Low Voltage Power Cable
Low-voltage cables manufactured by ZMS are used for used to transmit low-voltage signals, as opposed to traditional 110/220V AC cables. Low-voltage cables are usually made of copper or aluminum, with insulation including PVC, rubber, or fiberglass. VERI kejbils ta' vultaġġ baxx are suitable for transmission lines and distribution with a voltage of 0.6/1 KV. And we have various voltage cables with different voltage levels: kejbil ta 'vultaġġ għoli, medium voltage cable.
Types of Low Voltage Cables
Low Voltage Power Cable With Oil And Acid Resistance
ZMS produces this type of cable, the oil-resistant characteristics of the cable in the maximum degree of protection against static electricity. Oil and acid-resistant cable is a weak signal measuring cable, suitable for static prone, fuel pools, and other special working environments. With anti-static, oil-resistant, anti-tension, anti-bending characteristics. The minimum bending radius of the cable is not less than 5 times the diameter of the cable, the cable can withstand a maximum tensile force of 200kg, and the cable winding and bending several times more than 3000 times.
Features
100% complete length, no less but more.
99.99% oxygen-free copper, low resistance, high conductivity.
100% environmental material, fire retardant
Konduttur | Copper Core |
Materjal ta 'insulazzjoni | XLPE Insulation |
Voltage Type | LOW VOLTAGE <6kv |
Kulur | Customized Color |
Ġakketta | PVC PE XLPE |
Packaging Details | Carton, Wooden Box, Wooden Roll |
Certification | ISO9001/ISO14001 /OHSAS18001/CCC |
Model Number | YJV-1 |
Standard | IEC60502 |
0.6/1kV Low Voltage Underground CU XLPE SWA PVC 4 Core Armored Electric Copper Cable
Low-voltage cables refer to applications that require less infrastructure, including telephones, security wires, fire alarms, walkie-talkies, and the Internet. Also, the types of low-voltage cables can divide into AC voltage and DC voltage. Because as a professional LV cable manufacturer, we can meet all your needs.
The power cable is manufactured according to IEC 61089/BS 7870/DIN 48201/ASTM B399/BS EN50183/NFC33-209.
It is suitable to be laid in the power cable line with a rated voltage of 0.6/1kv (U0/U) for power transmission.
The low voltage power cable of ZMS cable has good electrical and mechanical properties, the best chemical resistance, environmental stress, and flame resistance. Barra minn hekk, its structure is simple, easy to use, and saves project costs. It is suitable for laying indoor, tunnel, canal, and underground laying areas.
Konduttur | Copper Core |
Materjal ta 'insulazzjoni | PVC |
Voltage Type | LOW VOLTAGE <6kv |
Kulur | Customized Color |
Ġakketta | PVC |
Packaging Details | Wooden Drums |
Certification | ISO9001, CCC |
Model Number | YJV32 YJVV22 |
Daqs | Customized Sizes |
Application:
Laid indoors, in tunnels, and pipes.
Able to withstand certain laying traction.
Not able to withstand mechanical external forces.
Single-core cable is not allowed to be laid in magnetic-made material pipes.
Operation Characteristic:
1. The maximum rated temperature
When the cable is used for a long time, the maximum working temperature of the core does not exceed 900C and the temperature of
the conductor shall not exceed, 2500C at a short circuit for 5 seconds.
2. Installation requirement
The installation of cables is not limited by the difference in elevation along the route. The ambient temperature should not be
less than 00C during installation. The permissible bending radius for cable shall be complied with the following regulations:
For single core: 20(D+d) +/_ 5%
For multicore: 15(D+d) +/_ 5%
(D–actual outer diameter of the cable; d–actual outer diameter of the conductor)
Single core cable used in AC circuits shall be without armor or use non-magnetic metal material armor and shall not be laid in
magnetic ducts.
0.6/1kV ABC —Overhead Conductors 7/19/37 wires Multiple strands XLPE Outdoor Aluminum Aerial
This is a kind of PVC, HEPE, and XLPE insulated aerial cable of copper core, qalba tal-aluminju, or aluminum alloy core. And they are suitable for overhead power lines of AC-rated voltage 0.6/1KV and below. The production standard for anti-flaming and fire-resistant cables is IEC 61089/BS 7870/DIN 48201/ASTM B399/BS EN50183/ NFC33-209. It is widely used in power transmission lines and electricity distribution lines. Because they have such good characteristics as simple structure and convenient maintenance. And low-cost large transmission capacity. They are also suitable for laying across rivers valleys and geographical places.
Main of Cable Features
2. Long-term allowable temperature of the cable: The allowable temperature of 105 Cable should not exceed 105℃, the allowable
temperature of other models should not exceed 70℃.
Konduttur | Aluminum |
Materjal ta 'insulazzjoni | XLPE |
Voltage Type | LOW VOLTAGE <6kv |
Kulur | Black |
Packaging Details | Wooden Drums |
Certification | ISO9001/ISO14001 /ISO45001/CE |
Daqs | Customized Sizes |
About VERICABLE
Veri Cable għandu diversi modi biex jipproteġi l-kejbils tiegħek, b'ippakkjar tat-tbaħħir b'saħħtu u professjonali u assigurazzjoni komprensiva. Qabel it-tbaħħir, tagħna kejbils huma ppakkjati f'rukkelli tal-injam u kojls tal-kaxxa korrugati. Waqt it-trasport, biex tipproteġi t-truf tal-kejbil mill-umdità, aħna nissiġillawhom b'tejp li jwaħħal waħdu BOPP u mhux igroskopiku.
Jekk ikun hemm problemi ta 'kwalità bħal ippakkjar bil-ħsara u ħsara fil-wiċċ tal-prodott fuq il-post meta l-oġġetti jiġu riċevuti, jekk il-merkanzija tkun ikkonfermata li hija vera, l-oġġetti ma jaqblux mal-ordni, u l-problemi ta 'kwalità misjuba mill-klijent waqt l-installazzjoni, proċess ta 'tqegħid u użu huma kkonfermati li huma l-problemi ta' kwalità tal-prodott innifsu, Jekk il-kunsinna ma tkunx skond ir-rekwiżiti tal-kuntratt, jekk jogħġbok ikkuntattja lill-kumpanija tagħna direttament.