Hochspannungskabel
High-voltage cables, according to different materials can be divided into aluminum high-voltage cables and copper-core cables. Due to complex environmental conditions and special requirements in certain areas, the use of copper-core cables is more reliable in terms of quality and safety. According to our production experience, the selection of cable type and cross-sectional area should refer to the surrounding environment, the corresponding laying method and the performance of electrical equipment.
Arten von VERI-Hochspannungskabeln
YJV22 3 Kern-HV-gepanzertes Stahlband-Kupferkabel
Isolierte PVC-ummantelte Stromkabel werden für Energieübertragungs- und -verteilungssysteme mit Nennspannungen von 0,6/1 kV verwendet, 1.8/3kv, 3.6/6kv, 6/10kv, 8.7/10kv, 8.7/15kv, 12/20kv, 21/35kv, 26/35kv.
1. XLPE isoliert, PVC-ummantelte Stromkabel (YJV, YJLV) sind für den Innenbereich geeignet, Tunnel, Rohre, und im Boden vergraben (keiner mechanischen Kraft ausgesetzt)
2. XLPE isoliert, Stahlbandarmierte PVC-ummantelte Stromkabel (YJV22, YJLV22) sind für den Innenbereich geeignet, Tunnel, Rohrdurchdringung, und im Boden vergraben
3. XLPE isoliert, Stahldrahtgepanzerte PVC-ummantelte Stromkabel (YJV32, 42, YJLV32, 42) sind für Wellen geeignet, Wasser, Orte mit Tropfen, und kann äußeren Kräften standhalten.
The Minimum Bend Radius of the Cable
Artikel | Dreikernig | |
Ungepanzert | Gepanzert | |
Mindestbiegeradius des Kabels bei der Installation. | 15D | 12D |
Der minimale Biegeradius des Kabels in der Nähe des Anschlusskastens und der Klemme | 12D | 10D |
Notiz: D ist der Außendurchmesser des Kabels |
Größeninformation
Querschnittsfläche(mm²) | Isolierte Dicke(mm) | Dicke der Metallabschirmung(mm) | Manteldicke(mm) | AUS(mm) | Gewicht(kg/km) |
3×25 | 4.5 | 30×0.10 | 2.4 | 44.8 | 2251.6 |
3×35 | 4.5 | 40×0.10 | 2.5 | 47.2 | 2655.9 |
3×50 | 4.5 | 40×0.10 | 2.6 | 50.4 | 3217.3 |
3×70 | 4.5 | 40×0.10 | 2.7 | 54.0 | 3957.2 |
3×95 | 4.5 | 40×0.10 | 2.8 | 57.7 | 4884.7 |
3×120 | 4.5 | 40×0.10 | 2.9 | 60.9 | 5754.2 |
3×150 | 4.5 | 40×0.10 | 3.0 | 64.5 | 6788.0 |
3×185 | 4.5 | 40×0.10 | 3.1 | 68.2 | 7961.6 |
3×240 | 4.5 | 40×0.10 | 3.3 | 73.5 | 9801.3 |
3×300 | 4.5 | 40×0.10 | 3.4 | 78.3 | 11725.3 |
3×400 | 4.5 | 40×0.10 | 3.7 | 85.8 | 14799.2 |
Produktstrukturmerkmale:
1. Hat eine gute Hochtemperaturbeständigkeit: XLPE-Isolierung nutzt chemische oder physikalische Methoden, um die Struktur von Polyethylenmolekülen in eine dreidimensionale Netzwerkstruktur umzuwandeln. Die dreidimensionale Netzwerkstruktur weist eine gute Hitzebeständigkeit auf und kann bei Langzeitarbeiten bei hohen Temperaturen eingesetzt werden 90 Grad Celsius, Die Lebensdauer kann so lang sein wie 40 Jahre.
2. Es hat eine gute Isolationsleistung: Polyethylen behält nicht nur die Isolationsleistung von vernetztem Polyethylen bei, sondern weist auch eine weitere Verbesserung des Isolationswiderstands auf.
3. Hohe mechanische Eigenschaften: Härte, Steifheit, Verschleißfestigkeit, und Schlagfestigkeit wurden verbessert
4. Chemische Resistenz: XLPE selbst weist eine starke Säure- und Alkalibeständigkeit sowie Ölbeständigkeit auf
5. Umweltschutz: Denn die Produkte der Verbrennung von vernetztem Polyethylen sind Wasser und Kohlendioxid, die Umweltbelastung ist gering, und es erfüllt die Brandschutzanforderungen.
6. Die maximale Nenntemperatur des Kabelleiters beträgt 90 °C, und die maximale Temperatur während des Kurzschlusses (Die längste Dauer überschreitet nicht 5S) 250°C nicht überschreitet.
HV-Aluminiumleiter, stahlverstärktes Kabel
Aluminiumleiter, stahlverstärktes Oberleitungskabel, wird hauptsächlich in Stromübertragungsleitungen mit Hochspannung eingesetzt. Zu seinen Vorteilen gehört die hohe mechanische Festigkeit, gute elektrische Leitfähigkeit, Korrosionsbeständigkeit, Lautstärke der Lichteinheit, leichte Erektion, Hochtemperaturbeständigkeit, einfache Struktur, bequeme Installation, gute Wartung, und große Übertragungskapazität. Das Hochspannungsstahlkabel von ACSR besteht aus einem massiven oder verseilten Stahlkern, der von Aluminiumsträngen umgeben ist.
- Dirigent: Aluminium
- Straßenbeleuchtungsleiter: Rundstabiger oder verdichteter Aluminiumleiter
- Isolierung: LDPE/HDPE/XLPE/PVC
STANDARDS&VERWEISE: GB/T12527/IEC60502/NFC 33-209/BS 7870/ANSI/ICEA S-76-474 AS/NZS 35601
HV-ACSR-Leiter gemäß GOST 839-80
Abschnitt | Aluminiumteil | Stahlteil | Mindest. Bruchfestigkeit | |||
---|---|---|---|---|---|---|
Anzahl der Drähte | Nom. Kabeldurchmesser | Anzahl der Drähte | Nom. Kabeldurchmesser | |||
1 | 16/2.7 | 6 | 1.85 mm. | 1 | 1.85 mm. | 6,220 N. |
2 | 25/4.2 | 6 | 2.30 mm. | 1 | 2.30 mm. | 9,296 N. |
3 | 35/6.2 | 6 | 2.80 mm. | 1 | 2.80 mm. | 13,524 N. |
4 | 50/8.0 | 6 | 3.20 mm. | 1 | 3.20 mm. | 17,112 N. |
5 | 70/11 | 6 | 3.80 mm. | 1 | 3.80 mm. | 24,130 N. |
6 | 70/72 | 18 | 2,20 mm. | 19 | 2.20 mm. | 96,862 N. |
7 | 95/16 | 6 | 4.50 mm. | 1 | 4.50 mm. | 33,369 N. |
8 | 120/19 | 26 | 2.40 mm. | 7 | 1.85 mm. | 41,521 N. |
9 | 120/27 | 30 | 2.20 mm. | 7 | 2.20 mm. | 49,465 N. |
10 | 150/19 | 24 | 2.80 mm. | 7 | 1.85 mm. | 46,307 N. |
11 | 150/24 | 26 | 2.70 mm. | 7 | 2.10 mm. | 52,279 N. |
12 | 150/34 | 30 | 2.50 mm. | 7 | 2.50 mm. | 62,643 N. |
13 | 185/24 | 24 | 3.15 mm. | 7 | 2.10 mm. | 58,075 N. |
14 | 185/29 | 26 | 2.98 mm. | 7 | 2.30 mm. | 62,055 N. |
15 | 185/43 | 30 | 2.80 mm. | 7 | 2.80 mm. | 77,767 N. |
16 | 205/27.0 | 24 | 3.30 mm. | 7 | 2.20 mm. | 63,740 N. |
17 | 240/32 | 24 | 3.60 mm. | 7 | 2.40 mm. | 75,050 N. |
18 | 240/39 | 26 | 3.40 mm. | 7 | 2.65 mm. | 80,895 N. |
19 | 240/56 | 30 | 3.20 mm. | 7 | 3.20 mm. | 98,253 N. |
20 | 300/39 | 24 | 4.00 mm. | 7 | 2.65 mm. | 90,574 N. |
21 | 300/48 | 26 | 3.80 mm. | 7 | 2.95 mm. | 100,623 N. |
22 | 300/204 | 54 | 2.65 mm. | 37 | 2.65 mm. | 284,579 N. |
23 | 330/43.0 | 54 | 2.80 mm. | 7 | 2.80 mm. | 103,784 N. |
24 | 400/18 | 42 | 3.40 mm. | 7 | 1.85 mm. | 85,600 N. |
25 | 400/51 | 54 | 3.05 mm. | 7 | 3.05 mm. | 120,481 N. |
26 | 400/64 | 26 | 4.34 mm. | 7 | 3.40 mm. | 129,183 N. |
27 | 400/93 | 30 | 4.15 mm. | 19 | 2.50 mm. | 173,715 N. |
28 | 500/27 | 76 | 2.84 mm. | 7 | 2.20 mm. | 112,188 N. |
29 | 500/64 | 54 | 3.40 mm. | 7 | 3.40 mm. | 148,257 N. |
30 | 600/72 | 54 | 3.70 mm. | 19 | 2.20 mm. | 183,835 N. |
ANWENDUNG
Der Typ dieser Kabel wird in Stromverteilungsleitungen verwendet, die über Flüsse und Täler verlaufen, wo besondere geografische Gegebenheiten vorkommen. Der Leiter eines ACSR stellt die wichtigste Komponente eines dar Freileitung denn sie müssen eine wirtschaftliche und zuverlässige Übertragung gewährleisten und tragen erheblich zu den Gesamtleitungskosten bei.
Verlegung von VERI-Hochspannungskabeln
Inspektion vor der Kabelverlegung: ob das Modell und die Spezifikationen den Anforderungen entsprechen, Die Isolierung sollte gut sein, Das Erscheinungsbild sollte vollständig sein, und es sollte keine Spuren eines Traumas geben.
In der Nähe des Kabelanschlusses sollte eine freie Länge reserviert werden, und bei der wellenförmigen Verlegung sollte eine freie Länge für das direkt erdverlegte Kabel reserviert werden. Der Abstand zwischen den einzelnen Drehpunkten des Kabels muss den Angaben in der Konstruktion entsprechen. Wenn es keine Gestaltungsvorschriften gibt, es sollte nicht größer sein als Gummi Kabel. Diese Kunststoffkabel sind horizontal 1 m lang, vertikal 2M, und an Stahlseilen aufgehängte Kabel, die sind horizontal 0,75M. Der Biegeradius des Kabels sollte nicht kleiner sein als 10 mal dem Außendurchmesser des Kabels (gepanzertes oder ungepanzertes mehradriges, kunststoffisoliertes Stromkabel).
Beim Verlegen der Kabel, Die Kabel sollten am oberen Ende der Trommel herausgezogen werden, und vermeiden Sie Reibung und Widerstand der Drähte an der Halterung und am Boden. Beim Verlegen sollten die Kabel nicht gekreuzt werden, sie sollten ordentlich angeordnet sein, und behoben, und Schilder sollten angebracht werden. An den Ecken der direkt erdverlegten Kabel sollten feste Pfähle angebracht sein. Wenn Kabel in Kabelgräben eindringen, Tunnel, Gebäude, und Rohre, Die Ein- und Ausgänge sollten geschlossen sein. Klemmen und Vorrichtungen für AC-Einleiterkabel Es darf kein geschlossener Magnetkreis aus Eisen vorhanden sein.
Transport mit professionellem Service
VERI Cable bietet mehrere Möglichkeiten, Ihre Kabel zu schützen, mit stabiler und professioneller Versandverpackung und umfassender Versicherung. Vor dem Versand, unser Kabel werden in Holzrollen und Wellpappspulen verpackt. Während des Transports, um die Kabelenden vor Feuchtigkeit zu schützen, Wir versiegeln sie mit BOPP-Selbstklebeband und sind nicht hygroskopisch.
Bei Qualitätsmängeln wie beschädigter Verpackung und Beschädigung der Produktoberfläche direkt beim Wareneingang, wenn die Ware als wahr bestätigt wird, Die Ware entspricht nicht der Bestellung, und die vom Kunden während der Installation festgestellten Qualitätsprobleme, Verlege- und Nutzungsprozess werden als Qualitätsprobleme des Produkts selbst bestätigt, Wenn die Lieferung nicht vertragsgemäß erfolgt, Bitte kontaktieren sie unser unternehmen direkt.