Airport Lighting Cable
Airport lighting cable, also known as a Type C airport cable, is a specific type of industrial cable used in airports to sustain runways.
VERI kabel is a professional exporter of airfield lighting cables and special cables in China. Suppliers and airport cable manufacturers for a wide range of high-quality airport lighting cables to suit all kinds of applications. It is commonly the case that airfield lighting cables are required quickly and in small quantities. We use the latest technology available in our industry for the manufacturing of all airport lighting cables, which are now lighter, more durable, and more flexible. Our airfield lighting cables are manufactured to international standards with FAA, AC 150/5345-7E, and ICEA standards. The conductors of airport lighting cables are copper and aluminum.
Types of VERI Airport Lighting Cable
Faa-L-824 5kv 1X6mm2 8AWGAirport Ground Lighting Cable
VERI Airport Lighting Cable 5 kV is used for power transmission from the power generator to the lighting and guiding light. In lighting system of the airport, is buried directly in the ground or installed in a duct buried in the ground, rated voltage of 5 kV.
Dirigent: Stranded bare or tinned copper.
Inner Semi-Conductor: Extruded semi-conducting compound.
Isolering: XLPE.
Outer Semi-Conductor: Semi-conducting tape or extruded.
Shield: Copper or brass tape(s). Tinned copper wire braid can be offered upon request.
Slida: PVC. PE/XLPE can be offered upon request.
Dimensions and Weight
Konstruktion | Inga. of Strand | Nominal Insulation Thickness | Nominal Overall Diameter | Nominal Weight |
Inga. x mm^2/ AWG | – | mm | mm | kg/km |
1×6mm^2 | 7/19 | 2.3 | 11.0 | 180 |
1×8 | 7/19 | 2.3 | 14.3 | 298 |
1×6 | 7/19 | 2.3 | 15.4 | 366 |
1×4 | 7/19 | 2.3 | 17.0 | 513 |
TECHNICAL CHARACTERISTICS
Märkspänning: 5 kV
Test voltage: 18 kV AC (5 minutes)
The maximum conductor temperature for normal operation is 90ºC
The maximum conductor temperature for short-circuit (5s maximum duration) is 250ºC
Continuous working current up to 20 A
Minimum bending radius: 9 x D (D: cable diameter)
APPLIED STANDARDS
– FAA L-824 Type C – ANSI/NEMA WC 74/ICEA S-93-639-2012
Airport Ground Lighting Cables with shielded
DATA airport lighting cables can be found in terminals and in airports all over the world. These cables are suitable for operation at 600v or 5kv in wet or dry locations. Conductors shall be annealed copper. The insulation layer of cables with different voltages is different.
Till exempel, the insulation layer of 600v cable should be a black cross-linked polyethylene insulation layer that is wear-resistant, moisture-proof and heat-resistant. The 5kv cable shall have a 20 mil extruded XLPE conductor shield. The voltage of 5kv cables should have cross-linked polyethylene that is abrasion, moisture, heat and track resistant.
STANDARDER&REFERENSER:IEC 60502, IEC 332-3, IEC 60228, FAA AC 1 50/5345-7E
- Ledarmaterial: Bare or tinned copper
- Typ av ledare: Stranded
- Isoleringsmaterial: Ethylene Propylene Rubber(EPR)
- Shield: Tinned copper tape
- Färg: Green/Blue/Red/Grey/Black or as your requirements
- Spänning: 5kv
ANSÖKAN
Specifically designed for airport security and airport systems, airport ground lighting cables illuminate runways during take-off and landing approaches. Dessa kablar are suitable for stationary applications such as taxiways, runways, navigation aids, and obstacle lighting. It can be installed in a conduit and directly buried.
5KV Airport Lighting Cable
Single conductor 5000-volt nonshielded power cables suitable for L-824 underground installation for lighting at airports per FAA L-824 Type C and AC 150/5345-53. Veri Cable offers a range of airports lighting cables from shield through to shielded, suitable for a range of primary and secondary circuits, available with PVC, Polyolefin, or HDPE sheathing. They are all XLPE insulated, providing a maximum operating temperature of 90 grader. They are supplied with a voltage of 5kv.
STANDARDER&REFERENSER:CEA S-96-659, NEMA WC71
- Ledarmaterial: Bare or tinned copper
- Typ av ledare: Stranded
- Isoleringsmaterial: Ethylene Propylene Rubber(EPR)
- Färg: Green/Blue/Red/Grey/Black or as your requirement
- Spänning: 5kv
ANSÖKAN
The type of unshielded airport lighting cable is primarily used for series lighting circuits for runways, control systems, and other multi-purpose installations. It can be used for direct burial, conduit, or raceway.
The above airfield ground lighting cables consist of standard supply cables covering a wide range of specific applications and environments. Our kabelprodukter have been widely used in many airport buildings and airport runways. For more information about airport lighting cables, please contact us freely.
The Feature of Airport Lighting Cable
Airport lightning cable is flexible, lättvikt, and fire-resistant in nature. The conductor can be of different materials of Aluminum/Copper. The airport lighting cables are semiconductive screened, which allows the cable to be safely operated continuously to the ground. In the cable industry, an insulator is a part that covers the conductor so that current cannot flow and cause any electrical failure. The insulator can be wire or any insulating material. PVC/XLPE insulation is responsible for a fire-resistant feature.
Airport lighting cables are built for usage in between the constant current source and the isolating transformers in the series lighting circuits. Particularly lighting sources such as runways, taxiways, navigational aids, and obstruction lighting. It is fitted for use in direct burial connections, pulled into metallic or non-metallic conduit.
Om VERI Cables kundservice
Första, Engagemang för produktkvalitet:
- Det finns kvalitetsregister och testdata för tillverkning och testning av alla kabelprodukter.
- För inspektion av produktens prestanda, vi uppmanar uppriktigt användare att inspektera hela processen och produktens prestanda personligen. Efter att produkten har bekräftats vara kvalificerad, det kommer att packas och skickas.
Andra, produktprisåtagandet:
- För att säkerställa produktens höga tillförlitlighet, materialvalet i systemet är gjort av inhemska eller högkvalitativa produkter.
- Under samma konkurrensvillkor, vårt företag kommer uppriktigt att ge dig till ett överkomligt pris utan att minska produktens tekniska prestanda eller ändra produktkomponenterna.
- Leveranstidsåtagande:
Tredje, Produktens leveranstid:
Så långt det är möjligt enligt användarens krav, om det finns särskilda krav som måste fyllas i i förväg, vårt företag kan speciellt organisera produktion och installation, och strävar efter att möta användarnas behov.
Fjärde, kundserviceåtagande:
- Serviceprincip: snabb, avgörande, exakt, genomtänkt och noggrann.
- Servicemål: servicekvalitet för att vinna kundnöjdhet.
- Serviceeffektivitet: Om utrustningen går sönder inom garantiperioden eller utanför garantiperioden, efter att leverantören underrättats, underhållspersonalen kan nå platsen och påbörja underhåll inom 24 timmar.
- Serviceprincip: Garantitiden för kabelprodukter är tolv månader. Under garantitiden, leverantören reparerar och ersätter de delar som skadats på grund av kvalitetsskäl gratis. Om delarna är skadade utanför garantitiden, de medföljande tillbehören kommer endast att debitera kostnaden för utrustningsskador orsakade av mänskliga faktorer hos köparen, och de tillbehör som repareras eller tillhandahålls av leverantören beräknas till självkostnadspris.