High Voltage Cables

High-voltage cables, according to different materials can be divided into aluminum high-voltage cables and copper-core cables. Due to complex environmental conditions and special requirements in certain areas, the use of copper-core cables is more reliable in terms of quality and safety. According to our production experience, the selection of cable type and cross-sectional area should refer to the surrounding environment, the corresponding laying method and the performance of electrical equipment.

Fråga nu

Typer av VERI högspänningskabel

Fråga nu

YJV22 3 Core HV Armored Steel Tape Kopparkabel

Isolerade PVC-mantlade strömkablar används för kraftöverföring och distributionssystem med märkspänningar på 0,6/1kv, 1.8/3kv, 3.6/6kv, 6/10kv, 8.7/10kv, 8.7/15kv, 12/20kv, 21/35kv, 26/35kv.

1. XLPE isolerad, PVC-mantlade strömkablar (YJV, YJLV) är lämpliga för inomhusbruk, tunnlar, rör, och begravd i jord (inte utsatt för mekanisk kraft)
2. XLPE isolerad, ståltejp bepansrade PVC-mantlade strömkablar (YJV22, YJLV22) är lämpliga för inomhusbruk, tunnel, rörgenomföring, och begravd i jord
3. XLPE isolerad, ståltråd bepansrade PVC-mantlade strömkablar (YJV32, 42, YJLV32, 42) är lämpliga för axlar, vatten, platser med fall, och tål yttre krafter.

The Minimum Bend Radius of the Cable

Punkt
Tre kärnor
Obepansrad
Armerad
Minsta böjradie för kabeln under installationen.
15D
12D
Minsta böjradie för kabeln nära kopplingsdosa och terminal
12D
10D
Notera: D är kabelns ytterdiameter

Storleksinformation

Tvärsnittsarea(mm²)
Isolerad tjocklek(mm)
Metallsköldtjocklek(mm)
Jackans tjocklek(mm)
AV(mm)
Vikt(kg/km)
3×25
4.5
30×0.10
2.4
44.8
2251.6
3×35
4.5
40×0.10
2.5
47.2
2655.9
3×50
4.5
40×0.10
2.6
50.4
3217.3
3×70
4.5
40×0.10
2.7
54.0
3957.2
3×95
4.5
40×0.10
2.8
57.7
4884.7
3×120
4.5
40×0.10
2.9
60.9
5754.2
3×150
4.5
40×0.10
3.0
64.5
6788.0
3×185
4.5
40×0.10
3.1
68.2
7961.6
3×240
4.5
40×0.10
3.3
73.5
9801.3
3×300
4.5
40×0.10
3.4
78.3
11725.3
3×400
4.5
40×0.10
3.7
85.8
14799.2

Produktens strukturfunktioner:

1. Har bra motstånd mot höga temperaturer: XLPE-isolering använder kemiska eller fysikaliska metoder för att ändra strukturen hos polyetenmolekyler till en tredimensionell nätverksstruktur. Den tredimensionella nätverksstrukturen har bra värmebeständighet och kan användas i Långtidsarbete vid hög temperatur på 90 grader Celsius, livslängden kan vara så lång som 40 år.
2. Den har bra isoleringsförmåga: polyeten behåller inte bara isoleringsförmågan hos tvärbunden polyeten utan har också en ytterligare förbättring av isoleringsmotståndet.
3. Höga mekaniska egenskaper: hårdhet, styvhet, slitstyrka, och slagtålighet har förbättrats
4. Kemisk beständighet: XLPE i sig har stark syra- och alkalibeständighet och oljebeständighet
5. Miljöskydd: Eftersom produkterna av tvärbunden polyetenförbränning är vatten och koldioxid, miljöföroreningarna är låga, och den uppfyller brandsäkerhetskraven.
6. Den maximala märktemperaturen för kabelledaren är 90°C, och den maximala temperaturen under kortslutningen (den längsta varaktigheten överstiger inte 5S) inte överstiger 250°C.

Fråga nu

HV aluminiumledare stålförstärkt kabel

Aluminiumledare, stålförstärkt luftkabel, används främst i kraftöverföringsledningar med hög spänning. Dess fördelar inkluderar hög mekanisk hållfasthet, god elektrisk ledningsförmåga, korrosionsbeständighet, ljusenhetsvolym, lätt erektion, motstånd mot hög temperatur, enkel struktur, bekväm installation, bra underhåll, och stor överföringskapacitet. Högspänningsstålkabeln från ACSR består av en solid eller tvinnad stålkärna omgiven av strängar av aluminium.

  • Dirigent: Aluminium
  • Gatubelysningsledare: Rundstående eller komprimerad aluminiumledare
  • Isolering: LDPE/HDPE/XLPE/PVC

STANDARDER&REFERENSER: GB/T12527/IEC60502/NFC 33-209/BS 7870/ANSI/ICEA S-76-474 AS/NZS 35601

HV ACSR-ledare enligt GOST 839-80

AvsnittAluminium delStåldelMin. Brytstyrka
Antal ledningarNom. tråddiameterAntal ledningarNom. tråddiameter
116/2.761.85 mm.11.85 mm.6,220 N.
225/4.262.30 mm.12.30 mm.9,296 N.
335/6.262.80 mm.12.80 mm.13,524 N.
450/8.063.20 mm.13.20 mm.17,112 N.
570/1163.80 mm.13.80 mm.24,130 N.
670/72182,20 mm.192.20 mm.96,862 N.
795/1664.50 mm.14.50 mm.33,369 N.
8120/19262.40 mm.71.85 mm.41,521 N.
9120/27302.20 mm.72.20 mm.49,465 N.
10150/19242.80 mm.71.85 mm.46,307 N.
11150/24262.70 mm.72.10 mm.52,279 N.
12150/34302.50 mm.72.50 mm.62,643 N.
13185/24243.15 mm.72.10 mm.58,075 N.
14185/29262.98 mm.72.30 mm.62,055 N.
15185/43302.80 mm.72.80 mm.77,767 N.
16205/27.0243.30 mm.72.20 mm.63,740 N.
17240/32243.60 mm.72.40 mm.75,050 N.
18240/39263.40 mm.72.65 mm.80,895 N.
19240/56303.20 mm.73.20 mm.98,253 N.
20300/39244.00 mm.72.65 mm.90,574 N.
21300/48263.80 mm.72.95 mm.100,623 N.
22300/204542.65 mm.372.65 mm.284,579 N.
23330/43.0542.80 mm.72.80 mm.103,784 N.
24400/18423.40 mm.71.85 mm.85,600 N.
25400/51543.05 mm.73.05 mm.120,481 N.
26400/64264.34 mm.73.40 mm.129,183 N.
27400/93304.15 mm.192.50 mm.173,715 N.
28500/27762.84 mm.72.20 mm.112,188 N.
29500/64543.40 mm.73.40 mm.148,257 N.
30600/72543.70 mm.192.20 mm.183,835 N.

ANSÖKAN

Den typ av dessa kablar som används i eldistributionsledningar som går över floder och dalar där speciella geografiska varelser finns. Ledaren för ACSR representerar den viktigaste komponenten i en luftledning eftersom de måste säkerställa ekonomisk och tillförlitlig överföring och bidra avsevärt till de totala linjekostnaderna.

Förläggning av VERI högspänningskablar

Besiktning före kabelläggning: om modellen och specifikationerna uppfyller kraven, isoleringen ska vara bra, utseendet ska vara komplett, och det ska inte finnas några spår av trauma.

En extra längd bör reserveras nära kabelanslutningen, och en reservlängd bör reserveras för den direkt nedgrävda kabeln i den vågformade läggningen. Avståndet mellan varje stödpunkt i kabeln ska vara enligt konstruktionen. När det inte finns några konstruktionsbestämmelser, det bör inte vara större än gummi kablar. Dessa plastkablar är horisontella 1M, vertikal 2M, och kablar upphängda på stålkablar som är horisontella 0,75M. Kabelns böjradie bör inte vara mindre än 10 gånger kabelns ytterdiameter (bepansrad eller obepansrad flerledad plastisolerad strömkabel).

Vid förläggning av kablar, kablarna ska dras ut från den övre änden av rullen, och undvik friktion och drag av ledningarna på fästet och marken. Kablarna ska inte korsas vid läggning, de ska vara snyggt ordnade, och fixade, och skyltar bör installeras. Det ska finnas fasta pålar i hörnen på de direkt nedgrävda kablarna. När kablar går in i kabelgravar, tunnlar, bebyggelse, och rör, in- och utgångar bör stängas. Klämmor och fixturer för AC enkellediga kablar bör inte ha en sluten magnetisk krets som består av järn.

Transport med professionell service

ZMS Cable Order Shipment

VERI Cable har flera sätt att skydda dina kablar, med robust och professionell fraktförpackning och heltäckande försäkring. Innan frakt, vår kablar är förpackade i trärullar och korrugerade lådspolar. Under transport, för att skydda kabeländarna från fukt, vi förseglar dem med BOPP självhäftande tejp och icke-hygroskopisk.

ZMS cable orders packed in customizable barrels

Om det finns kvalitetsproblem som skadad förpackning och produktyteskador på plats när varorna tas emot, om varorna bekräftas vara sanna, varorna stämmer inte överens med beställningen, och de kvalitetsproblem som kunden hittat under installationen, läggnings- och användningsprocessen bekräftas vara kvalitetsproblemen för själva produkten, Om leveransen inte är i enlighet med kontraktskraven, snälla du kontakta vårt företag direkt.

    Lämna gärna din förfrågan i formuläret nedan.

    E-post*:

    Namn*:

    Ditt land:

    TEL*:

    Free Quote*: