The Voltage Rating Coaxial Ground Cable

The voltage level of the coaxial grounding cable should be determined according to the induced potential of the cable line. According to the past design experience, the voltage level of the coaxial grounding cable is generally 10kV; the cross-section of the coaxial grounding cable should be strictly selected according to the grounding current of the cable line. Проте, in actual work, due to the lack of data and the complexity of calculation. The main models are VOV, YJOV, and YOY.

Scope of Use

High-voltage cables are designed according to single-loop, double-loop, or even more loops. If the length of a single cable is longer, the induced potential will be larger. It is best not to exceed 50v, тобто, the voltage of 50 volts without protection devices. But if there are protective devices, such as return lines, coaxial cables, тощо, it should not exceed 300v.

The coaxial grounding cable is generally used for the lead wire of the arrester and the grounding wire of the lightning protection, and the grounding box of the line sheath insulation protection device of the cross-linked cable is connected. Impedance, coaxial ground cables have low impedance characteristics for transients.

VOV (YOV YJOV) is generally used for cross-connection of high-voltage cables to reduce the induced potential of the metal sheath. The protection box used for the 110KV~220KV cross-linked cable line sheath insulation protection device is connected with the transposition box. It is used for ground connection in transmission and distribution lines, and connection in cross-connect boxes. The inner and outer conductors of the coaxial cable are connected reasonably and conveniently and are reliable in use.

Conditions of Use

1. The maximum allowable working temperature of the conductor: is 90℃.

2. The bending radius is not less than 20 помножити на зовнішній діаметр кабелю.

3. The ambient temperature should not be lower than 0℃ when laying the coaxial grounding power cable.

4. The power frequency rated voltage 8.7/10KV transmission and distribution line (110kv ~ 220KV) is grounded.

5. The connection wire between the metal sheath of the cable or the voltage limiter of the shielding layer shall meet the following requirements: перше, the connecting line should be the shortest, and coaxial cable should be used above 3m. друге, the insulation level of the connecting wire shall not be less than the insulation level of the outer sheath of the cable. Thirdly, the cross-section of the connecting line should meet the thermal stability requirements when the single-phase grounding fault current of the system passes through.

ZMS Cable F

Recent Posts

Яка мета мінеральних утеплених кабелів? Просто видобуток?

Коли люди чують термін, утеплений мінерал, many immediately think of harsh environments like

2 months ago

Легке навчання —— Встановлення кабелю ADSS Крок за кроком для початківців

У міру того, як телекомунікаційні мережі та системи електропередачі швидко зростають, the demand for reliable and cost-effective

3 months ago

Впоратися! Які промислові кабелі потрібні у великому нафтогазовому проекті?

У масштабних нафтогазових проектах, Промислові кабелі - це не просто аксесуари—they are the "nervous

3 months ago

Найповніші типи кабелів - приходьте і виберіть те, що вам потрібно!

У світі електричних зв’язків, кабельні вкладки—також відомий як кабельні вуха або кабельні клеми—є…

3 months ago

Яка різниця між H05RR-F & H05RN-F & H07RN-F в гумовому кабелі?

При виборі правого гумового кабелю для проекту електротехніки, it is critical to

3 months ago

Happy Chinese New Year! —— ZMS Cable

Dear partners and customers: January 29th, 2025 is the Chinese Lunar New YearSpring

5 months ago