Armored Control Cable
Galvanized SWA Control Cable has the characteristics of moisture resistance, corrosion resistance, and damage resistance, and its excellent ability enables him to work normally in harsh conditions.
It can be laid in tunnels or cable trenches.
The steel wire armor layer of galvanized steel wire armored cable has high magnetic permeability and a good magnetic shielding effect.
It can be used to resist low-frequency interference and improve the anti-interference performance of the cable.
So this armored cable is suitable for industrial process automation applications, including instrument Cable, or signal transmission, measurement, control, and regulation.
Armored Control Cable Types
Galvanized Steel Braided Armored Control Cable
This product is manufactured according to the GB9330-88 standard. The low smoke low halogen flame retardant or low smoke zero halogen flame retardant control cable is manufactured according to the enterprise standard. The flame retardant property meets the requirements of GB / T17651 and GB / T17650. Flame-retardant control cables manufactured by corporate standards, flame retardant properties in line with GB / T18380.3 requirements.
This product is suitable for metallurgy, power, petrochemical, and other industrial and mining enterprises in the exchange rated voltage 450 / 750V and below electrical instrumentation, power distribution equipment, signal transmission, control, and measurement systems.
ype | Name | Applying bound |
KVV | Copper conductor PVC insulated and sheathed control cable | For laying indoors, in trenches, and in ducts for the fixed installation |
KVVP | Copper conductor PVC insulated & sheathed copper wire braiding screened control cable |
|
KVVP2 | Copper conductor PVC insulated and sheathed control cable with steel tape shied | For laying indoors, in trenches, and in ducts for the fixed installation |
KVV22 | Copper conductor PVC insulated and sheathed control cable with steel tape armored | For laying indoors, in trenches, in ducts, and in-ground, able to withstand heavier mechanical force, and for fixed installation |
KVVR | Copper conductor PVC insulated flexible control cable | For lying indoors, movable and flexible |
ZR-KVVP | Copper conductor PVC insulated & sheathed copper wire braiding screened flexible control cable | Fixed laying indoors with the capability of moving and screening |
ZR-KVV | Copper conductor PVC insulated and sheathed flame retardant control cable | For laying indoors, in trenches, in ducts, and for fixed installation. The cable should be flame retardant |
ZR-KVVP2 | Copper conductor PVC insulated and sheathed flame retardant control cable with steel tape shield | For laying indoors, in trenches, in ducts, and for fixed installation. The cable should be flame retardants |
ZR-KVV22 | Copper conductor PVC insulated and sheathed flame retardant control cable with steel tape armored | For laying indoors, in trenches, in ducts, and for fixed installation, the cable should be flame retardant and able to bear heavier external mechanical force and for fixed installation |
ZR-KVVR | Copper conductor PVC insulated and sheathed flame retardant flexible control cable | For laying indoors, the cable should be flame-retardant flexible, and movable |
USE REQUIREMENTS:
The max, long-term permitted operating temperature:70°C is for PVC insulated cable;80°C is for XLPE insulated cables. The laying temperature of cables should be not less than 0°C.
The allowable bending radius for cables: it should be not less than 6 times of outer diameter for non, armored or screened flexible cables, and it should be not less than 12 times of outer diameter for armored or copper tape screened cables.
Standard 600v Control Armored MC Power Cable
The product is suitable for connection in control, signal, protection circuit, and measuring system with rated power-frequency voltage 450/750V or 0.6/1KV.
CHARACTERISTICS:
1. The maximum permissible continuous operating temperature is 70℃
2. The lowest installation temperature of the cable is 0℃.
3. Permissible Min. Bending radius: not less than 6 times the completed cable diameter for unarmored cable; not less than 12 times the completed cable diameter for armored or copper tape screened cable; not less than 6 times the completed cable diameter for screened flexible cable.
FEATURES:
oil resistance、water resistance、abrasion resistance、acid and alkali resistance、various corrosive mass、aging resistance、non-combustion
The technical data of the standard teck90 600v control cable armored power cable MC cable is below for reference, any customized is available.
Type | Description | Main Application |
KYJV | Copper conductor XLPE insulated and PVC sheathed control cable | Laying indoors,in trenches, in ducts and directly in ground |
KYJVR | Copper conductor XLPE insulated and PVC sheathed | |
flexible control cable | ||
KYJVP | Copper conductor XLPE insulated and PVC sheathed control cable | Laying indoors,in trenches, in ducts directly in ground and other places that interference-resistance is requested. |
with copper tape lapping screen | ||
KYJVP2 | Copper conductor XLPE insulated and PVC sheathed flexible control | |
cable with braiding screen | ||
KYJVRP | Copper conductor XLPE insulated and PVC sheathed control cable | |
with copper tape longitudinal screen | ||
KYJVRP2 | Copper conductor XLPE insulated and PVC sheathed flexible control | |
cable with copper tape lapping screen |
KYJV22 | Copper conductor XLPE insulated and PVC sheathed control cable with steel tape armour | For flxed installation,laying indoors, in trenches and ducts,directly in ground where heavier mechanical force withstood |
KYJV32 | Copper conductor XLPE insulated and PVC sheathed control cable | For laying indoor, in tunnels, ducts, conduit and direct burial etc. Permanent place, able to bear greater mechanical force |
with steel wire armour | ||
KYJVP2-22 | Copper conductor XLPE insulated and PVC sheathed steel tape armored control cable with copper tape lapping screen | For fixed installation,laying indoors,in trenches and ducts,directly in ground where heavier mechanical force and interference resistance withstood. |
A VERI Cable vevőszolgálatról
Első, Termékminőségi elkötelezettség:
- Minden termék gyártásához és teszteléséhez minőségi feljegyzések és vizsgálati adatok állnak rendelkezésre kábeltermékek.
- A termék teljesítményének ellenőrzéséhez, Őszintén felkérjük a felhasználókat, hogy személyesen tekintsék meg a termék teljes folyamatát és teljesítményét. A termék minősítésének megerősítése után, be lesz csomagolva és kiszállítják.
Második, a termék árára vonatkozó kötelezettségvállalás:
- A termék magas megbízhatóságának biztosítása érdekében, a rendszer anyagválasztása hazai vagy minőségi termékekből készül.
- Ugyanolyan versenyfeltételek mellett, cégünk őszintén megfizethető áron kínálja Önt anélkül, hogy csökkentené a termék műszaki teljesítményét vagy megváltoztatná a termék összetevőit.
- Szállítási határidő vállalás:
Harmadik, A termék szállítási ideje:
Amennyire lehetséges, a felhasználói igényeknek megfelelően, ha vannak speciális követelmények, amelyeket előre ki kell tölteni, cégünk speciálisan megszervezi a gyártást és a telepítést, és törekedjünk a felhasználói igények kielégítésére.
Negyedik, vevőszolgálati kötelezettségvállalás:
- Szolgáltatási elv: gyors, döntő, pontos, átgondolt és alapos.
- Szolgáltatási célok: a szolgáltatás minősége az ügyfelek elégedettségének elnyerése érdekében.
- A szolgáltatás hatékonysága: Ha a berendezés meghibásodik a jótállási időn belül vagy azon kívül, a szállító értesítése után, a karbantartó személyzet elérheti a helyszínt és azon belül megkezdheti a karbantartást 24 óra.
- Szolgáltatási elv: A kábeltermékek jótállási ideje tizenkét hónap. A jótállási idő alatt, a minőségi okokból megsérült alkatrészeket a szállító ingyenesen megjavítja és kicseréli. Ha az alkatrészek a garanciális időszakon kívül sérültek, a szállított tartozékok csak a vevő emberi tényezői által okozott berendezéskárosodások költségét számítják fel, és a szállító által javított vagy biztosított tartozékokat önköltségi áron számítjuk ki.