PANSARISTU OHJAUSKAAPELI
Galvanized SWA Control Cable has the characteristics of moisture resistance, korroosionkestävyys, and damage resistance, and its excellent ability enables him to work normally in harsh conditions.
It can be laid in tunnels or cable trenches.
The steel wire armor layer of galvanized steel wire armored cable has high magnetic permeability and a good magnetic shielding effect.
It can be used to resist low-frequency interference and improve the anti-interference performance of the cable.
So this armored cable is suitable for industrial process automation applications, including instrument Cable, or signal transmission, measurement, control, and regulation.
Armored Control Cable Types
Galvanized Steel Braided Armored Control Cable
This product is manufactured according to the GB9330-88 standard. The low smoke low halogen flame retardant or low smoke zero halogen flame retardant control cable is manufactured according to the enterprise standard. The flame retardant property meets the requirements of GB / T17651 and GB / T17650. Flame-retardant control cables manufactured by corporate standards, flame retardant properties in line with GB / T18380.3 requirements.
This product is suitable for metallurgy, power, petrochemical, and other industrial and mining enterprises in the exchange rated voltage 450 / 750V and below electrical instrumentation, power distribution equipment, signal transmission, control, and measurement systems.
ype | Nimi | Applying bound |
KVV | Copper conductor PVC insulated and sheathed control cable | For laying indoors, in trenches, and in ducts for the fixed installation |
KVVP | Copper conductor PVC insulated & sheathed copper wire braiding screened control cable |
|
KVVP2 | Copper conductor PVC insulated and sheathed control cable with steel tape shied | For laying indoors, in trenches, and in ducts for the fixed installation |
KVV22 | Copper conductor PVC insulated and sheathed control cable with steel tape armored | For laying indoors, in trenches, in ducts, and in-ground, able to withstand heavier mechanical force, and for fixed installation |
KVVR | Copper conductor PVC insulated flexible control cable | For lying indoors, movable and flexible |
ZR-KVVP | Copper conductor PVC insulated & sheathed copper wire braiding screened flexible control cable | Fixed laying indoors with the capability of moving and screening |
ZR-KVV | Copper conductor PVC insulated and sheathed flame retardant control cable | For laying indoors, in trenches, in ducts, and for fixed installation. The cable should be flame retardant |
ZR-KVVP2 | Copper conductor PVC insulated and sheathed flame retardant control cable with steel tape shield | For laying indoors, in trenches, in ducts, and for fixed installation. The cable should be flame retardants |
ZR-KVV22 | Copper conductor PVC insulated and sheathed flame retardant control cable with steel tape armored | For laying indoors, in trenches, in ducts, and for fixed installation, the cable should be flame retardant and able to bear heavier external mechanical force and for fixed installation |
ZR-KVVR | Copper conductor PVC insulated and sheathed flame retardant flexible control cable | For laying indoors, the cable should be flame-retardant flexible, and movable |
USE REQUIREMENTS:
The max, long-term permitted operating temperature:70°C is for PVC insulated cable;80°C is for XLPE insulated cables. The laying temperature of cables should be not less than 0°C.
The allowable bending radius for cables: it should be not less than 6 times of outer diameter for non, armored or screened flexible cables, and it should be not less than 12 times of outer diameter for armored or copper tape screened cables.
Standard 600v Control Armored MC Power Cable
The product is suitable for connection in control, signal, protection circuit, and measuring system with rated power-frequency voltage 450/750V or 0.6/1KV.
OMINAISUUDET:
1. The maximum permissible continuous operating temperature is 70℃
2. The lowest installation temperature of the cable is 0℃.
3. Permissible Min. Bending radius: not less than 6 times the completed cable diameter for unarmored cable; not less than 12 times the completed cable diameter for armored or copper tape screened cable; not less than 6 times the completed cable diameter for screened flexible cable.
FEATURES:
oil resistance、vedenkestävyys、abrasion resistance、acid and alkali resistance、various corrosive mass、aging resistance、non-combustion
The technical data of the standard teck90 600v control cable armored power cable MC cable is below for reference, any customized is available.
Tyyppi | Kuvaus | Main Application |
KYJV | Copper conductor XLPE insulated and PVC sheathed control cable | Laying indoors,in trenches, in ducts and directly in ground |
KYJVR | Copper conductor XLPE insulated and PVC sheathed | |
flexible control cable | ||
KYJVP | Copper conductor XLPE insulated and PVC sheathed control cable | Laying indoors,in trenches, in ducts directly in ground and other places that interference-resistance is requested. |
with copper tape lapping screen | ||
KYJVP2 | Copper conductor XLPE insulated and PVC sheathed flexible control | |
cable with braiding screen | ||
KYJVRP | Copper conductor XLPE insulated and PVC sheathed control cable | |
with copper tape longitudinal screen | ||
KYJVRP2 | Copper conductor XLPE insulated and PVC sheathed flexible control | |
cable with copper tape lapping screen |
KYJV22 | Copper conductor XLPE insulated and PVC sheathed control cable with steel tape armour | For flxed installation,laying indoors, in trenches and ducts,suoraan in ground where heavier mechanical force withstood |
KYJV32 | Copper conductor XLPE insulated and PVC sheathed control cable | For laying indoor, tunneleissa, kanavat, conduit and direct burial etc. Permanent place, able to bear greater mechanical force |
with steel wire armour | ||
KYJVP2-22 | Copper conductor XLPE insulated and PVC sheathed steel tape armored control cable with copper tape lapping screen | For fixed installation,laying indoors,in trenches and ducts,directly in ground where heavier mechanical force and interference resistance withstood. |
Tietoja VERI Cable -huoltopalvelusta
Ensimmäinen, Sitoumus tuotteen laatuun:
- Kaikkien valmistukseen ja testaukseen on olemassa laaturekisterit ja testaustiedot kaapelituotteet.
- Tuotteen suorituskyvyn tarkastukseen, kutsumme käyttäjiä vilpittömästi tarkastamaan koko prosessin ja tuotteen suorituskyvyn henkilökohtaisesti. Kun tuotteen kelpoisuus on vahvistettu, se pakataan ja lähetetään.
Toinen, tuotteen hintasitoumus:
- Tuotteen korkean luotettavuuden varmistamiseksi, järjestelmän materiaalivalikoima tehdään kotimaisista tai korkealaatuisista tuotteista.
- Samoilla kilpailuolosuhteilla, yrityksemme tarjoaa sinulle vilpittömästi edulliseen hintaan heikentämättä tuotteen teknistä suorituskykyä tai vaihtamatta tuotteen osia.
- Toimitusaikasitoumus:
Kolmas, Tuotteen toimitusaika:
Mahdollisuuksien mukaan käyttäjän vaatimusten mukaan, jos on erityisvaatimuksia, jotka on täytettävä etukäteen, Yrityksemme voi erityisesti järjestää tuotannon ja asennuksen, ja pyrimme vastaamaan käyttäjien tarpeisiin.
Neljäs, huoltopalvelusitoumus:
- Palveluperiaate: nopeasti, ratkaiseva, tarkka, harkittuja ja perusteellisia.
- Palvelun tavoitteet: palvelun laatu voittaa asiakastyytyväisyys.
- Palvelun tehokkuus: Jos laite vioittuu takuuajan sisällä tai takuuajan ulkopuolella, sen jälkeen, kun toimittajalle on ilmoitettu, huoltohenkilöstö pääsee paikalle ja aloittaa huollon sisällä 24 tuntia.
- Palveluperiaate: Kaapelituotteiden takuuaika on kaksitoista kuukautta. Takuuaikana, toimittaja korjaa ja vaihtaa laatusyistä vaurioituneet osat ilmaiseksi. Jos osat ovat vaurioituneet takuuajan ulkopuolella, toimitetut lisävarusteet veloittavat vain ostajan inhimillisten tekijöiden aiheuttamien laitevaurioiden kustannukset, ja toimittajan korjaamat tai toimittamat lisävarusteet on laskettu hankintahintaan.