable for low, وچولي, and high-voltage overhead lines. AAC is widely used in urban areas, where the span is usually short. But the conductivity requirements are high.

معيار&حوالا:ASTM—B 230, ASTM—B 231, DIN48201, BS215 (Or producing by the standard of the customer’s country)

  • Phase conductors: round stood or compacted 1350-H19 aluminum or copper conductor, AAAC, ACSR
  • Neutral or messenger conductor: round stood or compacted 6201 aluminum alloy or AAC, ACSR
  • Street lighting conductor: round stood or compacted aluminum conductor
  • موصليت: LDPE, HDPE, ايڪس ايل پي اي, پي وي سي

Manufacturing Standards

Conductor Size

Code Words

Class

Required Construction

Mass

Rated Strength

Cmils or AWG

mm²

نه. of Wires

Diameter of Wire

Per 1000ft, lb

Per km, kg

kips

kn

In.

ايم ايم

3500000

1773

Bluebonnet

اي

127

0.1660

4.22

3345

4977

58.7

261

3000000

1520

Trillium

اي

127

0.1537

3.90

2840

4226

50.3

223

2750000

1393

Bitterroot

اي

91

0.1738

4.42

2602

3872

46.1

205

2500000

1267

Lupine

اي

91

0.1657

4.21

2365

3519

41.9

186

2250000

1140

Sagebrush

اي

91

0.1572

3.99

2128

3166

37.7

167

2000000

1013

Cowslip

اي

91

0.1482

3.77

1873

2787

34.2

153

1750000

886.7

Jessamine

AA

61

0.1694

4.30

1641

2442

29.7

132

1590000

805.7

Coreopsis

AA

61

0.1614

4.10

1489

2216

27.0

120

1510500

765.4

Gladiolus

AA,اي

61

0.1574

4.00

1417

2108

25.6

114

1431000

725.1

Carnation

AA,اي

61

0.1532

3.89

1342

1997

24.3

108

1351000

694.8

Columbine

AA,اي

61

0.1488

3.78

1266

1884

23.4

104

APPLICATION

All aluminum conductors belong to bare conductors, which mainly play the role of transmitting electrical energy. Based on different voltages, the wire cross-sectional area is also different. AAC cable is commonly used for general distribution lines with a small force and small span. But it is not allowed to contact with trees.

هاڻي انڪوائري

All Aluminum Alloy Conductor—AAAC

ڪنڊڪٽر: Hard-Drawn 1350-H19 Aluminum Wires, Minimum Purity 99.45%.
Reinforcement: Galvanized Steel Wires (Zinc-Coated)
اڏاوت (Aluminum/Steel): 6/1, 7/1, 8/1, 12/7, 16/19, 24/7, 26/7, 30/7, 30/19, 36/1, 45/7, 54/7, 54/19, 72/7, 76/19, 84/19
Cross-Sectional Area: 6~4/0 awg, 80~2312 mcm (80~211.3 mcm for Standard High-Strength Conductor).
Galvanization: Class A, B or C
Grease Corrosion Protection: Available upon Request

Specifications
AAAC bare conductor meets the following ASTM specifications :
B-398 Aluminum Alloy 6201-T81 Wire for Electrical Purposes
B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.

The Part of AAAC-ASTM-B399 Technical Data:

Stranding

Diameter of conductor

Linear mass

Rated strength

D.C. resistance at 20℃

No./mm

ايم ايم

Kg/km

kgf

Ω/ڪلوميٽر

6

7/1.55

4.65

36.44

422

7/1.68

5.04

42.7

502

4

7/1.96

5.89

57.89

685

48.69(4)

7/2.12

6.35

67.56

799

2

7/2.47

7.42

92.14

1091

77.47(2)

7/2.67

8.02

107.50

1275

1/0

7/3.12

9.35

146.50

1733

123.3(1/0)

7/3. 37

10.11

171.00

2019

2/0

7/3.50

10.52

184.70

2090

155.4(2/0)

7/3.78

11.35

215.16

2447

3/0

7/3.93

11.79

232.70

2641

195.7 (3/0)

7/4.25

12.75

271.50

3079

4/0

7/4.42

13.26

293.70

3334

246.9 (4/0)

7/4.77

14.30

342.60

3885

Application:

Used as bare overhead conductor for primary and secondary distribution. The AAAC conductor is designed to get a better strength-to-weight ratio and offer improved electrical properties, excellent sag-tension characteristics, and superior corrosion resistance when compared with ACSR. As compared to a conventional ACSR conductor, the lighter weight, comparable strength & current carrying capacity, lower electrical losses, and superior corrosion resistance have given AAAC a wide acceptance in the distribution and medium & high voltage transmission lines.

هاڻي انڪوائري

Aluminum Conductor Steel Reinforced—ACSR

ACSR conductor has the advantages of simple structure, convenient erection and maintenance, low line cost, and large transmission capacity. And they are convenient for laying across special geographical conditions. Such as rivers and valleys, good electrical conductivity, and sufficient mechanical.

ڊيزائن
1 Aluminum conductor with increased breaking load, round stranded compressed (RM)
2 Core insulation (XPLE black, UV-resistant, not flame retardant); 2 تائين 4 cores of the equal cross-section are stranded together in left-hand lay, additionally 1 يا 2 cores of the reduced cross-section can be co-stranded.

معيار&حوالا:ASTM—B 230, ASTM—B 231, DIN48201, BS215 (Or producing by the standard of the customer’s country)

ACSR Technical Characteristics / U.S.A SizesASTM B232

Area

Stranding and diameter

Approximate overall diameter

المونيم

Steel

Total

المونيم

Steel

AWG or MCM

mm2

mm2

mm2

ايم ايم

ايم ايم

ايم ايم

8

8.34

1.39

9.73

6/1.33

1/1.33

3.99

6

13.29

2.19

15.48

6/1.68

1/1.68

5.04

4

21.16

3.55

24.71

6/2.12

1/2.12

6.36

4

21.16

5.35

26.50

7/1.96

1/2.61

6.53

3

26.69

4.45

31.14

6/2.38

1/2.38

7.14

2

33.61

5.61

39.22

6/2.67

1/2.67

8.01

2

33.61

8.52

42.13

7/2.47

1/3.30

8.24

1

42.39

7.10

49.49

6/3.00

1/3.00

9.00

0

53.48

8.90

62.38

6/3.37

1/3.37

10.11

2/0

67.42

11.23

78.65

6/3.78

1/3.78

11.34

3/0

85.03

14.19

99.22

6/4.25

1/4.25

12.75

4/0

107.23

17.87

125.10

6/4.77

1/4.77

14.31

Application of ACSR

1. The higher-strength ACSR conductors are widely used in power transmission lines with various voltage levels.
2. The higher-strength ACSR conductors are commonly used for river crossings, overhead earth wires, and installations involving extra-long spans.
3. The higher-strength ACSR conductors are also suitable for laying across rivers and valleys where special geographical features exist.

هاڻي انڪوائري

Excellent Service of VERI Cable

ايڪسپورٽ تجربو

هڪ پیشہ ور ڪيبل ٺاهيندڙ جي طور تي, اسان جي ڪيبل مصنوعات ماضي ۾ ڪيترن ئي ملڪن کي برآمد ڪيو ويو آهي 30 سال, آمريڪا سميت, ڪينيڊا, اسپين, UK, جرمني, فرانس, روس, گريسي, سعودي عرب, وغيره. انهن ملڪن ۾, اسان جي ڪيبل مصنوعات گراهڪن سان تمام مشهور آهن. ۽ هر سال, اسان جي سٺي معيار ۽ خدمت جي ڪري, اسان کي اسان جي گراهڪن کان تمام سٺو موٽ ملي ويندي.

ڪسٽمائيز ڪيبل سروس

اسان جي ڪسٽم خدمتن جي حد ۾ ڊيزائن شامل آهي, ماپ, ۽ سطح جو رنگ. ڪيترائي مشهور رنگ پڻ موجود آهن توهان کي چونڊڻ لاءِ. اسان پڻ اوور شيٿنگ ۾ ماهر آهيون, مثال طور, اسان ڪسٽم Polyethylene ٺاهي سگهون ٿا (پي اي) ۽ Polyurethane (PUR) توهان جي گهرجن مطابق. اسان توهان جي خيالن جي بنياد تي حل مهيا ڪري سگهون ٿا. مهرباني ڪري اسان سان رابطو ڪريو اسان کي پنهنجو خيال ڏيو.

سخت معيار جي چڪاس جي معيار

ويري ڪيبل پيش ڪري ٿو وسيع قسم جي پاور ڪيبلز جي بنياد تي رجحانات ۽ ذاتي ترجيحات. ۽ اسان هر قسم جي پاور ڪيبل فراهم ڪندا آهيون, ڪان وڌيڪ 100 سلسلو. پوءِ, ڪيبل جي معيار کي يقيني بڻائڻ لاء, اسان اسان جي پروڊڪٽس کي جانچڻ تي اصرار ڪندا آهيون هڪ دفعو ۾.

    مھرباني ڪري ھيٺ ڏنل فارم ۾ پنھنجي انڪوائري ڏيڻ لاء آزاد ٿيو.

    Email*:

    Name*:

    Country*:

    TEL*:

    Free Quote*: