Self Regulating Heating Cable
Self Regulating Heating Cable provides precise, energy-efficient temperature control for applications ranging from residential frost protection to industrial pipe heating.VERI Cables designs and manufactures self-regulating heating cables that utilize advanced polymer core technology designed to automatically regulate output power to ensure consistent performance while saving energy. We can customize the right cable for your project solution, get a free quote.
Popular Models of Self-Regulating Heating Cables
Self-Regulating Heat Cable with Aluminum Magnesium Insulation
The self-controlling electric heating belt is composed of a conductive core belt with “PTC” characteristics and an insulating sheath covered, which can automatically adjust the output power and the temperature of the heat mixing with the temperature change of the heating object; it can also be arbitrarily shortened or It can be extended and used within a certain range, and has the advantages of good insulation performance, anti-aging performance, low-voltage operation, safety and reliability, good flexibility, easy installation, and convenient use and maintenance.
- Technical parameters Construction temperature: minimum -40 ℃.
- Structural diagram of self-controlling electric heating belt Thermal stability: 1000 times of on and off for 22 consecutive days, the heating value of the hot wire is maintained above 90%.
- Bending radius: 12.7mm at room temperature at 20°C, and 35.0mm at low temperature at -30°C.
- Insulation resistance: When the ambient temperature is 75°C, shake the meter with 2500VDC for 1 minute. The minimum insulation resistance (between the wire and the shield) is 100MQ.
- Working voltage: 12V, 24V, 36V, 110V, 220V Output power at 10°C: 10, 15, 25, 35, 45W/m.
Conductor Material | Tinned copper wire |
Ihe mkpuchi | PF |
Number of Conductors | 19*0.32, Twin Conductor |
Ngwa
Flame Retardant Explosion-Proof Type Self-Regulating Heating Cable
VERI manufactures self-regulating cables that provide safe and reliable heat tracing performance for freeze protection of pipes, valves, tanks, and similar applications.
Uru:
- Safe, no need thermostat
- Energy efficient
- Easy to install, cut to length on the job site
- Can be overlapped
- Automatically temperature control ed
- Eco-friendly, no emissions
Conductor Material | tinned copper |
Ihe mkpuchi | Thermoplastic |
Number of Conductors | 2 |
Agba | red,black or flexible color |
Voltage | 110-170v, 220v |
Ngwa
Piping, plumbing, safety showers, sprinkler systems, freeze protection, viscosity control, low to high-temperature maintenance, general locations, hazardous locations, heat tracing applications, warming, tank heating, drain de-icing, and driveway snow melting, and hot water systems.
Models | Voltage Level | Output Power (W/m) | Operating Environment | Certification Standards | Application |
SRL-5C | 120V/240V | 5W/m | Indoor/Outdoor | UL, CE, CSA | Pipe anti-freezing, roof snow melting |
SRF-10C | 120V/240V | 10W/m | Outdoor (inclement weather) | IEC 60079-30-1 | Industrial pipeline heat tracing, tank insulation |
SRH-15C (High temperature type) | 240V | 15W/m | High temperature environment (-50~200℃) | ATEX certification | Chemical piping, steam tracing |
120V/240V | 8W/m | Environmental requirement scenarios | RoHS, REACH | Indoor plumbing, underground heating |
Key Features of Self-Regulating Heating Cables
Self-regulating heating cables are designed to highlight their features and benefits through a segmented approach:
Energy Saving Effect
Automatic adjustment of the output power without additional control devices reduces energy waste.
High Reliability
Adapt to harsh environments (e.g., extremely cold regions), corrosion-resistant, UV-resistant, and resistant to mechanical damage.
Flexible Installation
Length can be customized, suitable for complex piping layouts and a variety of heating needs.
Multiple Certifications
Conforms to international standards such as UL, CSA, IEC, wdg., suitable for the global market.
Applications in Residential and Industrial Heating
Industrial Field
Petrochemical industry, storage tank heating and antifreeze protection.
Construction Field
Roof snow melting, downspout frost protection, floor heating.
Home Use
Freeze protection for indoor pipes and heating of garden water pipes.
High Temperature Self-Regulation Heating Cable for Pipe
This self-regulating heating cable adjusts the output power according to the ambient temperature. As the temperature increases, the resistance increases and the output power decreases. Conversely, when the temperature decreases, the resistance decreases and the cable generates more heat. Even when overlapped, the cables will not overheat or burn out.
ADVANTAGES
1. Energy fficient&Safety Assure
2. Easy to install, can be cut to any length (up to max circuit length)
3. No overheating or burnout.
4. Suitable for non-hazardous, hazardous, and corrosive environments.
5. Provide Complete accessories.
Ụdị | Power (W/M, at 10℃) | Maximum Tolerance Temperature | Maximum Maintain Temperature | Minimum Installation Temperature | Maximum Usage Length (based on 110/220V) |
Low Temperature | 10W/M 15W/M 25W/M 35W/M | 105℃ | 65℃±5℃ | -40℃ | 50/100m |
Medium Temperature | 35W/M 45W/M 50W/M 60W/M | 135℃ | 105℃±5℃ | -40℃ | 50/100m |
High Temperature | 35W/M 50W/M 60W/M | 205℃ | 120℃±5℃ | -30℃ | 50/100m |
Ọrụ Ọkachamara anyị
Asambodo ogo
Ngwaahịa ndị VERI Cables rụpụtara na-agbaso ụkpụrụ mba ụwa dịka GB, IEC, BS, NFC, ASTM, SITE, wdg. Ọzọkwa, anyị oru otu nwere ike inye USB customization ọrụ maka gị mkpa.
Ndepụta ndị ahịa
VRI na-enye ọrụ ndụmọdụ USB ọkachamara n'efu, otu nkwụsị ọrụ ngwọta ọrụ, na ngwọta nnyefe ngwaahịa ngwa ngwa.
Ụgbọ njem ọkachamara
VORI eriri’ ihe mgbaru ọsọ mbụ bụ iji hụ na nnyefe ngwa ngwa na nchekwa nke ngwaahịa ma na-enye nkwakọ ngwaahịa kacha mma na njem njem iji belata ndị ahịa’ njem na-akwụ nnukwu ụgwọ.
Nkwakọ ngwaahịa USB
A na-ebunye nkwakọ ngwaahịa VERI na reels osisi, igbe corrugated, na eriri igwe. A na-eji teepu nkwụnye onwe BOPP mechie ngwụcha ya na mkpuchi mkpuchi na-abụghị hygroscopic iji chebe njedebe eriri site na mmiri.. Anyị nwere ike ibipụta akara ngosi achọrọ n'èzí nke drum na ihe anaghị egbochi mmiri dịka onye ahịa chọrọ.