ARMORED ELECTRICAL CABLE

Armored Electric Cable

Armored Electric Cable does not have a specific model number, it refers to a large category in the classification of cables, VERI cable can be customized according to the customer to provide a variety of parameters and specifications for the appropriate armored cable products. VERI armored power cables are suitable for transmitting and distributing power in transmission and distribution systems from 0.6kv~35kv or lower voltages. It also prevents rodents from chewing through the armor which can cause power transmission problems. In addition to the above purposes, the addition of an armor layer to the cable enhances the mechanical protection properties such as tensile and compressive strength, and extends the service life.

Armored Cable Types and Sizes

Flexible Copper Oil Resistant PVC Armored Control Cable

The Armored Control Cable can be produced according to the standard GB9330-1988, IEC, DIN, and BS, and the factory can also manufacture the cables by other standards.

Rated voltage: 450/750V
Conductor: Copper wire /tinned-copper wire, Class1, Class2, Class5
Insulation: PVC /PE /XLPE
Cabling: multicore stranded
Shield(if required): Copper tape or CWS or Al-plastic tape with drain wire
Inner sheath (applicable if there is an armor layer): PVC/PE
Armour layer: Galvanized steel wire / Steel tape
Outer sheath: PVC/PE/LSHF
Other characteristics: Oil resistant, Flame retardant, Anti-corrosion, UV, etc.

Product Parameter Specification

Type
Name
Section Area(mm2)
No. of Core
Application Site
KVV
Copper Conductor,PVC Insulated and Sheathed Control Cable
0.75 1.0 1.5 2.5
2-16
Permanent installation indoors,in cable ditches or pipes
4 6
2-14
10
2-10
KVVP
Copper Conductor,PVC Insulated and Sheathed,Braiding Shielded Control Cable
0.75 1.0 1.5 2.5
2-61
Permanent installation indoors,in cable ditches or pipes where shielding is required
4 6
2-14
10
2-10
KVVP2
Copper Conductor,PVC Insulated and Sheathed,Copper-tape Screened Control Cable
0.75 1.0 1.5 2.5
4-10
Permanent installation indoors,in cable ditches or pipes where shielding is required
4 6
7-61
10
4-10
KVV22
Copper Conductor, PVC Insulated and Sheathed, Steel tape Armored Control Cable
0.75 1.0 1.5 2.5
7-61
Permanent installation indoors,in cable ditches,Be able to withstand stronger external mechanical force

Application

Armored Control Cable is suitable for the connection of control equipment and monitor instruments and is also used as power and connecting cables in mechanical engineering for tooling machinery, control units, production lines, transportation equipment, conveyor and assembly lines as well as in plant construction under the circumstance that the rated voltage is up to 450/750V AC.

STA Tube Flexible Armored Fiber Optic Cable

Steel armored cable fiber optic can be divided into indoor armored fiber optic cables and outdoor armored fiber optic cables according to the application of fiber optic cables. In addition, armored fiber optic cable can also be divided into interlocking armored fiber optic cable and corrugated armored fiber optic cable according to the different types of metal armor. Indoor armored fiber optic cable: indoor armored fiber optic cable includes single-layer armored and double-layer armored fiber optic cable.

Fiber Type: G.652D, G.657A1 or G.657A2 single mode fiber and OM1, OM2, OM3, OM4 mutimode fiber.

Features: 1. Mini diameter SUS spring tube reinforced ensures good crush resistance. 2. Kevlar strengthened provides good tensile strength. 3. LSZH Outer jacket complies with UL, RoHS.

Application:

1. Applied to the patch cord of the optical terminal.

2. Indoor outdoor for FTTH and optical distribution, connection between optical cable and communication equipment room.

MC Armored 12/2 Flexible Metal Clad Cable

VERI Type MC Armored Cable can be used for feeder and branch circuit lines as specified in NEC. The insulation wire core of type MC cable is XHHW-2, it can be used in dry and wet locations with the highest working temperature not exceeding 90. The rated voltage of type MC cable is 600V. The cable consists of three or four XLPE insulated phase cores plus one bare ground conductor. Interlocked aluminum armor tape is applied over all the cables. A PVC jacket is optional. MC cable with PVC jacket provides extra durability. long-term reliability and installation security.

Conductor: AA-8030 aluminum alloy conductors 
Insulation: Cross-linked polyethylene(XLPE) insulation
Armor: Interlock aluminum tape armor
Temperature Range: Temperature of 90 C in wet and dry locations
Environmental: Free of harmful heavy metals in compliance with RoHS
Voltage Rating:600Volt

 Cable Data Sheet:

Conductor Size( AWG,Kcmil)

Nominal insulation Thickness

Nominal Overall Diameter

Approx.Weight

inch

miles

lbs/1000ft

6-6-6-6

45

819

283

4-4-4-6

45

906

350

2-2-2-6

45

1016

446

Standard: ASTM-B,B-801 and B-836, UL standard 44 for XHHW-2, UL Standard 1569, RoHS environmental conductive requirement

Specifications:

The AA-8000 aluminum alloy conductor is applied in Type MC cable.
Its insulated core complies with the requirement of Type XHHW-2 in UL44.
Insulation material is cross-linked polyethylene(XLPE) with characteristics property, which can meet the FT2 level combustion test requirement.
MC cable, USA, UL & NEC standard, armored cable, metal-clad cable, AC cable, BX cable, TECK cable, interlocked armored cable.

Distinguished by Armor Layer Structure

STA Steel Tape Armored Cable

Conductor: Soft Bare / Tinned Copper
Insulation Material: PVC/PE/XLPE/RUBBER
Size: 1.25mm² ~325mm²
Core Number: 1 C~60C
Armoured Layer: Steel Wire
Jacket Metarial: PVC, PE, LSZH, RUBBER
Rated Voltage: 600V/1000V
Standard: IEC, BS, JIS, OEM, ODM
Application: Suitable for places that are prone to aging, harsh environments and acidic corrosion such as those containing chemicals.

Get A Free Quotation

Error: Contact form not found.

SWA Steel Wire Armored Cable

Conductor: Soft Bare / Tinned Copper
Size: 1.25mm² ~325mm²
Core Number: 1 C~60C
Insulation Material: PVC/PE/XLPE/RUBBER
Armoured Layer: Steel Wire
Jacket Material: PVC, PE, LSZH, RUBBER
Rated Voltage: 600V/1000V
Standard: IEC/BS/JIS/OEM/ODM
Application: Suitable for places that are prone to aging, harsh environments and acidic corrosion such as those containing chemicals.

Get A Free Quotation

Error: Contact form not found.

AWA ATA Aluminum Tape Aluminum Wire Armored Cable

Conductor: Soft Bare/Tinned Copper
Size: 1.25mm² ~325mm²
Core Nubmer: 1 C~60C
Insulation: PVC/PE/XLPE/RUBBER
Armoured Layer: Aluminium Wire/Aluminium Tape
Jacket Material: PVC, PE, LSZH, RUBBER
Rated Voltage: 600V/1000V
Standard: IEC, BS, JIS, OEM, ODM
Application: Suitable for places that are prone to aging, harsh environments and acidic corrosion such as those containing chemicals.

Get A Free Quotation

Error: Contact form not found.

Advantages of Armored Electrical Cables

Compared with the characteristics of unarmored and mineral insulated cables, armored cables have the following advantages:

Characteristics

Armored Cables

Unarmored Cables

MICC Cables

Mechanical damage resistance

High

Low

Extremely high

Corrosion resistance

Medium

Low

High

Weights

Medium

Light

Heavy

Applicable Scenarios

Underground, industrial sites

Indoor equipment connection

High-temperature, high-pressure places

Note: You need to choose the right cable for your needs, not blindly choose for the best.

FAQ

How long does armored electrical cable last?

VERI cable production of various types of armored cable life can be up to 20 years -40 years, under the premise of ensuring the quality of production, armored cable life is mainly affected by the use of the environment and operating conditions. For example, when laid outdoors, long-term exposure to extreme weather may shorten the life. Or long-term overload or over-temperature operation may lead to cable insulation aging, reducing cable life.

What is the minimum order quantity?

Typically, the minimum order quantity for all cables supported by VERI Cables is 500 meters, due to the fact that the weight of some cables, even in small quantities, can be very high and can lead to disturbances in transportation costs. We therefore recommend that you choose to buy locally for cable orders of less than 500 meters. You can still send us your high voltage cable inquiry.

How do I communicate with you?

On VERI Cable's website, you can contact us through inquiry box, email (sales@vericable.com), WhatsApp (+86 17303836349). We also support video conference with our customers and welcome them to visit us.

About VERI Cable After-Sales Service

First, Product Quality Commitment:

  1. There are quality records and testing data for the manufacture and testing of all cable products.
  2. For the inspection of product performance, we sincerely invite users to inspect the whole process and performance of the product in person. After the product is confirmed to be qualified, it will be packaged and shipped.

Second, the product price commitment:

  1. In order to ensure the high reliability of the product, the material selection of the system is made of domestic or high-quality products.
  2. Under the same competitive conditions, our company will sincerely provide you at an affordable price without reducing the technical performance of the product or changing the product components.
  3. Delivery time commitment:

Third, Product delivery time:

As far as possible according to user requirements, if there are special requirements that need to be completed in advance, our company can specially organize production and installation, and strive to meet user needs.

Fourth, after-sales service commitment:

  1. Service tenet: fast, decisive, accurate, thoughtful and thorough.
  2. Service objectives: service quality to win customer satisfaction.
  3. Service efficiency: If the equipment fails within the warranty period or outside the warranty period, after the supplier is notified, the maintenance personnel can reach the site and start maintenance within 24 hours.
  4. Service principle: The warranty period of cable products is twelve months. During the warranty period, the supplier will repair and replace the parts damaged due to quality reasons for free. If the parts are damaged outside the warranty period, the provided accessories will only charge the cost the cost of equipment damage caused by human factors of the buyer, and the accessories repaired or provided by the supplier are calculated at cost.