CABLE njikwa ngwa agha
Galvanized SWA Control Cable has the characteristics of moisture resistance, corrosion resistance, and damage resistance, and its excellent ability enables him to work normally in harsh conditions.
It can be laid in tunnels or cable trenches.
Nke steel wire armor layer of galvanized steel wire armored cable has high magnetic permeability and a good magnetic shielding effect.
It can be used to resist low-frequency interference and improve the anti-interference performance of the cable.
So this armored cable is suitable for industrial process automation applications, including instrument Cable, or signal transmission, measurement, control, and regulation.
Armored Control Cable Types
Galvanized Steel Braided Armored Control Cable
This product is manufactured according to the GB9330-88 standard. The low smoke low halogen flame retardant or low smoke zero halogen flame retardant control cable is manufactured according to the enterprise standard. The flame retardant property meets the requirements of GB / T17651 and GB / T17650. Flame-retardant control cables manufactured by corporate standards, flame retardant properties in line with GB / T18380.3 requirements.
This product is suitable for metallurgy, power, petrochemical, and other industrial and mining enterprises in the exchange rated voltage 450 / 750V and below electrical instrumentation, power distribution equipment, signal transmission, control, and measurement systems.
ype | Aha | Applying bound |
KVV | Copper conductor PVC insulated and sheathed control cable | Maka ịtọba n'ime ụlọ, in trenches, and in ducts for the fixed installation |
KVVP | Copper conductor PVC insulated & sheathed copper wire braiding screened control cable |
|
KVVP2 | Copper conductor PVC insulated and sheathed control cable with steel tape shied | Maka ịtọba n'ime ụlọ, in trenches, and in ducts for the fixed installation |
KVV22 | Copper conductor PVC insulated and sheathed control cable with steel tape armored | Maka ịtọba n'ime ụlọ, in trenches, in ducts, and in-ground, able to withstand heavier mechanical force, and for fixed installation |
KVVR | Copper conductor PVC insulated flexible control cable | For lying indoors, movable and flexible |
ZR-KVVP | Copper conductor PVC insulated & sheathed copper wire braiding screened flexible control cable | Fixed laying indoors with the capability of moving and screening |
ZR-KVV | Copper conductor PVC insulated and sheathed flame retardant control cable | Maka ịtọba n'ime ụlọ, in trenches, in ducts, and for fixed installation. The cable should be flame retardant |
ZR-KVVP2 | Copper conductor PVC insulated and sheathed flame retardant control cable with steel tape shield | Maka ịtọba n'ime ụlọ, in trenches, in ducts, and for fixed installation. The cable should be flame retardants |
ZR-KVV22 | Copper conductor PVC insulated and sheathed flame retardant control cable with steel tape armored | Maka ịtọba n'ime ụlọ, in trenches, in ducts, and for fixed installation, the cable should be flame retardant and able to bear heavier external mechanical force and for fixed installation |
ZR-KVVR | Copper conductor PVC insulated and sheathed flame retardant flexible control cable | Maka ịtọba n'ime ụlọ, the cable should be flame-retardant flexible, and movable |
USE REQUIREMENTS:
The max, long-term permitted operating temperature:70°C is for PVC insulated cable;80°C is for XLPE insulated cables. The laying temperature of cables should be not less than 0°C.
The allowable bending radius for cables: it should be not less than 6 times of outer diameter for non, armored or screened flexible cables, and it should be not less than 12 times of outer diameter for armored or copper tape screened cables.
Standard 600v Control Armored MC Power Cable
The product is suitable for connection in control, signal, protection circuit, and measuring system with rated power-frequency voltage 450/750V or 0.6/1KV.
CHARACTERISTICS:
1. The maximum permissible continuous operating temperature is 70℃
2. The lowest installation temperature of the cable is 0℃.
3. Permissible Min. Bending radius: not less than 6 times the completed cable diameter for unarmored cable; not less than 12 times the completed cable diameter for armored or copper tape screened cable; not less than 6 times the completed cable diameter for screened flexible cable.
FEATURES:
mmanụ eguzogide、water resistance、abrasion resistance、acid and alkali resistance、various corrosive mass、aging resistance、non-combustion
The technical data of the standard teck90 600v control cable armored power cable MC cable is below for reference, any customized is available.
Ụdị | Description | Main Application |
KYJV | Copper conductor XLPE insulated and PVC sheathed control cable | Laying indoors,in trenches, in ducts and directly in ground |
KYJVR | Copper conductor XLPE insulated and PVC sheathed | |
eriri njikwa na-agbanwe agbanwe | ||
KYJVP | Copper conductor XLPE insulated and PVC sheathed control cable | Laying indoors,in trenches, in ducts directly in ground and other places that interference-resistance is requested. |
with copper tape lapping screen | ||
KYJVP2 | Copper conductor XLPE insulated and PVC sheathed flexible control | |
cable with braiding screen | ||
KYJVRP | Copper conductor XLPE insulated and PVC sheathed control cable | |
with copper tape longitudinal screen | ||
KYJVRP2 | Copper conductor XLPE insulated and PVC sheathed flexible control | |
cable with copper tape lapping screen |
KYJV22 | Copper conductor XLPE insulated and PVC sheathed control cable with steel tape armour | For flxed installation,laying indoors, in trenches and ducts,ozugbo in ground where heavier mechanical force withstood |
KYJV32 | Copper conductor XLPE insulated and PVC sheathed control cable | For laying indoor, in tunnels, ducts, conduit and direct burial etc. Permanent place, able to bear greater mechanical force |
with steel wire armour | ||
KYJVP2-22 | Copper conductor XLPE insulated and PVC sheathed steel tape armored control cable with copper tape lapping screen | For fixed installation,laying indoors,in trenches and ducts,directly in ground where heavier mechanical force and interference resistance withstood. |
About VERI Cable After-Sales Service
Mbụ, Product Quality Commitment:
- There are quality records and testing data for the manufacture and testing of all ngwaahịa USB.
- For the inspection of product performance, we sincerely invite users to inspect the whole process and performance of the product in person. After the product is confirmed to be qualified, it will be packaged and shipped.
Nke abụọ, the product price commitment:
- In order to ensure the high reliability of the product, the material selection of the system is made of domestic or high-quality products.
- Under the same competitive conditions, our company ga-eji ezi obi nye gị ọnụ ahịa dị ọnụ ala na-ebelata arụmọrụ teknụzụ nke ngwaahịa ahụ ma ọ bụ gbanwee akụrụngwa ngwaahịa.
- Ntinye oge nnyefe:
Nke atọ, Oge nnyefe ngwaahịa:
Dị ka o kwere mee dị ka onye ọrụ chọrọ, ma ọ bụrụ na e nwere ihe pụrụ iche chọrọ ka emechaa tupu oge eruo, ụlọ ọrụ anyị nwere ike ịhazi mmepụta na nrụnye pụrụ iche, ma gbalịsie ike izute mkpa onye ọrụ.
Nke anọ, nkwa ọrụ mgbe-ahịa:
- Usoro ọrụ: ngwa ngwa, kpebisie ike, ziri ezi, na-eche echiche na nke ọma.
- Ebumnuche ọrụ: àgwà ọrụ iji merie afọ ojuju ndị ahịa.
- Ịrụ ọrụ ọrụ: Ọ bụrụ na akụrụngwa daa n'ime oge ikike ma ọ bụ na-abụghị oge ikike, mgbe agwachara onye na-eweta ngwaahịa, ndị ọrụ nlekọta nwere ike iru saịtị wee malite ịrụzi n'ime 24 awa.
- Ụkpụrụ ọrụ: Oge ikike nke ngwaahịa USB bụ ọnwa iri na abụọ. N'ime oge ikike, onye na-eweta ya ga-edozi ma dochie akụkụ ndị mebiri emebi n'ihi ihe ndị dị mma n'efu. Ọ bụrụ na akụkụ ahụ mebiri emebi na-abụghị oge ikike, the provided accessories will only charge the cost the cost of equipment damage caused by human factors of the buyer, and the accessories repaired or provided by the supplier are calculated at cost.