Medium Voltage Cable
VERI cable manufacturers specialize in supplying medium voltage underground power cables. The standard medium voltage underground power transmission cables produced include single and three-core copper or aluminum conductor cables. It also includes PVC, XLPE, PE, EPR and LSZH sheathing, as well as steel and aluminum wire armoring that provides mechanical protection. The voltage range is from 3.6 kV to 35 kV.As one of the leading international cable suppliers, VERI Cable has an extensive inventory of productive and cables. Such as high voltage cables, medium voltage cables and low voltage cables. All are available for quick shipment.
Types of VERI Medium Voltage Cable
10kv AL Conductor XLPE NA2XY Medium Voltage Cable
The medium voltage power cable can be used for laying indoors and outdoors. It can bear certain traction during installation. But not external mechanical forces. Laying single-core cables in magnetic ducts is not allowed. VERI medium voltage cable design based on the major national or international standards includes VDE, IEC, and ICEA. Or according to customers’ design and standards, we can support the customized cable product.
Dirijyor: Cu / Al / Al Alloy
Izolyatsiya materiallari: PVX / XLPE
Number of Cores: 1–5 Cores
Kurtka: PVX / PE / LSZH
Armour Type: STA / SWA
Sertifikatlash: ISO9001 / ISO14001 / OHSAS18001 / CCC
Model Number: VV, VV22, VV32, YJV, YJV22, YJV32
Hajmi: 2.5~630mm2
Type | Name | Usage |
VV | PVC insulated PVC sheathed power cable | Can be laid at indoor, tunnel, and tube. The cable cannot undertake mechanisms outside of force |
VLV | ||
VY | PVC insulated and PE sheathed power cable | Can be laid indoors, in tunnel tubes, and seriously polluted places. Cable cannot undertake mechanisms outside of force |
VLY | ||
VV22 | PVC insulated steel belt armored and PVC sheathed power cable | Can be laid indoors, in tunnel tubes, and mining wells. The cable cannot undertake mechanisms outside of force |
VLV22 | ||
VV23 | PVC insulated steel belt armored and PE sheathed power cable | Can be laid at indoor, tunnel tube mining wells, and seriously polluted places. The cable cannot undertake mechanisms outside of force |
VLV23 | ||
VV32 | PVC insulated fine steel wire armored PVC sheathed power cable | Can be laid at indoor, underground, and mining wells. Cable can undertake mechanism outside of force |
VLV32 | ||
VV33 | The PVC-insulated fine steel wire armored PE sheathed power cable | Can be laid indoors, or underground. The cable can undertake mechanisms outside of force |
VLV33 | ||
VV42 | PVC insulated thick steel wire armored PVC sheathed power cable | Can be laid indoors, underground, or mining well. The cable can undertake mechanisms outside the force |
VLV42 | ||
VV43 | The PVC-insulated fine steel wire armored PE sheathed power cable | Can be laid indoors, underground, in mining wells, and in places to are polluted. Cable can undertake mechanism outside force |
STANDARTLAR&ADABIYOTLAR: IEC60502-2, BS7870-4, BS7870-7, BS7870-8
3-35kV CU/XLPE/PVC/SWA/ Medium Voltage Cable
This model of medium voltage power cable is used as the main transmission cable to carry electricity in deep water, including power distribution and other important power transmission lines. Now you can get a quote for medium voltage cable from us.
Underwater medium voltage cable makes full use of the feature that optical and electrical signals do not interfere with each other. For intricate lines, it provides a solid base of protection and saves resources – Medium Voltage Cables for Power Distribution Networks.VERI Medium Voltage Cables are easy to operate and are not restricted by different standards when laying.
Part Number | Cross Section | To'planish | Approx Weight | Approx Overall Diameter | Gland Size | Single Cleat | Nom. Max. DC-resist conductor 20° C | Current rating laid direct |
(mm²) | (mm) | KG/KM | (mm) | (mm) | (Ohm/km) | (Amp) | ||
11KVPVC3X16 | 3 x 16 | 7/1.70 | 3440 | 44.3 | 40 | 1.8 | 1.15 | 119 |
11KVPVC3X25 | 3 x 25 | 7/2.14 | 4060 | 48.5 | 50 | 2 | 0.727 | 152 |
11KVPVC3X35 | 3 x 35 | 7/2.52 | 4495 | 50.5 | 50 | R9 | 0.524 | 181 |
11KVPVC3X50 | 3 x 50 | 19/1.78 | 5115 | 53 | 63s | R9 | 0.387 | 213 |
11KVPVC3X70 | 3 x 70 | 19/2.14 | 6035 | 56.8 | 63s | R10 | 0.268 | 260 |
11KVPVC3X95 | 3 x 95 | 19/2.52 | 7180 | 61.3 | 63 | R10 | 0.193 | 309 |
11KVPVC3X120 | 3 x 120 | 37/2.03 | 8280 | 65.1 | 75s | R11 | 0.153 | 349 |
11KVPVC3X150 | 3 x 150 | 37/2.25 | 9325 | 66.8 | 75s | R11 | 0.124 | 390 |
11KVPVC3X185 | 3 x 185 | 37/2.52 | 10740 | 72.3 | 75 | R12 | 0.0991 | 436 |
11KVPVC3X240 | 3 x 240 | 61/2.52 | 13820 | 79.3 | 90 | R14 | 0.0754 | 499 |
11KVPVC3X300 | 3 x 300 | 61/2.85 | 16120 | 84.2 | 90 | R15 | 0.0754 | 553 |
11KVPVC3X400 | 3 x 400 | 61/3.20 | 19350 | 92.4 | R15 | 0.047 | 619 |
- Minimum installation temperature: 0°C ;
- Maximum installation temperature: +60°C;
- Installation type: Outdoor – Direct burial;
- Minimum operating temperature:-15°C Maximum operating temperature:90°C;
- Short-circuit max. conductor temperature: 250°C;
- Flame retardant: BS EN 60332
XLPE Insulated Single Core MV N2XSY Cable
N2XSY is a single-core copper conductor XLPE-insulated cable with PVC over sheath, which forms an essential part of VERI Cables’ international medium voltage cable portfolio. It is a cable suitable for indoor and outdoor static installation, directly in the ground or in cable ducts, as part of power distribution networks, transformer stations, switching blocks, and power plants, including in the renewable energy sector. The N2XSY is self-extinguishing and flame retardant to VDE 0482-332-1-2 and IEC 60332-1.
Some of the characteristics of this cable, such as the flexibility of the conductors, facilitate the installation of N2XSY, even on challenging lines and in difficult conditions. It can be operated and installed at ambient temperatures from -5°C to +70°C.
N2XSY XLPE PVC – 6/10 (12)KV CABLE | N2XSY XLPE PVC – 12/20 (24)KV CABLE | N2XSY XLPE PVC – 18/30 (36)KV CABLE | |
VOLTAGE | 6/10 (12)kV | 12/20 (24)kV | |
CONDUCTOR | Sinf 2 Stranded Copper | ||
INNER SEMI-CONDUCTIVE LAYER | Semi-Conductive Material | ||
INSULATION | XLPE (Cross-Linked Polyethylene) | ||
OUTER SEMI-CONDUCTIVE LAYER | Semi-Conductive Material | ||
SCREEN | Copper Wires | ||
OUTER SHEATH | PVX (Polyvinyl Chloride) |
Advantages:
Cross-linked polyethylene insulated power cable not only has excellent electrical properties, mechanical properties, heat aging properties, environmental stress resistance, and chemical corrosion resistance but also has the advantages of simple structure, foydalanish oson, not limited by laying drop, long-term working temperature (90 degrees), large transmission capacity, va hokazo. Cross-linked polyethylene insulated power cable products flame retardant, nonflame retardant full series of crosslinked polyethylene insulated power cables.
A Perfect Partnership with VERI
JKLYYJY 24KV 1*185 Outside Diameter (mm): 29.8
Jami: 100km
240mm x 3 core Cu XLPE PVC SWA PVC (FR) 6.35/11kV to SABS 1339 Cable
Jami: 16500m
VERI kabellari’ medium voltage power products and accessories have been well received by our friends around the world, and we continue to work hard on this path. You can rest assured that VERI products are of high quality and certified, never short of quality, and delivered on time.
Transportation with ZMS Professional Service
VERI Cable has multiple ways to protect your cables, with sturdy and professional shipping packaging and comprehensive insurance. Before shipping, our cables are packaged in wooden reels and corrugated box coils. During transportation, to protect the cable ends from moisture, we seal them with BOPP self-adhesive tape and non-hygroscopic.
If there are quality problems such as damaged packaging and product surface damage on the spot when the goods are received, if the goods are confirmed to be true, the goods do not match the order, and the quality problems found by the customer during the installation, laying and use process are confirmed to be the quality problems of the product itself, If the delivery is not in accordance with the contract requirements, please contact our company directly.