MICC cables are also named mineral-insulated copper-clad cables. It is a kind of cable that uses annealed copper as a conductor, dense magnesium oxide as insulation, and annealed copper tube as a sheath. When necessary, a plastic outer sheath is extruded into the annealed copper sheath. Special requirements are smoke-free and halogen-free occasions. A low-smoke, halogen-free sheath can be added to the outside.
Since all materials of these cables are made of inorganic materials, it has some advantages that other cables cannot have. Such as fire prevention, large current carrying capacity, mechanical damage resistance, halogen-free non-toxic, explosion-proof, waterproof, corrosion resistance, long life, safety, overload resistance, high-temperature resistance, low cost, small bending radius, anti-termite, anti-mouse bite, copper protection features such as protective grounding wire.
BBTRZ is a flexible mineral insulated cable, commonly known as fireproof cable. It can withstand burning for 3 hours at a flame temperature of 950 degrees and a voltage of 1000V without breakdown. BBTRZ cable is the second generation product of mineral cable. In addition to the advantages of fire protection, explosion proof, temperature resistance and large carrying capacity of the first generation rigid (hard) mineral cable, It also has many unique features.
Conductor Material | Copper Core |
Insulation Material | XLPE Insulation |
Rated voltage | 0.6/1KV |
Standard | IEC60502 |
Size | Customized Size |
Certification | ISO9001/ISO14001 /OHSAS18001/CCC |
Jacket | PVC PE XLPE |
Feature | 200 Degree Heat Resistance |
Rated Temperature | 40-90—40-125 /Customized |
Specification(mm2) | Outer Diameter (mm) | Allowed continuous load capacity(A) | Allowable continuous soil loading(A) |
1*1.5 | 11 | 35 | 44 |
1*2.5 | 11.4 | 46 | 59 |
1*2.5 | 22.1 | 59 | 78 |
1*6 | 12.7 | 75 | 96 |
1*10 | 13.6 | 100 | 134 |
1*16 | 14.7 | 130 | 137 |
1*25 | 16.4 | 170 | 230 |
1*35 | 17.6 | 210 | 279 |
Mineral insulation is used to insulate thermocouple wires from each other and from the surrounding metal probe sheath. The sheath is filled with a highly compacted magnesium oxide powder that prevents the wires from coming into contact with each other beyond the fixed junction. The high density of the mineral powder gives the thermocouple fast response because it promotes rapid heat transfer between the wires and the sheath. Mineral insulation also helps protect thermocouple wires from environmental damage such as corrosion, prevents electrical interference, and allows the cable to remain flexible while maintaining its mechanical strength.
Type K mineral insulated thermocouples (Nichrome/Nickel Aluminum) are the most common type of thermocouple, offering accuracy and flexibility over a wide range of temperatures.
Cable Construction Specifications:
Conductor material | NiCr-NiSi, NiCrSi-NiSi, NiCr-Konstantan, Fe-Konstantan, Cu-Konstantan |
Core number | 2, 4 or 6 cores |
Sheath material | SS321(SS304), SS316, SS310, INCL600 |
Insulator | 99.6% high purity MgO |
Dia(mm) | from 0.25mm to 12.7mm |
Application | connecting with thermocouple and instrument machine |
Material | Type | Grade | Working temperature (deg) | Tolerance | Standard | |
Long Term | Short Term | |||||
NiCr-NiSi | K | 1 | -40~1100 | -40~1300 | ±1.5 deg | GB/T 2614-1998 |
2 | ±2.5 deg | |||||
NiCr-CuNi | E | 1 | -40~800 | -40~900 | ±1.5 deg | GB/T 4993-1998 |
2 | ±2.5 deg | |||||
Fe-Constantan | J | 1 | -40~600 | -40~800 | ±1.5 deg | GB/T 4994-1998 |
2 | ±2.5 deg | |||||
Cu-CuNi | T | 1 | -200~300 | -200~400 | ±0.5 deg | GB/T 2903-1998 |
Cable Application Parameters:
And we have a wide range of mineral insulated cable models. For example, YJV 1 core, YJV 2 cores, YJV 4+1 cores, YJV 3+1 cores, YJV 4 cores, YJV 5 cores, etc.
An intact end installed at the end of a mineral insulated cable, usually including a cap and a stuffing box or a combined end/stuffing box. Each cable requires a terminal.
When the copper sheath of the cable is used for grounding or the grounding of other electrical equipment connected with the copper sheath of the cable, a grounding sheet is required.
Used to connect conductors and control cabinet terminals or power supplies. It is composed of a press-fit nut, a press-fit oblique block, and a terminal body. There are two types of terminal blocks. One is the press-fit terminal block, which is suitable for connecting cables above 35mm2. Second, the crimping terminal is suitable for the connection of 6-25mm2 cables. Small size cables 4mm2 and below can be without terminal blocks.
When the cable length is not long enough, it is necessary to use the intermediate connector accessory. It is a device that connects two cables of the same specification into one cable. Cable does not need, heat shrinkable tubing, intermediate connecting terminal, fireproof porcelain column.