Concentric & Split Cable
Concentric Cables are composed of single-core or multicore conductors, and there is an insulation layer between the multiple conductors, which can effectively prevent electromagnetic interference between the two conductors.
VERI produced Concentric Cables are typical of most cable insulation types. Concentric cables are often used as energy supply cables. Most common in power distribution, płyta, and street lighting areas.
Concentric Cable Popular Models
LV Concentric Cable
Dyrygent: Copper Class 2
Izolacja: XLPE / PCV
Rdzeń: Pojedynczy rdzeń
Wewnętrzna osłona kabla: PCV
Koncentryczna warstwa przewodząca: Miedź
Taśma kablowa: No-absorbent material or OEM
Opancerzony: AWA
Zewnętrzna osłona kabla: XLPE / PCV / PE / LSZH
Aluminum MV Concentric Cable
Standard: ASTM-B; ASTM-D; UL
Dyrygent: 8000 Series Aluminum Alloy
Izolacja: XLPE / PCV
Rdzeń: Pojedynczy rdzeń
Wewnętrzna osłona kabla: PCV
Koncentryczna warstwa przewodząca: Aluminium
Taśma kablowa: No-absorbent material or OEM
Opancerzony: AWA
Zewnętrzna osłona kabla: XLPE / PCV / PE / LSZH
LSZH Split Concentric Cable
Dyrygent: Aluminium / Przewodnik miedziany
Izolacja: XLPE
Rdzeń: Pojedynczy / Dwa / Trzy / Cztery rdzenie
Wewnętrzna osłona kabla: PCV
Koncentryczna warstwa przewodząca: Miedź / Aluminium
Taśma kablowa: No-absorbent Material or OEM
Zewnętrzna osłona kabla: LSZH
Three/Four Core Concentric Cable
Dyrygent: Aluminium / Przewodnik miedziany
Izolacja: XLPE
Rdzeń: Trzy / Cztery rdzenie
Wewnętrzna osłona kabla: PCV
Koncentryczna warstwa przewodząca: Copper/Aluminum
Taśma kablowa: No-absorbent Material or OEM
Zewnętrzna osłona kabla: XLPE / PCV / PE
Cable Application
This copper/aluminum conductor concentric cable is used in power distribution lines of rated voltage 600/1000V and below as the connecting cable from the power source to the electricity meter. Concentric conductor cables are suitable for use in dry and wet locations, directly underground or outdoors. The maximum working temperature is 70°C (PVC or PE insulation) or 90°C (XLPE insulation).
Armored concentric conductor cables have better mechanical strength. When buried in the ground, this increases their ability to withstand stresses, reduces damage caused by external forces, and ensures that cables and linked equipment work efficiently.
Cable Specifications
Number of cores: 1, 2, 3, 3+1, 3+2, 4, 4+1, 5 i tak dalej.
Typ | Rozmiar | Construction | |||||
AWG | Phase Conductor | XLPE(mm) | Neutral Conductor | UV-PVC(mm) | |||
NIE. | Tak. | Thick | NIE. | Tak. | Thick | ||
Bipolar | 12 | 7 | 0.78 | 1.14 | 39 | 0.321 | 1.14 |
10 | 7 | 0.98 | 1.14 | 25 | 0.511 | 1.14 | |
8 | 7 | 1.23 | 1.14 | 25 | 0.643 | 1.14 | |
6 | 7 | 1.55 | 1.14 | 25 | 0.813 | 1.14 | |
4 | 7 | 1.96 | 1.14 | 27 | 1.02 | 1.14 | |
Tripolar | 8 | 7 | 1.23 | 1.14 | 65 | 0.45 | 1.14 |
6 | 7 | 1.55 | 1.14 | 65 | 0.511 | 1.52 | |
4 | 7 | 1.96 | 1.14 | 65 | 0.643 | 1.52 | |
2 | 7 | 2.47 | 1.14 | 65 | 0.823 | 1.52 |
Typ | Rozmiar | Construction | |||||
mm2 | Phase Conductor | XLPE(mm) | Neutral Conductor | UV-PVC(mm) | |||
NIE. | Tak. | Thick | NIE. | Tak. | Thick | ||
Bipolar | 10 | 7 | 1.35 | 1.2 | 13 | 0.98 | 1.0 |
6 | 7 | 1.1 | 1.2 | 18 | 0.654 | 1.0 |
Jeśli nie wiesz jak wybrać produkty you need or don’t find the cable type and size you need on this page, Nie martw się. Skontaktuj się z nami i prześlij nam swoje wymagania, and we can help you choose the right cable. Możesz przekazać nam następujące informacje: napięcie kabla, materiał przewodnika, materiał izolacyjny i osłonowy, typ tarczy, rodzaj zbroi, itp. lub możesz zapewnić nam środowisko do instalacji kabli, wymagania aplikacji, itp. Będziemy Ci służyć całym sercem. Dostawca kabli VERI has a number of quality certifications: ISO 9000, ISO 9001, ISO14000, ISO14001, ISO18000, CE, IEC, licencjat, NFC, ASTM, Z, itp.
Doskonała obsługa kabla VERI
VERI Cable ma wiele sposobów ochrony kabli, z solidnym i profesjonalnym opakowaniem wysyłkowym oraz kompleksowym ubezpieczeniem. Przed wysyłką, nasz kable pakowane są w drewniane szpule i zwoje z tektury falistej. Podczas transportu, do ochrony końcówek kabli przed wilgocią, uszczelniamy je taśmą samoprzylepną BOPP i niehigroskopijną.
Jeśli występują problemy z jakością, takie jak uszkodzone opakowanie i uszkodzenie powierzchni produktu na miejscu w momencie odbioru towaru, jeżeli potwierdzona zostanie prawdziwość towaru, towar nie jest zgodny z zamówieniem, oraz problemy z jakością stwierdzone przez klienta podczas instalacji, Potwierdzono, że proces układania i użytkowania stanowią problemy z jakością samego produktu, Jeżeli dostawa nie jest zgodna z wymogami umowy, Proszę skontaktuj się z naszą firmą bezpośrednio.