Igwe ọkụ anyanwụ
VERI Cable manufactures high-quality solar cable, which ensures it meets your special applications. As a professional power cable supplier, all of our cable products have GB, ISO, ASTM, AS, BS, CSA, SITE, IEC standards, and other international standards. Many types of waya na eriri address the requirements of solar power generation, nnyefe, na nkesa. With our extensive line of different voltage cable products, the general cable offers a complete solar energy solution. And our solar cables have also contributed to some hot area’s solar generation plants. N'ime ọtụtụ afọ, we have exported cables to many countries. And we will give the best solar cable price for you. Ya mere, welcome to contact us now.
Solar Cable Description and Specifications
Solar Power Cable
Solar power cables are widely used indoors and outdoors. And solar photovoltaic power sources usually require isolating switches or installation. N'ozuzu, they are rated for a temperature range of -40 degrees to 90 ogo. The maximum allowable DC voltage for most solar cables is 1.8kv. Because the solar power cable is flexible and is wrapped with a metal mesh. So they can avoid high voltage and improve shielding.
- Onye nduzi: Flexible stranded tinned copper conductor
- Mkpuchi: XLPE
- Sheath: XLPE / PVC / Customized
Ọkọlọtọ&Ntụaka:TUV 2PfG 1169/ IEC, TUV 2PfG 1990/ IEC standard
Ngwa
These cables are designed for connecting photovoltaic system components inside and outside of buildings and equipment with high mechanical requirements and extreme weather conditions.
Solar power cables are mainly used for photovoltaic power generation. Then they are intended for use in photovoltaic power supply systems. And similar applications as a free hanging, movable, fixed installation. And they are buried in the ground. ZMS solar cables are always used for indoor, outdoor, hazard explosion areas, industry, or agriculture. They are suitable for applications in equipment with protective insulation.
Product Parameters
NO. OF CORES ×NOMINAL CROSS SECTION | NO. OF STRANDING | NOMINAL CONDUCTOR DIAMETER | NOMINAL INSULATION THICKNESS | NOMINAL SHEATH THICKNESS | NOMINAL OVERALL DIAMATER | NOMINAL WEIGHT |
NO. ×MM² | – | MM | MM | MM | MM | KG/KM |
1×1.5 | 30/0.25 | 1.58 | 1.14 | 0.82 | 5.4 | 52 |
1×2.5 | 50/0.25 | 2.04 | 1.14 | 0.82 | 5.8 | 67 |
1×4.0 | 56/0.30 | 2.59 | 1.14 | 0.82 | 6.4 | 87 |
1×6.0 | 84/0.30 | 3.17 | 1.14 | 0.82 | 7.0 | 113 |
1×10 | 78/0.40 | 4.07 | 1.52 | 0.82 | 8.6 | 178 |
1×16 | 128/0.40 | 5.22 | 1.52 | 0.82 | 9.8 | 254 |
1×25 | 199/0.40 | 6.51 | 1.52 | 0.82 | 11.1 | 363 |
1×35 | 279/0.40 | 7.71 | 1.52 | 0.82 | 12.3 | 473 |
Uru
·Dual wall insulation. Electron beam cross-linked
·Excellent resistance to U.V, mmanụ, greases, oxygen and ozone
·Excellent resistance to abrasion
·Halogen free, ire ere, low toxicity
·Excellent flexibility and stripping performance
·High Voltage and Current carrying capacity
·TUV, CE approved
PV1-F 1.5mm2 XLPE Insulation Solar Cable
Rated temperature: -40 Degree to +90 Degrees
Voltage test on complete cable: 6.5KV AC ,15KV DC ,5min
The max temperature at conductor: +120 Degree
The expected period of use is 25 afọ (Ambient temperature-40+90Degree)
The permitted short circuit temperature refers to the period of 5s is +200 Degree
Bending radius: ≥4*Φ(D<8mm)≥6*Φ(D≥8MM)
Resistance against acid and alkaline solution: EN 60811-2-1
Cold bending test: EN60811-1-4
Ozone resistance at the complete cable: EN50396
Fire test: IEC 60332-1
Product Parameters
Cross Section | Onye nduzi Construction | Onye nduzi Stranded O.D (MM) | Mkpuchi I.D.(mm) | Jacket OD.(mm) | Conductor MAX Resistance |
1.5 | 30/0.25 | 1.58mm | 2.9 | 4.5 | 13.7 |
2.5 | 49/0.25 | 2.02mm | 3.4 | 5.0 | 8.21 |
4.0 | 56/0.30 | 2.60mm | 3.9 | 5.5 | 5.09 |
6.0 | 84/0.30 | 3.42mm | 4.7 | 6.5 | 3.39 |
10.0 | 84/0.40 | 4.56mm | 6.2 | 8.0 | 1.95 |
The Features of Solar Power Cable
Mbụ, solar power cables are often exposed to sunlight, and solar systems are often used for harsh environmental conditions. Such as high temperatures and ultraviolet radiation. Now, the variety of materials are PVC, rọba, and high-quality cross-link materials.
Nke abụọ, solar cables are flexible and design for fixed and mobile installations. About inside the outer casing of the solar cable, the positive and negative cables are double insulated.
And they run completely separate from each other. Then it reduces the risk of signal interference and further protects the quality. With this precaution, the likelihood of ground faults and short circuits is greatly reduced, improving the overall safety and efficiency.
And they are designed to withstand UV rays and weather and install outdoors without any problems. N'ezie, most of the time these cables are used outdoors. And they are exposed to harsh sunlight and harsh environments. Because of the shielding and casing on the solar cable, the wiring can run without the risk of electrical quality. Or the signals passing through the wires.
Ọrụ mara mma nke eriri VERI
Ahụmịhe mbupụ
Dị ka ọkachamara USB emeputa, Ebupụla ngwaahịa eriri anyị n'ọtụtụ mba n'oge gara aga 30 afọ, gụnyere USA, Canada, Spain, UK, Germany, France, Russia, Greece, Saudi Arabia, wdg. Na obodo ndị a, Ngwaahịa anyị USB na-ewu ewu nke ukwuu na ndị ahịa. Na kwa afọ, n'ihi àgwà ọma na ọrụ anyị, we would receive much good feedback from our customers.
Ọrụ eriri ahaziri ahazi
Usoro ọrụ omenala anyị gụnyere imewe, nha, na agba elu. Ọtụtụ agba ewu ewu dịkwa maka ịhọrọ. Anyị nwekwara ọkachamara na ịkwa akwa, ọmụmaatụ, anyị nwere ike ime polyethylene omenala (PE) na polyurethane (PUR) dị ka gị chọrọ. Anyị nwere ike ịnye azịza dabere na echiche gị. Biko kpọtụrụ anyị ka anyị nye anyị echiche gị.
Ụkpụrụ nyocha ogo siri ike
Veri Cable na-enye eriri ọkụ dịgasị iche iche dabere na usoro na mmasị onwe onye. And we provide all kinds of power cables, karịrị 100 usoro. Mgbe ahụ, to ensure the quality of the cables, anyị na-esi ọnwụ na-anwale ngwaahịa anyị otu ugboro n'oge.