ABC(Aerial Bundled Conductor)Cable
VERI ABC Cable is extensively used for combining single-core or multiple single-core cables. And their specifications are 0.6/1kv or 6.5/35kv. Then ABC cables are widely used to temporarily distribute street lighting and secondary pole service.
As a professional mtengenezaji wa cable, our cable products are all of the best quality. Kama vile low voltage, macho ya nyuzi, airport lighting, na solar cables. And they have been exported to many countries every year—for example, Australia, Uhispania, Kenya, Rwanda, and Bangladesh. So we will deliver each order strictly according to the delivery time. And we ensure the smooth progress of the customer’s projects.
VERI Aerial Bundle Cable Types
Aluminum Conductor XLPE Low Voltage Aerial Bundled Cable 4x35mm
1. Voltage: 0.6/1KV.
2. Kondakta: Pure annealed copper or aluminum.
3. Uhamishaji joto: XLPE/PE/PVC.
4. Cores: 1 C, 2C, 3C, 4C.
5. Nominal Cross-section: 10mm2 to 400mm2.
6. Kawaida: GB/T 14049-2008, IEC 60502.
7. Max. Operating Temperature: XLPE/PE: 90 °C, PVC: 70 °C.
8. Aina: Cable ya ABC, JKTRYJ, JKLYJ,JKTRY, JKLY, JKLGYJ, JKLGY, JKLYJ/Q, JKLY/Q, JKLGYJ/Q, JKLGY/Q.
9. Ufungashaji: Wooden Drum or according to the customer requirement.
The cable can be of flame retardant, fire resistance, and other properties.
ABC – Aerial Bundled Cables, acc. BS (British Standard) 7870-5
number of cores x nominal cross-section | max. conductor-resistance | min. breaking load of conductor strand | current rating in the air | kipenyo cha nje | AL number | total weight |
mm² | Ohm/km | kN | A | ca. mm | kg/km | ca. kg/km |
1x 16 RM | 1,910 | 2,5 | 72 | 8,0 | 55 | 74 |
1x 25 RM | 1,200 | 4,0 | 107 | 9,0 | 72 | 106 |
1x 35 RM | 0,868 | 5,5 | 132 | 10,5 | 102 | 138 |
1x 50 RM | 0,641 | 8,0 | 165 | 11,8 | 145 | 182 |
1x 70 RM | 0,443 | 10,7 | 205 | 13,0 | 203 | 252 |
1x 95 RM | 0,320 | 13,7 | 240 | 15,4 | 276 | 333 |
1x 120 RM | 0,253 | 18,6 | 290 | 17,0 | 348 | 408 |
1x 150 RM | 0,206 | 23,2 | 334 | 19,0 | 435 | 502 |
1x 185 RM | 0,164 | 28,7 | 389 | 21,0 | 537 | 611 |
1x 240 RM | 0,125 | 37,2 | 467 | 24,0 | 696 | 801 |
2x 16 RM | 1,910 | 2,5 | 72 | 15,6 | 93 | 147 |
2x 25 RM | 1,200 | 4,0 | 107 | 18,0 | 145 | 208 |
2x 35 RM | 0,868 | 5,5 | 132 | 20,0 | 203 | 277 |
2x 50 RM | 0,641 | 8,0 | 165 | 23,5 | 290 | 361 |
2x 70 RM | 0,443 | 10,7 | 205 | 25,4 | 408 | 505 |
2x 95 RM | 0,320 | 13,7 | 240 | 30,3 | 551 | 666 |
2x 150 RM | 0,206 | 23,2 | 334 | 38,0 | 870 | 1004 |
4x 16 RM | 1,910 | 2,5 | 72 | 18,8 | 186 | 286 |
4x 25 RM | 1,200 | 4,0 | 107 | 21,2 | 290 | 430 |
4x 35 RM | 0,868 | 5,5 | 132 | 24,1 | 406 | 553 |
4x 50 RM | 0,641 | 8,0 | 165 | 27,8 | 580 | 746 |
4x 70 RM | 0,443 | 10,7 | 205 | 31,8 | 812 | 1.009 |
4x 95 RM | 0,320 | 13,7 | 240 | 37,8 | 1.102 | 1.332 |
4x 120 RM | 0,253 | 18,6 | 290 | 54,4 | 1.392 | 1.632 |
4x 50 + 1x 25 RM | 0,641/1,200 | 8,0/4,0 | 165/107 | 31,9 | 653 | 814 |
4x 50 + 1x 35 RM | 0,641/0,868 | 8,5/5,5 | 165/132 | 31,9 | 682 | 845 |
4x 70 + 1x 25 RM | 0,443/1,200 | 10,7/4,0 | 205/107 | 36,0 | 885 | 1.105 |
4x 70 + 2x 25 RM | 0,443/1,200 | 10,7/4,0 | 205/107 | 40,0 | 956 | 1.217 |
4x 95 + 1x 25 RM | 0,320/1,200 | 13,7/4,0 | 240/107 | 41,8 | 1.175 | 1.438 |
4x 95 + 2x 25 RM | 0,320/1,200 | 13,7/4,0 | 240/107 | 42,0 | 1.247 | 1.544 |
4×120 + 1x 25 RM | 0,253/1,200 | 18,6/4,0 | 290/107 | 59 | 1.464 | 2.05 |
Maombi
Used to supply power, usually from a pole-mounted transformer, to the user’s service head where connection to the service entrance. To be used at 600V or less phase to phase and at conductor temperatures not to exceed 75°C for polyethylene insulated or 90°C for cross-linked. Not suitable for direct burial.
VIWANGO&MAREJEO: IEC 60502 / AS / NZS 3599-1 viwango
Low Voltage PVC PE XLPE Insulated Aerial Bundled ABC Cable
Low Voltage 3×95+1×70+1×16 3×120+1×70+1×16 3×150+1×95+1×16 3×185+1×120+1×16 Aerial Bundled Conductor ABC Cables details:
- Kawaida: NFC 33-209.
- Phase/Lightning conductor: Stranded All Aluminum 1350; AAC.
- Phase conductor Insulation: XLPE.
- Neutral conductor: All aluminum alloy.
- Neutral/Lightning conductor insultation: XLPE.
- The Rated Voltage: 0.6/1KV,Test voltage : 4 kV AC
Product Standard
Nominal Cross Section | Minimum Breaking Load | Current Rating in Air | Nominal Overall Diameter | Total Weight | Kipenyo cha Nje |
mm2 | Kn | A | mm | kg/km | mm |
2*16RM | 1.190 | 2.5 | 72 | 147 | 15.6 |
2*25RM | 1.200 | 4.0 | 107 | 208 | 18 |
2*35RM | 0.868 | 5.5 | 132 | 277 | 20 |
2*50RM | 0.641 | 8.0 | 165 | 361 | 23.5 |
4*16RM | 1.190 | 2.5 | 72 | 286 | 18.8 |
4*25RM | 1.200 | 4.0 | 107 | 430 | 21.2 |
4*35RM | 0.868 | 5.5 | 132 | 553 | 24.1 |
4*50RM | 0.641 | 8.0 | 165 | 746 | 27.8 |
4*70RM | 0.443 | 10.7 | 205 | 1.009 | 31.8 |
4*95RM | 0.320 | 13.7 | 240 | 1.332 | 37.8 |
4*120RM | 0.253 | 18.6 | 290 | 1.632 | 54.4 |
4*35+1*35RM | 0.868/0.868 | 5.5/5.5 | 132/132 | 694 | 30 |
4*50+1*25RM | 0.641/1.200 | 8.0/4.0 | 165/107 | 814 | 31.9 |
4*50+1*35RM | 0.641/0.868 | 8.5/5.5 | 165/132 | 845 | 31.9 |
4*70+1*25RM | 0.443/1.200 | 10.7/4.0 | 205/107 | 1.105 | 36 |
4*70+2*35RM | 0.443/1.200 | 10.7/4.0 | 205/107 | 1.217 | 40 |
4*70+1*25RM | 0.443/0.868 | 10.7/5.5 | 205/132 | 1.15 | 36.2 |
4*70+2*25RM | 0.443/0.868 | 10.7/5.5 | 205/132 | 1.289 | 40.1 |
4*95+1*25RM | 0.320/1.200 | 13.7/4.0 | 240/107 | 1.438 | 41.8 |
4*95+1*35RM | 0.320/0.868 | 13.7/5.5 | 240/132 | 1.467 | 41.8 |
4*95+2*25RM | 0.320/1.200 | 13.7/4.0 | 240/107 | 1.544 | 42 |
Duplex / Triplex Service Drop Wire Aluminum Conductor
Duplex Service Drop Wire, its main composition is 1350-H19 aluminum with phase conductors concentrically twisted and PVC or XLPE for insulation. The neutral core is made of concentrically twisted AAC, ACSR, au 6201 aloi ya alumini. Mainly used for 120V overhead service applications. Such as street lighting, outdoor lighting, and building temporary services. The voltage between the phases is 600V and below. The conductor temperature of PVC insulated conductors does not exceed 75 °C, and the conductor temperature of XLPE insulated conductors does not exceed 90 °C.
DUPLEX SERVICE DROP CABLE phase conductors are concentrically stranded according to ASTM B 231. Covered with weather-resistant black polyethylene compound. Neutral conductors are concentrically stranded ACSR according to ASTM B 232.
Cable Parameter Specifications
Makondakta | bare neutral messenger | Phase | |
AAC | ACSR | ||
Duplex service drop | Pekingese,Collie, Dachshund, Spaniel, Doberman, Malemute | Setter,Shepherd,Eskimo, | AAC |
Triplex service drop | Haiotis,Patella,Fusus, Oyster,Clam,Murex, Purpura,Nassa, Nannynose | Paludina,Voluta,Whelk, Periwinkle, Cenia,Runcina, Triton, Zuzara, Cockle, Aega,Cavolinia,Clio, Sanddollar,Cuttlefish, Cerapus, Cowry | |
Quadruplex service drop | Cllydesdate,Pinto, Mustang, | Morochuca,Chola,Morgan,Hackney, |
Code word | AWG or kcmil | Bare Neutral Messenger | Phase Conductor | Weight kg/km | ||||||
ACSR | Rated Strength lbs. | AAC | Insul. Thick. mm | |||||||
Hapana. | Ndiyo. mm | Hapana. | Ndiyo. mm | Hapana. | Ndiyo. mm | |||||
Shepherd | 1*6AWG+1*6AWG | 1 | 1.68 | 6 | 1.68 | 1190 | 7 | 1.56 | 1.14 | 113 |
Service drop cable meets or exceeds the following specifications:
- ASTM B-230 Aluminum Wire,1350-H19 for Electrical Purposes.
- ASTM B-231 Aluminum Conductors, Concentric-Lay-Stranded.
- ASTM B-232 Aluminum Conductor, Concentric-Lay-Stranded, Coated Steel Reinforced(ACSR)
- ASTM B-399 Concentric-Lay-Stranded 6201-T81 Conductors
- ASTM B-901 Compressed Round Stranded Aluminum Conductors Using Single Input Wire.
Usafiri na Huduma ya Kitaalam
Hamisha Uzoefu
Kama mtengenezaji wa kitaalamu wa cable, bidhaa zetu cable wamekuwa nje kwa nchi nyingi katika siku za nyuma 30 miaka, ikiwemo Marekani, Kanada, Uhispania, Uingereza, Ujerumani, Ufaransa, Urusi, Ugiriki, Saudi Arabia, na kadhalika. Katika nchi hizi, bidhaa zetu cable ni maarufu sana kwa wateja. Na kila mwaka, kwa sababu ya ubora na huduma zetu, tungepokea maoni mazuri kutoka kwa wateja wetu.
Huduma ya Cable Iliyobinafsishwa
Aina zetu za huduma maalum ni pamoja na muundo, ukubwa, na rangi ya uso. Rangi nyingi maarufu pia zinapatikana kwako kuchagua. Sisi pia utaalam katika over-sheathing, kwa mfano, tunaweza kutengeneza Polyethilini ya kawaida (PE) na polyurethane (PUR) kulingana na mahitaji yako. Tunaweza kutoa suluhu kulingana na mawazo yako. Tafadhali wasiliana nasi ili utupe wazo lako.
Viwango Vikali vya Ukaguzi wa Ubora
VERI Cable offers a wide variety of power cables based on trends and personal preferences. Na tunatoa kila aina ya nyaya za umeme, zaidi ya 100 mfululizo. Kisha, ili kuhakikisha ubora wa nyaya, tunasisitiza kupima bidhaa zetu mara moja moja.