Instrumentation Cable

Instrumentation cables manufactured by VERI Cable are certified to GB, IEC, BS, ASTM, ISO900, ISO14000, ISO14001, ISO18000, BS, CE, IEC, NFC, ASTM and DIN.

To date, VERI Cable has produced instrumentation cables for use in a variety of applications and types, including fully automated production, power equipment, tunnel lighting, or laying into cable trenches. The length of the cables sold reaches више од 50,000 meters, and their resistance to moisture and corrosion is widely appreciated.

Инкуири Нов

Types of Instrumentation Cables

Инкуири Нов

CU/XLPE Insulated Instrumentation Cable---0.6/1KV

Construction
Conductor: Annealed or tinned copper
Pairing: Two or three insulated conductors uniformly twisted together with a lay not exceeding 100 mm
Binder Tape: PETP transparent tape
Standard
IEC 60502, BS 5308, GB 9330

450/750v 0.5mm2 0.75mm2 1mm2 CU/XLPE insulated instrumentation cable

Shielding

Braid

Jacket/Insulation

PVC/XLPE/PE

Rated Voltage

600V

Size

0.5mm2-1000mm2 customizable

Type

Low Voltage/Medium Voltage/High Voltage

Certificate

ISO, CCC, CE, VDE

Conductor Type

flexible

Sheath

PVC Sheath

Sheath Color

Black or blue

Advantages:
Fire prevention, anti-impact, anti-rat, anti-mosquito, anti-radiation
Low working temperature
Strong overload resistance
Long service life, high safety, explosion-proof, corrosion resistance
High mechanical strength

Typically used in industrial process manufacturing plants for communications, data, and voice transmission of signals and services, and also for the interconnection of electrical equipment and instruments, usually in the oil industry.

Copper Tape Screened Twisted Pair Instrument Cable

Individual Screen Armored Instrumentation Cable application:
Instrumentation cable Individual and overall Screened Steel Wire Armored/ SWA Pairs are used in data processing and process control. Suitable for fixed installations in damp locations and open spaces. The electrostatic screen protects against outer interference fields.
1. Design: LSZH (Low Smoke Zero Halogen) Instrumentation cable consisting of bare copper conductors, black & white, twisted pairs or black, white & red twisted triples with a continuous number sequence.
2. Voltage Rating: Rated Voltage Max. 300V a.c; Nominal Voltage A.C/D. C 110/150V, Test Voltage In process spark test – 4500V and AC withstand
voltage test – 1500V, TECHNICAL DATA 0.5mm 1.5mm
3. Operating Temperature: Minimum continuous operating temperature -25°C,75°C, 90°C, Minimum short circuit temperature 160°C (for 5 sec)

Conductor Material

Copper/copper aluminum tinned copper wire aluminum alloy

Insulation Material

PVC/XLPE

Shielding

Foil

Jacket

PVC

Color

all kinds of color is available

Standard

IEC BS ASTM DIN GB9330-1998

Sectional area

0.75 mm2 – 10 mm2

armored

steel tape steel wire

Inner Sheath

LSZH (Low Smoke Zero Halogen) Sheath

Outer Sheath

LSZH (Low Smoke Zero Halogen) Sheath is flame retardant, conforms to IEC60332-3-22, halogen-free, conforms to IEC60754-1, low smoke emissions, conforms to IEC61034-1-2

Conductor sizes

0.5 mm² solid, 1.0 mm² solid, 0.5 mm² flexible, 0.75 mm² flexible or 1.5mm²stranded

Collective screen

24 µm aluminum / PETP tape over tinned copper drain wire, 0.5 mm²

Maximum Capacitance:
Conductor to Conductor 145pF/m 200pF/m, Conductor to Screen 240pF/m 300pF/m, Maximum Conductor Resistance @ 20 C 38.4Ω/km 13.8Ω/km,
Insulation Resistance @ 20 C 40MΩ/km 140MΩ/km, Cross Talk Attentuation Between Pairs @ 1kHz 300Ω 150Ω
Inductance @ 1kHz 1.00mH/km 0.95mH/km, L/R Ratio @ 1kHz 13.7µH/Ω 36.5µH/Ω
Bending Radius:
The following minimum bending radius should be observed to ensure operating reliability
unarmoured: 9 x cable outer diameter (during installation) 6 x cable outer diameter (after installation)
Armoured: 18 x cable outer diameter (during installation) 12 x cable outer diameter (after installation)

Underwater Instrumentation Flat Shaft Electrical Cable

This product can be used as an underwater communication cable. It can be either a single network cable structure a coaxial cable structure, a network cable plus multicore power cable, or a coaxial cable plus multicore control cable structure. The network cable is more than Category 5 or Category 6, and the video cable is commonly used as 75-3/75-5, итд. This product can also be used as an underwater telephone line. When using it, you can choose 2 pairs to use as video recording lines, and you can choose any pair to use as a telephone line or as a communication cable. It is simple to use and convenient to maintain.

Characteristics of Underwater Network Cable:
It is resistant to underwater pressure, seawater corrosion, underwater low temperature, oil, cold, corrosion, UV, abrasion, flame retardant, and bending. It applies to the rapid movement and installation of instruments and equipment in the underwater field.

Conductor

multi strand super fine stranded oxygen free copper wire

Insulation Material

high-densitywaterproof material

Shielding

tinned copper wire fabric

Jacket

seawater resistant polyurethane

Color

core wires are distinguished by different colors

Network cable type

CAT5E/CAT6/CA6A

tensile strength

100/300/500KGcustomized

Rated voltage

300/300V

Collective screen

24 µm aluminium / PETP tape over tinned copper drain wire, 0.5 mm²

Water depth

100M/200m/500m, итд

Temperature range of underwater network cable:
Fixed installation – 40 ℃ to+85 ℃
Mobile installation: – 30 ℃ to+85 ℃

Bending radius of zero buoyancy steel wire mesh:
Fixed installation: 5 × Cable outer diameter (D)
Mobile installation: When the strokeis<10m, the bending radius is 7.5 × D When the stroke is ≥ 10m, the bending radius is 10 × D

Selection Tip: Selection of Instrumentation Cables in the Petrochemical Industry

Instrumentation cables for the petrochemical industry

The petrochemical industry, as one of the large industrial fields, has a harsh working environment involving temperature, pressure, corrosiveness and other extreme conditions, which puts higher requirements on the selection and design of instrumentation cables.

Select from VERI Instrumentation Cables:

— Cable Material:

In the petrochemical industry, cables made of corrosion-resistant, high-temperature-resistant, fire-retardant and flame-retardant materials are the first choice. PVC is suitable for general processes, and polyethylene ПЕ is the first choice for oil-, acid- and alkali-resistant. VERI cables can be customized to be made of high-temperature materials, such as FEP, PFA, or silicone rubber.

— Cable Specifications and Performance:

Conductor StructureLogarithms

Maximum Nominal Outside Diameter

(mm)

Nominal Weight (kg/km)
1/0.8mm
(0.5mm 2)
2
5
10
20
30
9.7
12.9
17.7
22.9
27.3
100
190
320
570
820
16/0.2mm
(0.5mm2)
2
5
10
20
30
11.4
14.6
20.5
26.7
31.7
160
250
480
780
1100
24/0.2mm
(0.75mm2)
2
5
10
20
30
12.2
15.7
21.8
28.5
33.7
190
270
550
960
1320
1/1.13mm
(1.0mm2)
2
5
10
20
30
12.2
15.6
22.0
29.2
34.8
190
270
480
910
1320
7/0.53mm
(1.5mm2)
2
5
10
20
30
13.7
17.8
25.2
33.8
40.4
250
400
800
1400
2040

Note: Due to the different structure of instrument cables, this page only lists departmental specifications, you can always contact us about customized instrument cables.

Instrumentation Cable Installation and Wiring Tips

  1. —Under the eaves. Standard cables can be used only if the cable is not exposed to direct sunlight or extreme heat, and conduit is recommended. Do not use cables without UV protection in direct sunlight.
  2. —On the outer wall. Avoid direct sunlight on the wall and man-made damage. Heating cables are exposed to high temperatures in metal conduit or trunking, and many polymeric materials experience reduced service life at these temperatures.
  3. —In pipes (plastic or metal). If in pipes, pay attention to the damage to plastic pipes and the heat conduction of metal pipes. Once mechanical damage occurs, fiber optic cables are expensive to repair, requiring at least two terminations at each discontinuity point.
  4. —Suspended applications/overhead cables. Consider cable sag and stress. The cable is exposed to direct sunlight or not.
  5. —Directly laying in the underground cable trench, this environment is the smallest control range. The installation of the cable trench should be checked regularly for dryness or dampness. If the shield of the control cable needs to be grounded, the appropriate standards must be followed.

VERI Transportation with Professional Service

ЗМС поруџбина каблова

ВЕРИ Цабле има више начина за заштиту ваших каблова, са чврстим и професионалним паковањем за отпрему и свеобухватним осигурањем. Пре слања, our cables are packaged in wooden reels and corrugated box coils. Током транспорта, за заштиту крајева кабла од влаге, залепимо их БОПП самолепљивом траком и нехигроскопно.

ЗМС кабловске наруџбе упаковане у прилагодљиве бачве

Ако постоје проблеми са квалитетом као што су оштећена амбалажа и оштећење површине производа на лицу места када је роба примљена, ако се потврди да је роба истинита, роба не одговара поруџбини, и проблеми са квалитетом које је купац пронашао током инсталације, процес полагања и употребе потврђени су као проблеми квалитета самог производа, Ако испорука није у складу са захтевима уговора, молим те контактирајте нашу компанију директно.

    Слободно дајте свој упит у форму испод.

    е-пошта*:

    име*:

    земља*:

    ТЕЛ*:

    Бесплатна понуда*: