UNDERSEA POWER CABLE

VERI Cable, specializing in submarine power cables, is suitable for telecommunications or transmission between countries or regions. We manufacture high-quality submarine cables with different voltages. In addition to our standard marine cable range, we support designing some special cables for specific project applications. VERI submarine power cables are manufactured as VDE, IEC, and ICEA or according to customersdesign and standards. For more information about our solutions for cable products, please feel free to contact us.

Submarine Cable Type and Application

Inquiry Now

XLPE Insulated AC Medium Voltage Submarine Power Cable

These submarine power cables are used for power transmission to offshore islands, oil platforms, or cross-rivers and lakes. The laying of submarine cables does not require digging tunnels or supporting them with brackets, and low investment or fast construction.

  • Conductor: Copper conductor, circular stranded compacted, water blocked
  • Conductor Screening: Extruded semi-conductive compound
  • Insulation: XLPE
  • Insulation Screening: Extruded semi-conductive compound
  • Waterproof layer: semi-conductive waterproof tape
  • Screen: Copper tapes
  • Separator: Plastic foil
  • Core Sheath: PE
  • Fillers: Polypropylene filler
  • Separator: Binder tapes
  • Bedding Layer: Polypropylene strings
  • Armor: Galvanized steel wires
  • Serving: Hessian tapes, bituminous compound, polypropylene strings

Specification Size and Technical Data:

Core number

Nominal Section(mm²)

D.C.Resistance in 20 oC(Ω/km)

O.D.(mm)

Reference Weight(Kg/km)

CU

AL

Cu

Al

1 core

1.5

24

6.1

49.2

46.6

2.5

34

25

6.5

61.6

61.5

4

44

33

7.4

85.4

74.3

6

57

44

8.0

109

90.1

10

76

58

9.6

151

116

16

103

78

10.2

223

173

25

129

108

12.0

331

212

35

172

131

13.1

432

272

70

268

207

16.0

780

472

150

435

335

22.1

1609

821

185

493

380

24.2

1966

1028

240

585

451

26.9

2513

1265

2 core

1.5

802

624

33.5

4108

2.5

20

10.2

116

117

4

27

21

11.0

148

159

6

36

27

12.8

207

194

10

46

35

13.8

262

228

16

62

48

15.4

351

301

25

83

63

18.5

532

456

50

131

101

24.3

1017

573

70

164

127

22.4

1201

735

95

208

160

25.2

1615

956

STANDARDS&REFERENCES: IEC 60228, IEC 60502, IEC 60840, IEC 62067

Using Feature:

1. The long-time working temperature of the cable should not be higher than 70℃.
2. When the core is in short-circuit (max 5s) the temperature should not exceed 160℃.
a. For a single no-armored cable, it is not less than 20 times of outer diameter
b. For single-core armored cable, it is not less than 15 times of outer diameter
c. For multicore no-armored cable, it is not less than 15 times of outer diameter
d. For multicore armored cable, it is not less than 12 times of outer diameter

APPLICATION

The core of the submarine power cable is covered with a PE outer sheath. After the single steel armor, the cable is finally completed with an outer sheath. So it is mainly for all marine environmental conditions, such as muddy, dry, wet, or oily conditions meeting the requirements. The range of voltage is 6/10(12)kV,12/20(24)kV, 18/30(36)kV, and so on.

Inquiry Now

XLPE Insulated DC High-Voltage Submarine Cable

A high-voltage submarine cable is used for high-voltage power transmission. Most of the submarine power cables are on the seabed at a certain depth, and they are not damaging the natural environment, such as wind and waves. Human production activities have interfered with them. Therefore, the cables are safe and stable, with strong anti-interference ability and good confidentiality.

  • Conductor: Copper conductor, water blocked
  • Conductor Screening: Extruded semi-conductive compound
  • Insulation: XLPE
  • Insulation Screening: Extruded semi-conductive compound.
  • Separator: Swelling tape
  • Core Sheath1: Lead Sheath
  • Core Sheath2: PE sheath
  • Bedding: Bedding layer
  • Armour: Galvanized steel wires filled with bitumen compound
  • Serving: Polypropylene yarn

STANDARDS&REFERENCES:IEC 60228, IEC 60502, IEC 60840, IEC 62067

APPLICATION

As a high-voltage power transmission cable, it is major for carrying electric power below the surface of the water. The range of voltage is 127/220(245)kV, 160/275(300)kV, 200/345(362)kV, 230/400(420)kV, and so on.

Standards and Applications

STANDARDS: IEC 60502, IEC 62067

APPLICATIONS: This applies to a solidly earthed system with a power frequency of 50-60Hz and rated voltage from 1kV to 500kV. Mainly used for high-power electric power transmission between mainland and island, island and island, or mainland and platform; control signal transmission of smart grid and communication signal transmission.

Our Professional Services

Quality Certification
The products manufactured by VERI Cables comply with international standards such as GB, IEC, BS, NFC, ASTM, DIN, etc. Moreover, our technical team can provide cable customization services for your needs.

Customer Tracking
VERI provides free professional cable consulting services, one-stop project solution services, and fast product delivery solutions.

Professional Transportation
VERI Cablesinitial goal is to ensure fast and safe delivery of products while also providing the best packaging and transportation solutions to reduce customerstransportation costs greatly.

Cable Packaging
VERI cable packaging is supplied in wooden reels, corrugated boxes, and coils. The ends are sealed with BOPP self-adhesive tape and non-hygroscopic sealing caps to protect the cable ends from moisture. We can print the required logo on the outside of the drums with waterproof material as per the customer’s requirement.

    Please feel free to give your inquiry in the form below.

    Email(required)*:

    Your name(required):

    Your country:

    TEL*:

    Information*: