BS 6622 MV кабели

BS 6622 Single Core Medium Voltage Cable

BS 6622 single core mv cable
BS6622 single core mv cable structure
Азыр сура
Колдонмо

Power single-core cable voltage range from 3.8/6.6KV to 19/33KV, frequency 50Hz. mainly used in power supply stations, indoor and outdoor laying, pipelines, туннельдер, mines, shafts, soil buried and submarine water, жана башкалар, and can withstand considerable pressure and mechanical forces, axial tensile force.

Structure

Дирижер

Plain annealed copper or aluminum conductors

Copper conductors are generally stranded (Part II) and aluminum conductors can be either stranded or solid (Part II).

Conductor Shield

Extruded semiconducting cross-linked composite layers are applied outside the conductor and completely cover it. The minimum thickness is 0.3 mm and the maximum resistivity shall not exceed 500 ohms at 90°C. Please contact ZMS for details.

Жылуулоо

Cross-linked polyethylene compounds

Сырткы кабык

PVC material/Medium Density Polyethylene (MDPE)/LSZH, the outer sheath color is usually black. The usual thickness of the outer sheath is 0.035D+1.0, with D indicating the diameter of the outer sheath in millimeters.

Physical Properties

Operating temperature: up to 90°C
Temperature range: -5°C (PVC jacket); -20°C (PE jacket)
Short-circuit temperature: 250°C (maximum duration of short-circuit not exceeding 5s)
Ийилген радиус: 12 x OD

Voltage Specification
Rated Voltage Uo/U Operating Voltage(Um) Testing Voltage (rms)
3.8/6.6KV 7.2KV 15KV
6.35/11KV 12KV 25.5KV
8.7/15KV 17.5KV 35KV
12.7/22KV 24KV 51KV
19/33KV 36KV 76KV

BS 6622 Three Core Medium Voltage Cable

three cores mv cable
3 cores mv cable structure
Азыр сура
Колдонмо

BS 6622 three-core cables are designed for power distribution from 3.8/6.6KV to 19/33KV at 50Hz.They are mainly used in a variety of applications such as power supply stations, indoor conduits, outdoor, buried and in water, and for the installation of cables to the industry, distribution stations, and power station cables.

Structure

Дирижер

Plain annealed copper or aluminum conductors

Copper conductors are generally stranded (Part II) and aluminum conductors can be either stranded or solid (Part II).

Conductor Shield

Extruded semiconducting cross-linked composite layers are applied outside the conductor and completely cover it. The minimum thickness is 0.3 mm and the maximum resistivity shall not exceed 500 ohms at 90°C. Please contact ZMS for details.

Жылуулоо

Cross-linked polyethylene compounds

Insulation Shield

PVC material/Medium Density Polyethylene (MDPE)/LSZH, the outer sheath color is usually black. The usual thickness of the outer sheath is 0.035D+1.0, with D indicating the diameter of the outer sheath in millimeters.

Inner Fill & Таңгактоо

The inner layer is generally made of waterproof material, unless the cable is to be longitudinally waterproofed. The inner layer is extruded or overlapped.

Physical Characteristics

Operating temperature: up to 90°C
Temperature range: -5°C (PVC jacket); -20°C (PE jacket)
Short-circuit temperature: 250°C (maximum duration of short-circuit not exceeding 5s)
Ийилген радиус: 15 x OD

Voltage Specification

Rated Voltage Uo/U

Operating Voltage(Um)

Testing Voltage (rms)

3.8/6.6KV

7.2KV

15KV

6.35/11KV

12KV

25.5KV

8.7/15KV

17.5KV

35KV

12.7/22KV

24KV

51KV

19/33KV

36KV

76KV

About BS 6622 Medium Voltage Cable

The most commonly used medium voltage cable under the BS6622 standard is the 11kv voltage, as it can be used for power networks, fixed installations in outdoor cable ducts or directly into the ground, and has a wide range of applications, and is indispensable for a variety of power pr ojects and urban electricity use.
In the range of medium voltage cables, the voltage range goes up to about 33kv and may also reach 35kv or 40kv depending on the standards of different countries.

What is the difference between the common 11kv and 33kv for the same medium voltage cable?

Different Voltage Ratings

  • 11kV cable: Rated voltage is generally 6/10kV or 6.35/11kV.
  • 33kV cables: the rated voltage is generally 19/33kV or 18/30kV.

The higher the voltage level, the higher the requirements for cable insulation, sheath and other materials.

Different Application Acenarios

11kV Cable

Mostly used for secondary power supply in urban distribution system, such as from the substation to the user distribution cabinet;

Factories, schools, small industrial parks and other medium-sized load places.

33kV cable

Used for backbone power transmission lines, e.g. from substations to multiple lower level transformers;

Suitable for long-distance, high-capacity power transmission, such as wind farms, photovoltaic power stations or large industrial load centers.

Differences in Structural Design

Due to the higher voltages they are subjected to, 33kV cables have a more complex construction, including thicker insulation (e.g. XLPE), tighter shielding systems (conductive shielding, metallic shielding), sheathing and so on, making them more mechanically protective.
11kV cables, on the other hand, have a simpler construction, but still include the basic conductor shielding, insulation and metal shielding.

11kV vs 33kV Cable Size

Due to the high voltage and thick insulation, 33kV cables are larger and heavier overall, requiring higher costs; installation is more complex in terms of space and labor, and often requires specialized tools and higher standards of construction conditions.

Example:

Item

11kV 1×240mm²

33kV 1×240mm²

Conductor Cross Section

240 мм²

240 мм²

Conductor Diameter

17.6 мм

17.6 мм

Insulation thickness

5.5 мм

8.0 мм

Cable weight

2.2 kg/m

2.8 kg/m

About ZMS Cable

ZMS Cable has more than 30 years of experience in manufacturing medium voltage cables, since 1990, our factory has been in the leading position in medium voltage cable technology, has supplied medium voltage cables for power projects in many countries around the world, and enjoys a good reputation in the Middle East, Southeast Asia, Africa, жана башкалар. ZMS Cable, as an excellent cable supplier, will always implement the principle of “customer first” to carry out the work to ensure that each order can be delivered without fail. ZMS Cable, as an excellent cable supplier, will carry out its work on the principle of “Customer First” to ensure that every order can be delivered without fail.

ZMS Cable Services

Сапат сертификаты
The products manufactured by VERI Cables comply with international standards such as GB, IEC, BS, NFC, ASTM, FROM, жана башкалар. Мындан тышкары, биздин техникалык команда сиздин муктаждыктарыңыз үчүн кабелдик ыңгайлаштыруу кызматтарын көрсөтө алат.

Кардарларды көзөмөлдөө
VERI акысыз профессионалдуу кабелдик консалтинг кызматтарын көрсөтөт, бирдиктүү долбоорду чечүү кызматтары, жана продуктуну тез жеткирүү чечимдери.

Профессионалдык транспорт
VERI кабелдери’ баштапкы максаты кардарларды азайтуу үчүн мыкты таңгактоо жана транспорттук чечимдерди камсыз кылуу, ошондой эле продуктуларды тез жана коопсуз жеткирүү болуп саналат’ транспорттук чыгымдар абдан чоң.

Кабелдик таңгактоо
VERI кабелдик таңгак жыгач катушкалар менен берилет, гофрленген кутулар, жана катушкалар. Кабелдин учтарын нымдуулуктан коргоо үчүн учтары BOPP өзү чаптама скотч жана гигроскопиялык эмес мөөр капкактары менен жабылган.. Биз кардардын талабы боюнча суу өткөрбөйт материал менен барабандардын сыртына керектүү логотип басып чыгара алабыз.

    Сураныч, төмөндөгү формага сурооңузду бериңиз.

    Электрондук почта*:

    аты*:

    Өлкө*:

    TEL*:

    Акысыз цитата*: